共 31 条
Assessment of right ventricular volumes in hypoplastic left heart syndrome by real-time three-dimensional echocardiography: comparison with cardiac magnetic resonance imaging
被引:38
作者:
Bell, Aaron
[1
]
Rawlins, Debbie
[1
]
Bellsham-Revell, Hannah
[1
]
Miller, Owen
[1
]
Razavi, Reza
[2
]
Simpson, John
[1
]
机构:
[1] Evelina Childrens Hosp, Evelina London Childrens Hosp, London SE1 7EH, England
[2] Kings Coll London, Rayne Inst, Div Imaging Sci, London SE1 7EH, England
基金:
英国惠康基金;
英国工程与自然科学研究理事会;
关键词:
Hypoplastic left heart syndrome;
three-dimensional echocardiography;
Magnetic resonance imaging;
FUNCTIONAL SINGLE VENTRICLE;
EJECTION FRACTION;
RECONSTRUCTIVE SURGERY;
SURGICAL REPAIR;
NORMAL VALUES;
CHILDREN;
DISEASE;
QUANTIFICATION;
VALIDATION;
ACCURACY;
D O I:
10.1093/ehjci/jet145
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Accurate assessment of right ventricular (RV) volumes and function is important in patients with hypoplastic left heart syndrome (HLHS). We prospectively sought to determine the reproducibility of three-dimensional (3D) echocardiography and its agreement with cardiac magnetic resonance imaging (CMR) in HLHS. Twenty-eight patients underwent CMR followed immediately by transthoracic 3D echocardiography under general anaesthesia. Semi-automated border detection software was used to determine echocardiographic RV volumes. Inter- and intra-observer variability, correlation and levels of agreement between techniques were determined. The median age was 0.37 years (0.189.28 years) and weight 6.24 kg (3.4232.50 kg). Intra- and inter-observer variability was excellent for both techniques. Median (range) measurements for 3D echocardiography and CMR were; end-diastolic volume (EDV) 23.6 mL (6.563.2) and 30.6 mL (11.887.9), end-systolic volume (ESV) 12.6 mL (3.737.0) and 14.9 mL (5.833.9), stroke volume (SV) 11.2 mL (2.833.0) and 17.1 mL (6.054.1), ejection fraction (EF) 48.2 (31.264.9), and 56.5 (42.772.2). Correlation coefficients were r 0.85, 0.84, 0.83, and 0.74, respectively (P 0.01 for all). Volumetric data were expressed as a percentage of the echocardiographic volume to CMR volume. When compared with CMR, 3D echocardiography underestimated EDV, ESV and SV by 26.7 (SD 20.2), 10.6 (28.1), and 37.5 (20.1), respectively. The difference in volume appeared largest at low ventricular volumes. EF was 8.3 (7.3) lower by 3D echocardiography compared with CMR. Both 3D echocardiography and CMR volumes appear highly reproducible. Measurements obtained by 3D echocardiography are significantly lower than those obtained by CMR, with wide limits of agreement such that these two methods cannot be used inter-changeably.