Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist

被引:9
|
作者
Park, Hee Jin [1 ]
Lee, So Yeon [1 ]
Kang, Kyung A. [1 ]
Kim, Eun Young [1 ]
Shin, Hun Kyu [2 ]
Park, Se Jin [2 ]
Park, Jai Hyung [2 ]
Kim, Eugene [2 ]
机构
[1] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Radiol, Sch Med, Seoul, South Korea
[2] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Orthopaed Surg, Sch Med, Seoul, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2018年 / 91卷 / 1084期
关键词
FAST-FIELD ECHO; T2-WEIGHTED SEQUENCES; CRUCIATE LIGAMENT; KNEE MRI; 3.0; T; DIAGNOSIS; COMPLEX; INJURY; JOINT;
D O I
10.1259/bjr.20170604
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare image quality of three-dimensional volume isotropic T-2 weighted fast spin echo (3D VISTA) and two-dimensional (2D) T-2 weighted images (T2WI) for evaluation of triangular fibrocartilage (TFC) and to investigate whether 3D VISTA can replace 2D T2 WI in evaluating TFC injury. Methods: This retrospective study included 69 patients who received wrist MRIs using both 2D T-2 WI and 3D VISTA techniques for assessment of wrist pathology, including TFC injury. Two radiologists measured the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) of the two sequences. The anatomical identification score and diagnostic performance were independently assessed by two interpreters. The diagnostic abilities of 3D VISTA and 2D T-2 WI were analysed by sensitivity, specificity and accuracy for diagnosing TFC injury using surgically or clinically confirmed diagnostic reference standards. Results: 17 cases (25%) were classified as having TFC injury. 2 cases (12%) were diagnosed surgically, and 15 cases (88%) were diagnosed by physical examination. 52 cases (75%) were diagnosed as having intact TFC. 8 of these cases (15%) were surgically confirmed, while the others were diagnosed by physical examination and clinical findings. The 3D VISTA images had significantly higher SNR and CNR values for the TFC than 2D T2WI images. The scores of 3D VISTA's total length, full width and sharpness were similar to those of 2D T-2 WI. We were unable to find a significant difference between 3D VISTA and 2D T-2 WI in the ability to diagnose TFC injury. Conclusion: 3D VISTA image quality is similar to that of 2D T-2 WI for TFC evaluation and is also excellent for tissue contrast. 3D VISTA can replace 2D images in TFC injury assessment. Advances in knowledge: 3D VISTA image quality is similar to that of 2D T-2 WI for TFC evaluation and is also excellent for tissue contrast. 3D VISTA can replace 2D images in TFC injury assessment.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Reliability of fast-spin echo T2-weighted three-dimensional sequences to predict endoscopic third ventriculocisternostomy patency in children
    Lefevre, Etienne
    Caudron, Yohan
    Beccaria, Kevin
    Levy, Raphael
    Dangouloff-Ros, Volodia
    Blauwblomme, Thomas
    Boddaert, Nathalie
    CHILDS NERVOUS SYSTEM, 2023, 39 (04) : 937 - 942
  • [32] Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T
    Wolff, Andrew B.
    Pesce, Lorenzo L.
    Wu, Jim S.
    Smart, L. Ryan
    Medvecky, Michael J.
    Haims, Andrew H.
    SKELETAL RADIOLOGY, 2009, 38 (01) : 21 - 29
  • [33] Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T
    Andrew B. Wolff
    Lorenzo L. Pesce
    Jim S. Wu
    L. Ryan Smart
    Michael J. Medvecky
    Andrew H. Haims
    Skeletal Radiology, 2009, 38 : 21 - 29
  • [34] Hyperacute cerebral infarction in a cat model: Comparison of fast spin echo T2 weighted image, diffusion weighted image and MR spectroscopy
    Seo, J
    Kang, H
    Jeong, G
    Kim, JK
    Park, J
    Kim, Y
    RADIOLOGY, 1999, 213P : 273 - 273
  • [35] Automated Analysis of Hip Joint Cartilage Combining MR T2 and Three-Dimensional Fast-Spin-Echo Images
    Chandra, Shekhar S.
    Surowiec, Rachel
    Ho, Charles
    Xia, Ying
    Engstrom, Craig
    Crozier, Stuart
    Fripp, Jurgen
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (01) : 403 - 413
  • [36] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Zhang, Jing
    Chen, Lang
    Wang, Qiu-Xia
    Liu, Rong
    Zhu, Wen-Zhen
    Luo, Xin
    Peng, Li
    Xiong, Wei
    NEURORADIOLOGY, 2015, 57 (04) : 357 - 365
  • [37] Isotropic three-dimensional fast spin-echo Cube magnetic resonance dacryocystography: comparison with the three-dimensional fast-recovery fast spin-echo technique
    Jing Zhang
    Lang Chen
    Qiu-Xia Wang
    Rong Liu
    Wen-Zhen Zhu
    Xin Luo
    Li Peng
    Wei Xiong
    Neuroradiology, 2015, 57 : 357 - 365
  • [38] Evaluation of diagnostic value and T2-weighted three-dimensional isotropic turbo spin-echo (3D-SPACE) image quality in comparison with T2-weighted two-dimensional turbo spin-echo (2D-TSE) sequences in lumbar spine MR imaging
    Hossein, Jomleh
    Fariborz, Faeghi
    Mehrnaz, Rasteh
    Babak, Rafiei
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2019, 6 : 36 - 41
  • [39] T2-weighted three-dimensional fast spin-echo MR in inflammatory peripheral facial nerve palsy
    Sartoretti-Schefer, S
    Kollias, S
    Wichmann, W
    Valavanis, A
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (03) : 491 - 495
  • [40] Three-dimensional fast-recovery fast spin-echo MRCP: Comparison with two-dimensional single-shot fast spin-echo techniques
    Sodickson, A
    Mortele, KJ
    Barish, MA
    Zou, KH
    Thibodeau, S
    Tempany, CMC
    RADIOLOGY, 2006, 238 (02) : 549 - 559