Comparison of two-dimensional fast spin echo T2 weighted sequences and three-dimensional volume isotropic T2 weighted fast spin echo (VISTA) MRI in the evaluation of triangular fibrocartilage of the wrist

被引:9
|
作者
Park, Hee Jin [1 ]
Lee, So Yeon [1 ]
Kang, Kyung A. [1 ]
Kim, Eun Young [1 ]
Shin, Hun Kyu [2 ]
Park, Se Jin [2 ]
Park, Jai Hyung [2 ]
Kim, Eugene [2 ]
机构
[1] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Radiol, Sch Med, Seoul, South Korea
[2] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Orthopaed Surg, Sch Med, Seoul, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2018年 / 91卷 / 1084期
关键词
FAST-FIELD ECHO; T2-WEIGHTED SEQUENCES; CRUCIATE LIGAMENT; KNEE MRI; 3.0; T; DIAGNOSIS; COMPLEX; INJURY; JOINT;
D O I
10.1259/bjr.20170604
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare image quality of three-dimensional volume isotropic T-2 weighted fast spin echo (3D VISTA) and two-dimensional (2D) T-2 weighted images (T2WI) for evaluation of triangular fibrocartilage (TFC) and to investigate whether 3D VISTA can replace 2D T2 WI in evaluating TFC injury. Methods: This retrospective study included 69 patients who received wrist MRIs using both 2D T-2 WI and 3D VISTA techniques for assessment of wrist pathology, including TFC injury. Two radiologists measured the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) of the two sequences. The anatomical identification score and diagnostic performance were independently assessed by two interpreters. The diagnostic abilities of 3D VISTA and 2D T-2 WI were analysed by sensitivity, specificity and accuracy for diagnosing TFC injury using surgically or clinically confirmed diagnostic reference standards. Results: 17 cases (25%) were classified as having TFC injury. 2 cases (12%) were diagnosed surgically, and 15 cases (88%) were diagnosed by physical examination. 52 cases (75%) were diagnosed as having intact TFC. 8 of these cases (15%) were surgically confirmed, while the others were diagnosed by physical examination and clinical findings. The 3D VISTA images had significantly higher SNR and CNR values for the TFC than 2D T2WI images. The scores of 3D VISTA's total length, full width and sharpness were similar to those of 2D T-2 WI. We were unable to find a significant difference between 3D VISTA and 2D T-2 WI in the ability to diagnose TFC injury. Conclusion: 3D VISTA image quality is similar to that of 2D T-2 WI for TFC evaluation and is also excellent for tissue contrast. 3D VISTA can replace 2D images in TFC injury assessment. Advances in knowledge: 3D VISTA image quality is similar to that of 2D T-2 WI for TFC evaluation and is also excellent for tissue contrast. 3D VISTA can replace 2D images in TFC injury assessment.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Three-dimensional isotropic fast spin-echo MR lymphangiography of T1-weighted and intermediate-weighted pulse sequences in patients with lymphoedema
    Jeon, J. Y.
    Lee, S. H.
    Shin, M. J.
    Chung, H. W.
    Lee, M. H.
    CLINICAL RADIOLOGY, 2016, 71 (01) : E56 - E63
  • [22] Diagnostic performance of wrist magnetic resonance (MR) arthrography: comparison of three-dimensional isotropic T1 weighted fast spin-echo MR arthrography and two-dimensional MR arthrography
    Oh, Eunsun
    Yoon, Young C.
    Park, Min J.
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1071):
  • [23] 3D sagittal T2 weighted fast spin echo imaging of the cervical spine with axial reformations: Comparison to gradient-echo sequences
    Jones, KC
    Johnson, CE
    Destian, S
    Kagetsu, NJ
    RADIOLOGY, 1998, 209P : 202 - 202
  • [24] APPLICATION OF FAST SPIN-ECHO T(2)-WEIGHTED IMAGING FOR EXAMINATION OF THE NEUROCRANIUM - COMPARISON WITH THE CONVENTIONAL T(2)-WEIGHTED SPIN-ECHO SEQUENCE
    SIEWERT, C
    HOSTEN, N
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01): : 44 - 50
  • [25] T2-weighted MRI of the uterus: Fast spin echo vs. breath-hold fast spin echo
    Ascher, SM
    O'Malley, J
    Semelka, RC
    Patt, RH
    Rajan, S
    Thomasson, D
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (03): : 384 - 390
  • [26] FAST MRI WITH T2-WEIGHTED SPIN-ECHO SEQUENCES BY VARYING THE FLIP ANGLE
    SCHUBEUS, P
    SANDER, B
    SCHORNER, W
    DEIMLING, M
    TOSCH, U
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 155 (03): : 272 - 276
  • [27] Three-dimensional T1-weighted gradient echo is a suitable alternative to two-dimensional T1-weighted spin echo for imaging the canine brain
    Fleming, Kathryn L.
    Maddox, Thomas W.
    Warren-Smith, Christopher M. R.
    VETERINARY RADIOLOGY & ULTRASOUND, 2019, 60 (05) : 543 - 551
  • [28] Brachial plexus assessment with three-dimensional isotropic resolution fast spin echo MRI: comparison with conventional MRI at 3.0 T
    Tagliafico, A.
    Succio, G.
    Neumaier, C. E.
    Baio, G.
    Serafini, G.
    Ghidara, M.
    Calabrese, M.
    Martinoli, C.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1014): : E110 - E116
  • [29] T2-weighted MR imaging of the uterus: Comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences
    Gryspeerdt, S
    Van Hoe, L
    Bosmans, H
    Baert, AL
    Vergote, I
    Marchal, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 211 - 215
  • [30] Reliability of fast-spin echo T2-weighted three-dimensional sequences to predict endoscopic third ventriculocisternostomy patency in children
    Etienne Lefevre
    Yohan Caudron
    Kevin Beccaria
    Raphael Levy
    Volodia Dangouloff-Ros
    Thomas Blauwblomme
    Nathalie Boddaert
    Child's Nervous System, 2023, 39 : 937 - 942