Intrarater reliability and agreement of a modified Closed Kinetic Chain Upper Extremity Stability Test

被引:22
作者
Degot, Matthieu [1 ]
Blache, Yoann [1 ]
Vigne, Gregory [2 ]
Jure, Dimitri [1 ,2 ]
Borel, Florent [3 ]
Neyton, Lionel [3 ,4 ]
Rogowski, Isabelle [1 ]
机构
[1] Univ Lyon, Lab Interuniv Biol Motricite EA 7424, UFRSTAPS, 27-29 Blvd 11 Novembre 1918, F-69622 Villeurbanne, France
[2] Athlet France, 4 Rue Jean Sarrazin, F-69008 Lyon, France
[3] Ctr Orthoped Santy, Fifa Med Ctr Excellence, 24 Ave Paul Santy, F-69008 Lyon, France
[4] Ramsay Gen Sante, Hop Prive Jean Mermoz, 55 Ave Jean Mermoz, F-69008 Lyon, France
关键词
Hand spacing; CKCUEST; Shoulder stability; Muscular endurance index; TEST-RETEST RELIABILITY; FUNCTIONAL PERFORMANCE; STRENGTH;
D O I
10.1016/j.ptsp.2019.04.017
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: To assess the reliability of a modified procedure for Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST). Design: Intra- and intersession reliability and agreement; Setting: Clinical. Participants: Twenty-seven asymptomatic athletes. Main outcome measures: The modifications (m-CKCUEST) in CKCUEST procedure consisted in hand spacing at one half arm-span, and to complete the three regular-series of 15 s exertion by performing a fourth 1-min series during which the number of touches was counted every 15 s. The intra- and inter session reliability and agreement were assessed for the numbers of touches in order to produce two outcome measures: m-CKCUEST score and muscular endurance index. Results: The most reliable m-CKCUEST score was obtained when averaging the numbers of touches of the second and third sets (Intraclass Coefficient of Correlation(3,k); ICC = 0.92). Good reliability was found for muscular endurance index computed when dividing the one-half number of touches counted during the last 30 s of 1-min set, by the m-CKCUEST score calculated above (ICC = 0.86). Conclusions: The m-CKCUEST allowed the production of two reliable outcome measures, which assessed the upper limb stability and the muscular endurance. Such outcomes may be used in a follow-up to assess performance or rehabilitation level. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:44 / 48
页数:5
相关论文
共 21 条
[1]   Alternative methods of normalising EMG during cycling [J].
Albertus-Kajee, Yumna ;
Tucker, Ross ;
Derman, Wayne ;
Lambert, Michael .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2010, 20 (06) :1036-1043
[2]   Upper-Extremity Functional Performance Tests: Reference Values for Overhead Athletes [J].
Borms, Dorien ;
Cools, Ann .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2018, 39 (06) :433-441
[3]   Comparison of muscle activation using various hand positions during the push-up exercise [J].
Cogley, RM ;
Archambault, TA ;
Fibeger, JF ;
Koverman, MM ;
Youdas, JW ;
Hollman, JH .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2005, 19 (03) :628-633
[4]  
de Oliveira VMA, 2017, INT J SPORTS PHYS TH, V12, P125
[5]  
ELLENBECKER T, 2000, ORTHOP PHYS THER CLI, V9, P219
[6]   Test-retest reliability of the closed kinetic chain upper extremity stability test: A clinical field test [J].
Goldbeck, TG ;
Davies, GJ .
JOURNAL OF SPORT REHABILITATION, 2000, 9 (01) :35-45
[7]  
Ismail M. M., 2014, Annals of Physical and Rehabilitation Medicine, V57, P353, DOI 10.1016/j.rehab.2014.06.002
[8]   Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed [J].
Kottner, Jan ;
Audige, Laurent ;
Brorson, Stig ;
Donner, Allan ;
Gajewski, Byron J. ;
Hrobjartsson, Asbjorn ;
Roberts, Chris ;
Shoukri, Mohamed ;
Streiner, David L. .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2011, 64 (01) :96-106
[9]   Reliability and validity of the closed kinetic chain upper extremity stability test [J].
Lee, Dong-Rour ;
Kim, Laurentius Jongsoon .
JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (04) :1071-1073
[10]   Reliability of knee extension and flexion measurements using the Con-Trex isokinetic dynamometer [J].
Maffiuletti, Nicola A. ;
Bizzini, Mario ;
Desbrosses, Kevin ;
Babault, Nicolas ;
Munzinger, Urs .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2007, 27 (06) :346-353