A cymbal transducer for power ultrasonics applications

被引:32
|
作者
Bejarano, Fernando [1 ]
Feeney, Andrew [1 ]
Lucas, Margaret [1 ]
机构
[1] Univ Glasgow, Sch Engn, Glasgow G12 8QQ, Lanark, Scotland
基金
英国工程与自然科学研究理事会;
关键词
Cymbal transducer; Nonlinear behaviour; Power ultrasonics; ACTUATORS;
D O I
10.1016/j.sna.2014.02.024
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The flextensional class V 'cymbal' transducer has been widely adopted for low power ultrasonics applications, exhibiting high output displacement for low input energy, compared to a single ceramic, when used as an actuator. Despite its performance benefits, the original designs of cymbal transducers have inherent drawbacks for high power ultrasonics applications that require much higher output displacements. Asymmetries introduced during the fabrication process reduce the efficiency of the transducer, and degradation of the bonding layer between the end-caps and the electroactive material can alter the vibration response and ultimately lead to failure. A new design of the cymbal transducer is therefore proposed that delivers high output displacements. A comparison is presented between a cymbal based on the original design configuration and a new cymbal, to demonstrate the effects of input voltage levels on the dynamic characteristics and vibration response of the two different transducers. For the first cymbal the end-caps are directly bonded to the piezoceramic disc using a commercial non-conductive epoxy. The second cymbal incorporates a metal ring bonded to the outer edge of the piezoceramic disc to improve the mechanical coupling with the end-caps, thereby enhancing the operational capability of the device at higher voltages, allowing for excitation of higher output displacements by removing the problems associated with failure in the epoxy layer. This design is demonstrated to be particularly suitable for power ultrasonics applications such as miniature surgical devices, for example as drilling and cutting devices for orthopaedics procedures. (C) 2014 The Authors. Published by Elsevier B.V.
引用
收藏
页码:182 / 189
页数:8
相关论文
共 50 条
  • [1] Dynamics characterisation of cymbal transducers for power ultrasonics applications
    Feeney, Andrew
    Bejarano, Fernando
    Lucas, Margaret
    44TH ANNUAL SYMPOSIUM OF THE ULTRASONIC INDUSTRY ASSOCIATION, (UIA 44TH SYMPOSIUM) AND 45TH ANNUAL SYMPOSIUM OF THE ULTRASONIC INDUSTRY ASSOCIATION, (UIA 45TH SYMPOSIUM), 2016, 87 : 29 - 34
  • [2] Finite element modeling and design of cymbal transducers for power ultrasonics applications
    Bejarano, F.
    Lucas, M.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1567 - 1570
  • [3] Smart Cymbal Transducers with Nitinol End-Caps for Power Ultrasonics Applications
    Lucas, Margaret
    Feeney, Andrew
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1432 - 1435
  • [4] Cymbal transducer array for hydrophone applications
    Li, DH
    Yao, X
    FERROELECTRICS, 2001, 263 (1-4) : 1431 - 1436
  • [5] Size and material effects on cymbal transducer for actuator applications
    Dogan, A
    Uzgur, E
    FERROELECTRICS, 2006, 331 : 53 - 63
  • [6] Simulation Analysis on Cymbal Transducer
    Yang, Qingfeng
    Wang, Peng
    Wang, Yuhong
    Zhang, Kai
    MECHATRONICS AND INFORMATION TECHNOLOGY, PTS 1 AND 2, 2012, 2-3 : 140 - 143
  • [7] Computational analysis on cymbal transducer
    Uzgur, AE
    Dogan, A
    Suvaci, E
    Newnham, RE
    CHEMICAL ENGINEERING COMMUNICATIONS, 2003, 190 (5-8) : 853 - 860
  • [8] Tailoring the Q of cymbal transducer
    Dogan, A
    Yazici, ZO
    Uzgur, E
    EURO CERAMICS VIII, PTS 1-3, 2004, 264-268 : 1305 - 1308
  • [9] Applications of Power Ultrasonics in Engineering
    Lucas, M.
    Cardoni, A.
    McCulloch, E.
    Hunter, G.
    MacBeath, A.
    ADVANCES IN EXPERIMENTAL MECHANICS VI, 2008, 13-14 : 11 - 20
  • [10] Mechanical and electrical characteristics of cymbal transducer
    WANG Guangcan ZHANG Jin TIAN Wenjie LIN Guoguang LIAN Guandong ZHANG Fuxue (Yunnan University Kunming 650091) (Sensors Institute
    Chinese Journal of Acoustics, 2005, (04) : 354 - 369