The onset of fretting at the head-stem connection in hip arthroplasty is affected by head material and trunnion design under simulated corrosion conditions

被引:17
作者
Rowan, Fiachra E. [1 ]
Wach, Amanda [2 ]
Wright, Timothy M. [2 ]
Padgett, Douglas E. [1 ]
机构
[1] Hosp Special Surg, Adult Reconstruct & Joint Replacement, 535 East 70th St, New York, NY 10021 USA
[2] Hosp Special Surg, Dept Biomech, 535 E 70th St, New York, NY 10021 USA
关键词
corrosion; trunnion; taper; trunnionosis; mechanically assisted crevice corrosion; LOCAL TISSUE-REACTIONS; TAPER INTERFACE; CERAMIC HEADS; NECK TAPER; IN-VITRO; METAL; PROSTHESES; RETRIEVAL; FAILURE; REPLACEMENT;
D O I
10.1002/jor.23813
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Mechanically assisted crevice corrosion (MACC) is a mechanism for trunnion damage in total hip arthroplasties (THAs). Retrieval studies have shown reduced MACC-related damage for ceramic heads compared with cobalt-chromium (CoCr) heads. We propose that ceramic heads demonstrate fretting at higher cyclic compressive loads than CoCr heads on titanium alloy trunnions in a simulated corrosion model. A closed electrochemical chamber was used to measure fretting current onset loads for two modern titanium alloy trunnions (Zimmer 12/14 and Stryker V-40) in which trunnion failure has been reported. Ceramic and CoCr alloy 36+0mm heads were impacted on each trunnion and cyclically loaded at 3Hz with increasing magnitude from 100 to 3,400N for 540 cycles. Onset load was the cyclic compressive load at which the slope of the average fretting current increased significantly. A CoCr head with V40 trunnion demonstrated the lowest onset load (1,400N), while the V40 trunnion with a ceramic head showed the highest onset load (2,200N). Significant differences occurred in average fretting current between head materials for V40 trunnions (p<0.001) at loads over 2,000N. CoCr-12/14 and ceramic-12/14 couples demonstrated similar onset loads (2,000N). All head-trunnion combinations showed cyclical fretting response to loading at 100N. Head material composition was observed to increase fretting at the taper junction but the effect was taper geometry dependent. Using ceramic heads may reduce the phenomena of trunnion fretting and corrosion but the effect of both trunnion geometry and metallurgy warrants further investigation. Statement of clinical significance: Trunnion corrosion may occur with titanium alloy stems regardless of the head material used. (c) 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1630-1636, 2018.
引用
收藏
页码:1630 / 1636
页数:7
相关论文
共 25 条
  • [1] Taper Design, Head Material, and Manufacturer Affect the Onset of Fretting Under Simulated Corrosion Conditions
    Woon, Colin Y. L.
    Wach, Amanda
    Wright, Timothy M.
    Padgett, Douglas E.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (04) : 1117 - 1122
  • [2] Head-stem trunnion dissociation due to corrosion in total hip arthroplasty
    Whitehouse, Michael R.
    ANNALS OF TRANSLATIONAL MEDICINE, 2017, 5 (17)
  • [3] Catastrophic Femoral Head-Stem Trunnion Dissociation Secondary to Corrosion
    Ko, Laura Matsen
    Chen, Antonia F.
    Deirmengian, Gregory K.
    Hozack, William J.
    Sharkey, Peter F.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (16) : 1400 - 1404
  • [4] Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty?
    Del Balso, Christopher
    Teeter, Matthew G.
    Tan, Sok Chuen
    Howard, James L.
    Lanting, Brent A.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (10) : 2332 - 2336
  • [5] A computational approach to fretting wear prediction at the head-stem taper junction of total hip replacements
    English, Russell
    Ashkanfar, Ariyan
    Rothwell, Glynn
    WEAR, 2015, 338 : 210 - 220
  • [6] Mixing of Head-Stem Components in Total Hip Arthroplasty
    Mueller, Ulrike
    Panzram, Benjamin
    Braun, Steffen
    Sonntag, Robert
    Kretzer, J. Philippe
    JOURNAL OF ARTHROPLASTY, 2018, 33 (03) : 945 - 951
  • [7] Femoral head material loss at the head-neck junction in total hip arthroplasty: the effect of head size, stem material and stem offset
    Valente, Giuseppe
    Lanting, Brent
    MacDonald, Steven
    Teeter, Matthew G.
    Van Citters, Douglas
    Howard, James
    HIP INTERNATIONAL, 2019, 29 (06) : 647 - 651
  • [8] Design and Performance Evaluation of a Novel Spiral Head-Stem Trunnion for Hip Implants Using Finite Element Analysis
    Soliman, Md Mohiuddin
    Chowdhury, Muhammad E. H.
    Islam, Mohammad Tariqul
    Musharavati, Farayi
    Mahmud, Sakib
    Hafizh, Muhammad
    Ayari, Mohamed Arselene
    Khandakar, Amith
    Alam, Mohammad Kaosar
    Nezhad, Erfan Zal
    MATERIALS, 2023, 16 (04)
  • [9] Assessing Taper Geometry, Head Size, Head Material, and Their Interactions in Taper Fretting Corrosion of Retrieved Total Hip Arthroplasty Implants
    El-Zein, Zein S.
    Gehrke, Corinn K.
    Croley, J. Sawyer
    Siljander, Matthew P.
    Mallow, Murphy A.
    Flierl, Michael A.
    Verner, James J.
    Baker, Erin A.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (07) : S386 - +
  • [10] The Relationship Between Cobalt/Chromium Ratios and the High Prevalence of Head-Stem Junction Corrosion in Metal-on-Metal Total Hip Arthroplasty
    Hothi, Harry S.
    Berber, Reshid
    Whittaker, Robert K.
    Blunn, Gordon W.
    Skinner, John A.
    Hart, Alister J.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (05) : 1123 - 1127