The Glycemic Effect of Liraglutide Evaluated by Continuous Glucose Monitoring in Persons with Type 2 Diabetes Receiving Dialysis

被引:11
|
作者
Bomholt, Tobias [1 ]
Idorn, Thomas [2 ]
Knop, Filip K. [2 ,3 ,4 ,5 ]
Jorgensen, Morten B. [1 ]
Ranjan, Ajenthen G. [5 ]
Resuli, Marsela [6 ]
Hansen, Pernille M. [7 ]
Borg, Rikke [8 ]
Persson, Frederik [5 ]
Feldt-Rasmussen, Bo [1 ,3 ]
Hornum, Mads [1 ,3 ]
机构
[1] Univ Copenhagen, Rigshosp, Dept Nephrol, Blegdamsvej 9, DK-2100 Copenhagen OE, Denmark
[2] Univ Copenhagen, Gentofte Hosp, Ctr Clin Metab Res, Hellerup, Denmark
[3] Univ Copenhagen, Fac Hlth & Med Sci, Dept Clin Med, Copenhagen, Denmark
[4] Univ Copenhagen, Novo Nordisk Fdn Ctr Basic Metab Res, Fac Hlth & Med Sci, Copenhagen, Denmark
[5] Steno Diabet Ctr Copenhagen, Gentofte, Denmark
[6] Univ Copenhagen, Hillerd Hosp, Dept Nephrol, Hillerod, Denmark
[7] Univ Copenhagen, Herlev Hosp, Dept Nephrol, Herlev, Denmark
[8] Univ Copenhagen, Roskilde Hosp, Dept Nephrol, Roskilde, Denmark
关键词
Chronic hemodialysis; Diabetic nephropathy; Peritoneal dialysis; Liraglutide; Type; 2; diabetes; GLP-1; MANAGEMENT;
D O I
10.1159/000510613
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Aims: The aim of this study was to evaluate the effect of liraglutide treatment on glucose variability and the risk of hypoglycemia by continuous glucose monitoring (CGM) in persons with type 2 diabetes (T2D) and dialysis-dependent end-stage renal disease (ESRD). Materials and Methods: We assessed CGM data from a previous trial where 24 persons with T2D and dialysis-dependent ESRD were allocated (1:1) to 12 weeks of double-blinded treatment with liraglutide (titrated to maximum tolerable dose up to 1.8 mg) or placebo as an add-on to preexisting antidiabetic treatment. CGM (Ipro2(R); Medtronic) was performed for up to 7 days at baseline and at weeks 2, 6, and 10. A linear mixed model was used to compare the 2 study arms. Results: A CGM was worn at baseline by 12 persons in the liraglutide group and 10 in the placebo group (7 and 9 completed week 10, respectively). Glycated hemoglobin A(1c) (p = 0.81) and glucose variability was similar between the groups (standard deviation, p = 0.33; coefficient of variation, p = 0.16). Comparing baseline and week 10, the number of hypoglycemic events (glucose values between <3.9 and 3.0 mmol/L) increased in the liraglutide group compared with the placebo group (p = 0.02). The occurrence of hypoglycemic events below 3.0 mmol/L was similar between the groups (p = 0.36). Conclusions: In the present cohort of persons with T2D and dialysis-dependent ESRD, liraglutide treatment increased the risk of hypoglycemic events as compared to placebo (no difference was found for hypoglycemic events below 3.0 mmol/L). The majority of participants were co-treated with insulin.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 50 条
  • [1] Cardiometabolic Risk Factors in Type 2 Diabetes Persons Evaluated by Continuous Glucose Monitoring
    Morosanu, Andreea
    Morosanu, Magdalena
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2024, 153
  • [2] Can the Use of Continuous Glucose Monitoring Improve Glycemic Control in Patients with Type 1 and 2 Diabetes Receiving Dialysis?
    Bomholt, Tobias
    Kofod, Dea
    Norgaard, Kirsten
    Rossing, Peter
    Feldt-Rasmussen, Bo
    Hornum, Mads
    NEPHRON, 2023, 147 (02) : 91 - 96
  • [3] Continuous glucose monitoring in persons with type 2 diabetes not using insulin
    Cowart, Kevin
    Updike, Wendy H.
    Franks, Rachel
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (11) : 1049 - 1055
  • [4] Analysis of the effect of liraglutide on glycemic variability in patients with type 2 diabetes
    Xing, Yuling
    Chen, Jinhu
    Zhao, Liying
    Ma, Huijuan
    ENDOCRINE JOURNAL, 2020, 67 (04) : 455 - 468
  • [5] Hemoglobin A1c and Fructosamine Evaluated in Patients with Type 2 Diabetes Receiving Peritoneal Dialysis Using Long-Term Continuous Glucose Monitoring
    Bomholt, Tobias
    Feldt-Rasmussen, Bo
    Butt, Rizwan
    Borg, Rikke
    Sarwary, Mir Hassan
    Elung-Jensen, Thomas
    Almdal, Thomas
    Knop, Filip K.
    Norgaard, Kirsten
    Ranjan, Ajenthen G.
    Larsson, Anders
    Rix, Marianne
    Hornum, Mads
    NEPHRON, 2022, 146 (02) : 146 - 152
  • [6] Characteristics of Continuous Glucose Monitoring Metrics in Persons with Type 1 and Type 2 Diabetes Treated with Multiple Daily Insulin Injections
    Hallstrom, Sara
    Hirsch, Irl B.
    Ekelund, Magnus
    Sofizadeh, Sheyda
    Albrektsson, Henrik
    Dahlqvist, Solveig
    Svensson, Ann-Marie
    Lind, Marcus
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (06) : 425 - 433
  • [7] Continuous Glucose Monitoring and Glycemic Control in Patients With Type 2 Diabetes Mellitus and CKD
    Presswala, Lubaina
    Hong, Susana
    Harris, Yael
    Romao, Isabela
    Zhang, Meng
    Jhaveri, Kenar D.
    Sakhiya, Vipul
    Fishbane, Steven
    KIDNEY MEDICINE, 2019, 1 (05) : 281 - 287
  • [8] Alternate glycemic markers reflect glycemic variability in continuous glucose monitoring in youth with prediabetes and type 2 diabetes
    Chan, Christine L.
    Pyle, Laura
    Kelsey, Megan M.
    Newnes, Lindsey
    Baumgartner, Amy
    Zeitler, Philip S.
    Nadeau, Kristen J.
    PEDIATRIC DIABETES, 2017, 18 (07) : 629 - 636
  • [9] Improved glycemic control with teneligliptin in patients with type 2 diabetes mellitus on hemodialysis: Evaluation by continuous glucose monitoring
    Wada, Noritsugu
    Mori, Katsuhito
    Nakagawa, Chie
    Sawa, Jun
    Kumeda, Yasuro
    Shoji, Tetsuo
    Emoto, Masanori
    Inaba, Masaaki
    JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2015, 29 (08) : 1310 - 1313
  • [10] Effects of Continuous Glucose Monitoring on Glycemic Control in Type 2 Diabetes: A Systematic Review and Meta-Analysis
    Kong, Seung-Yeon
    Cho, Mi-Kyoung
    HEALTHCARE, 2024, 12 (05)