A cylindrical Penning trap for capture, mass selective cooling, and bunching of radioactive ion beams

被引:121
|
作者
RaimbaultHartmann, H
Beck, D
Bollen, G
Konig, M
Kluge, HJ
Schark, E
Stein, J
Schwarz, S
Szerypo, J
机构
[1] GSI DARMSTADT,D-64220 DARMSTADT,GERMANY
[2] UNIV MAINZ,INST PHYS,D-6500 MAINZ,GERMANY
[3] UNIV WARSAW,INST EXPT PHYS,PL-00681 WARSAW,POLAND
关键词
Penning trap; mass separation; ion cooling; ion accumulation;
D O I
10.1016/S0168-583X(96)01067-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Penning trap ion accumulator, cooler, and buncher for low-energy ion beams has been developed for the ISOLTRAP mass spectrometer at ISOLDE/CERN. A cylindrical electrode configuration is used for the creation of a nested trapping potential. This is required for efficient accumulation of externally produced ions and for high-mass selectivity by buffer gas cooling. The design goal of a mass resolving power of about 1 x 10(5) has been achieved, Isobar separation has been demonstrated for radioactive rare-earth ion beams delivered by the ISOLDE on-line mass separator.
引用
收藏
页码:378 / 382
页数:5
相关论文
共 50 条
  • [41] Atomic mass of 6Li using a Penning-ion-trap mass spectrometer
    Heavner, T.P., 2001, American Institute of Physics Inc. (64):
  • [42] Mass Selective Ion Transfer and Accumulation in Ion Trap Arrays
    Wang, Yuzhuo
    Zhang, Xiaohua
    Zhai, Yanbing
    Jiang, You
    Fang, Xiang
    Zhou, Mingfei
    Deng, Yulin
    Xu, Wei
    ANALYTICAL CHEMISTRY, 2014, 86 (20) : 10164 - 10170
  • [43] Cooling of short-lived, radioactive, highly charged ions with the TITAN cooler Penning trap Status and perspectives
    Simon, V. V.
    Delheij, P.
    Dilling, J.
    Ke, Z.
    Shi, W.
    Gwinner, G.
    HYPERFINE INTERACTIONS, 2011, 199 (1-3): : 151 - 159
  • [44] Resistive cooling of ions' center-of-mass energy in a Penning trap on millisecond time scales
    Kiffer, Markus
    Ringleb, Stefan
    Stoehlker, Thomas
    Vogel, Manuel
    PHYSICAL REVIEW A, 2024, 109 (03)
  • [45] Mass Measurement of Single Intact Nanoparticles in a Cylindrical Ion Trap
    Zhang, Ning
    Zhu, Kai
    Xiong, Caiqiao
    Jiang, Yurong
    Chang, Huan-Cheng
    Nie, Zongxiu
    ANALYTICAL CHEMISTRY, 2016, 88 (11) : 5958 - 5962
  • [46] Low-vacuum cylindrical ion trap mass spectrometry
    Jiang, Peihe
    Zhou, Zhiquan
    Wu, Zhongjie
    Zhao, Zhanfeng
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2018, 46 (06) : 614 - 627
  • [47] Analytical performance of a miniature cylindrical ion trap mass spectrometer
    Riter, LS
    Peng, YA
    Noll, RJ
    Patterson, GE
    Aggerholm, T
    Cooks, RG
    ANALYTICAL CHEMISTRY, 2002, 74 (24) : 6154 - 6162
  • [48] Development of Microfabricated Cylindrical Ion Trap Mass Spectrometer Arrays
    Chaudhary, Ashish
    van Amerom, Friso H. W.
    Short, R. Timothy
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2009, 18 (02) : 442 - 448
  • [49] Advances in precision, resolution, and separation techniques with radioactive, highly charged ions for Penning trap mass measurements
    Ettenauer, S.
    Simon, M. C.
    Macdonald, T. D.
    Dilling, J.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 349 : 74 - 80
  • [50] A high intensity electron beam ion trap for charge state boosting of radioactive ion beams
    Marrs, RE
    Slaughter, DR
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, PTS 1 AND 2, 1999, 475 : 322 - 325