Imaging islets labeled with magnetic nanoparticles at 1.5 Tesla

被引:128
作者
Tai, Joo Ho
Foster, Paula
Rosales, Alma
Feng, Biao
Hasilo, Craig
Martinez, Violetta
Ramadan, Soha
Snir, Jonatan
Melling, C. W. James
Dhanvantari, Savita
Rutt, Brian
White, David J. G.
机构
[1] Univ Western Ontario, Robarts Res Inst, Dept Transplantat, London, ON N6G 2V4, Canada
[2] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5C1, Canada
[3] Hlth Sci Ctr, Human Islet Transplantat Program, London, ON, Canada
[4] Hlth Sci Ctr, Dept Pathol, London, ON, Canada
[5] Univ Western Ontario, Lawson Hlth Res Inst, Dept Med Biophys & Med, London, ON N6A 3K7, Canada
关键词
D O I
10.2337/db06-0393
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We have developed a magnetic resonance imaging (MRI) technique for imaging Feridex (superparamagnetic iron oxide [SPIO])-labeled islets of Langerhans using a standard clinical 1.5-Tesla (T) scanner and employing steady-state acquisition imaging sequence (3DFIESTA). Both porcine and rat islets were labeled with SPIO by a transfection technique using a combination Of POIY-L-lysine and electroporation. Electron microscopy demonstrated presence of SPIO particles within the individual islet cells, including P-cells and particles trapped between cell membranes. Our labeling method produced a transfection rate of 860 pg to 3.4 ng iron per islet, dependent on the size of the islet. The labeling procedure did not disrupt either the function or viability of the islets. In vitro 3DFIESTA magnetic resonance images of single-labeled islets corresponded with their optical images. In vivo T2*-weighted scan using 1.5 T detected as few as 200 SPIO-labeled islets transplanted under rat kidney capsule, which correlated with immunohistochemistry of the transplant for insulin and iron. Ex vivo 3DFIESTA images of kidneys containing 200, 800 or 2,000 SPIO-labeled islet isografts showed good correlation between signal loss and increasing numbers of islets. These data provide evidence that islets can be labeled with SPIO and imaged using clinically available 1.5T MRI.
引用
收藏
页码:2931 / 2938
页数:8
相关论文
共 42 条
[1]   Incompatibility between human blood and isolated islets of Langerhans - A finding with implications for clinical intraportal islet transplantation? [J].
Bennet, W ;
Sundberg, B ;
Groth, CG ;
Brendel, MD ;
Brandhorst, D ;
Brandhorst, H ;
Bretzel, RG ;
Elgue, G ;
Larsson, R ;
Nilsson, B ;
Korsgren, O .
DIABETES, 1999, 48 (10) :1907-1914
[2]   Expression of complement regulatory proteins on islets of langerhans:: A comparison between human islets and islets isolated from normal and hDAF transgenic pigs' [J].
Bennet, W ;
Björkland, A ;
Sundberg, B ;
Brandhorst, D ;
Brendel, MD ;
Richards, A ;
White, DJ ;
Nilsson, B ;
Groth, CG ;
Korsgren, O .
TRANSPLANTATION, 2001, 72 (02) :312-319
[3]  
Bennet W, 2000, TRANSPLANTATION, V69, P711
[4]   RAT PANCREATIC-ISLET PRETREATMENT WITH ANTI-MHC CLASS-II MONOCLONAL-ANTIBODIES AND CULTURE - INVITRO MLIC TEST RESPONSE DOES NOT PREDICT ISLET ALLOGRAFT SURVIVAL [J].
BRETZEL, RG ;
FLESCH, BK ;
BRENNENSTUHL, G ;
GREINER, I ;
HERING, BJ ;
WOEHRLE, M ;
FEDERLIN, K .
ACTA DIABETOLOGICA, 1993, 30 (01) :49-56
[5]   Neurotransplantation of magnetically labeled oligodendrocyte progenitors: Magnetic resonance tracking of cell migration and myelination [J].
Bulte, JWM ;
Zhang, SC ;
van Gelderen, P ;
Herynek, V ;
Jordan, EK ;
Duncan, ID ;
Frank, JA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (26) :15256-15261
[6]   Rat islet isolation yield and function are donor strain dependent [J].
de Groot, M ;
de Haan, BJ ;
Keizer, PPM ;
Schuurs, TA ;
van Schilfgaarde, R ;
Leuvenink, HGD .
LABORATORY ANIMALS, 2004, 38 (02) :200-206
[7]   Normal T-cell response and in vivo magnetic resonance imaging of T cells loaded with HIV transactivator-peptide-derived superparamagnetic nanoparticles [J].
Dodd, CH ;
Hsu, HC ;
Chu, WJ ;
Yang, PG ;
Zhang, HG ;
Mountz, JD ;
Zinn, K ;
Forder, J ;
Josephson, L ;
Weissleder, R ;
Mountz, JM ;
Mountz, JD .
JOURNAL OF IMMUNOLOGICAL METHODS, 2001, 256 (1-2) :89-105
[8]   Detection of single mammalian cells by high-resolution magnetic resonance imaging [J].
Dodd, SJ ;
Williams, M ;
Suhan, JP ;
Williams, DS ;
Koretsky, AP ;
Ho, C .
BIOPHYSICAL JOURNAL, 1999, 76 (01) :103-109
[9]  
Dousset V, 1999, MAGNET RESON MED, V41, P329, DOI 10.1002/(SICI)1522-2594(199902)41:2<329::AID-MRM17>3.0.CO
[10]  
2-Z