Transcatheter Atrial Septal Defect Closure in Children with and without Fluoroscopy: A Comparison

被引:16
作者
Ackermann, S. [1 ,2 ]
Quandt, D. [1 ,2 ]
Hagenbuch, N. [3 ]
Niesse, O. [1 ,2 ]
Christmann, M. [1 ,2 ]
Knirsch, W. [1 ,2 ]
Kretschmar, O. [1 ,2 ]
机构
[1] Univ Childrens Hosp Zurich, Dept Surg, Pediat Heart Ctr, Pediat Cardiol, Zurich, Switzerland
[2] Childrens Res Ctr, Zurich, Switzerland
[3] Univ Zurich, Epidemiol Biostat & Prevent Inst, Zurich, Switzerland
关键词
DOSE IONIZING-RADIATION; CARDIAC-CATHETERIZATION; HEART-DISEASE; INTERVENTIONAL CLOSURE; X-RAY; EXPOSURE; OCCLUDER; INFANTS;
D O I
10.1155/2019/6598637
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. The aim of this study was to compare feasibility, effectiveness, safety, and outcome of atrial septal defect (ASD) device closure in children with and without fluoroscopy guidance. Methods and Results. Children undergoing transcatheter ASD closure between 2002 and 2016 were included into this single center, retrospective study. Patients were analysed in two groups [1: intraprocedural fluoroscopy +/- transoesophageal echocardiography (TOE) guidance; 2: TOE guidance alone]. Three-hundred-ninety-seven children were included, 238 (97 male) in group 1 and 159 (56 male) in group 2. Two-hundred-twenty-nine of 238 (96%) patients underwent successful fluoroscopy guided ASD closures versus 154/159 (97%) successful procedures with TOE guidance alone. Median weight (IQR) at intervention was 20kg (16.0-35.0) in group 1 versus 19.3kg (16.0-31.2) in group 2. Mean (SD) preinterventional ASD diameter was 12.4mm (4.4) in group 1 versus 12.2mm (3.9) in group 2. There was no significant difference in number of defects or characteristics of ASD rims. Median procedure time was shorter in group 2 [60min (47-86) versus 34min (28-44)]. Device-size-to-defect-ratio was similar in both groups [group 1: 1.07 versus group 2: 1.09]. There were less technical intraprocedural events in group 2 [10 (6.3%) versus 47 (20%)]. Intraprocedural complications were less frequent in group 2 [1 (0.6%) versus 8 (3.3%)]. Conclusion. Transcatheter ASD device closure with TOE guidance alone (i.e., without fluoroscopy) is as effective and safe as ASD closure with fluoroscopy guidance. As fluoroscopy remains an important adjunct to transoesophageal echocardiography, especially in complex defects and complications, procedures are always performed in a fully equipped cardiac catheterization laboratory.
引用
收藏
页数:9
相关论文
共 35 条
[1]  
AGA Medical Corporation, 2016, AMPL SEPT OCC DEL SY
[2]   Subclinical Carotid Atherosclerosis and Early Vascular Aging From Long-Term Low-Dose Ionizing Radiation Exposure A Genetic, Telomere, and Vascular Ultrasound Study in Cardiac Catheterization Laboratory Staff [J].
Andreassi, Maria Grazia ;
Piccaluga, Emanuela ;
Gargani, Luna ;
Sabatino, Laura ;
Borghini, Andrea ;
Faita, Francesco ;
Bruno, Rosa Maria ;
Padovani, Renato ;
Guagliumi, Giulio ;
Picano, Eugenio .
JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (04) :616-627
[3]   Radiation use in the pediatric cath. Lab. How are we doing? [J].
Balter, Stephen .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (02) :302-302
[4]   ESC Guidelines for the management of grown-up congenital heart disease (new version 2010) [J].
Baumgartner, Helmut ;
Bonhoeffer, Philipp ;
De Groot, Natasja M. S. ;
de Haan, Fokko ;
Deanfield, John Erik ;
Galie, Nazzareno ;
Gatzoulis, Michael A. ;
Gohlke-Baerwolf, Christa ;
Kaemmerer, Harald ;
Kilner, Philip ;
Meijboom, Folkert ;
Mulder, Barbara J. M. ;
Oechslin, Erwin ;
Oliver, Jose M. ;
Serraf, Alain ;
Szatmari, Andras ;
Thaulow, Erik ;
Vouhe, Pascal R. ;
Walma, Edmond .
EUROPEAN HEART JOURNAL, 2010, 31 (23) :2915-2957
[5]   FOLLOW-UP OF CHILDREN EXPOSED TO IONISING RADIATION FROM CARDIAC CATHETERISATION: THE COCCINELLE STUDY [J].
Baysson, H. ;
Nkoumazok, B. ;
Barnaoui, S. ;
Rehel, J. L. ;
Girodon, B. ;
Milani, G. ;
Boudjemline, Y. ;
Bonnet, D. ;
Laurier, D. ;
Bernier, M. O. .
RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) :13-16
[6]  
Bonow RO, 2008, J AM COLL CARDIOL, V52, pE1, DOI [10.1016/j.jacc.2008.05.007, 10.1016/j.hrthm.2008.04.014, 10.1016/j.jacc.2008.02.032]
[7]   Transcatheter atrial septal defect closure: Modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer septal occluder [J].
Carlson, KM ;
Justino, H ;
O'Brien, RE ;
Dimas, VV ;
Leonard, GT ;
Pignatelli, RH ;
Mullins, CE ;
Smith, EO ;
Grifka, RG .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (03) :390-396
[8]   A novel tool for user-friendly estimation of natural, diagnostic and professional radiation risk: Radio-Risk software [J].
Carpeggiani, Clara ;
Paterni, Marco ;
Caramella, Davide ;
Vano, Eliseo ;
Semelka, Richard C. ;
Picano, Eugenio .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) :3563-3567
[9]   Cumulative Medical Radiation Exposure Throughout Staged Palliation of Single Ventricle Congenital Heart Disease [J].
Downing, Tacy E. ;
McDonnell, Alicia ;
Zhu, Xiaowei ;
Dori, Yoav ;
Gillespie, Matthew J. ;
Rome, Jonathan J. ;
Glatz, Andrew C. .
PEDIATRIC CARDIOLOGY, 2015, 36 (01) :190-195
[10]  
Du Zhong-Dong, 2002, J Interv Cardiol, V15, P287, DOI 10.1111/j.1540-8183.2002.tb01105.x