The Role of Light Sensitivity and Intrinsic Circadian Period in Predicting Individual Circadian Timing

被引:28
|
作者
Stone, Julia E. [1 ]
McGlashan, Elise M. [1 ]
Quin, Nina [1 ]
Skinner, Kayan [1 ]
Stephenson, Jessica J. [1 ]
Cain, Sean W. [1 ]
Phillips, Andrew J. K. [1 ]
机构
[1] Monash Univ, Fac Med Nursing & Hlth Sci, Sch Psychol Sci, Turner Inst Brain & Mental Hlth, Ground Floor,264 Ferntree Gully Rd, Clayton, Vic 3800, Australia
关键词
circadian phase; mathematical model; light sensitivity; intrinsic period; human; oscillator; parameter estimation; individual differences; ILLUMINATION PUPIL RESPONSE; MELATONIN SUPPRESSION; SLEEP; PHASE; MODEL; ADAPTATION; DIFFERENCE; EXPOSURE; RHYTHMS; PEOPLE;
D O I
10.1177/0748730420962598
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
There is large interindividual variability in circadian timing, which is underestimated by mathematical models of the circadian clock. Interindividual differences in timing have traditionally been modeled by changing the intrinsic circadian period, but recent findings reveal an additional potential source of variability: large interindividual differences in light sensitivity. Using an established model of the human circadian clock with real-world light recordings, we investigated whether changes in light sensitivity parameters or intrinsic circadian period could capture variability in circadian timing between and within individuals. Healthy participants (n= 12, aged 18-26 years) underwent continuous light monitoring for 3 weeks (Actiwatch Spectrum). Salivary dim-light melatonin onset (DLMO) was measured each week. Using the recorded light patterns, a sensitivity analysis for predicted DLMO times was performed, varying 3 model parameters within physiological ranges: (1) a parameter determining the steepness of the dose-response curve to light (p), (2) a parameter determining the shape of the phase-response curve to light (K), and (3) the intrinsic circadian period (tau). These parameters were then fitted to obtain optimal predictions of the three DLMO times for each individual. The sensitivity analysis showed that the range of variation in the average predicted DLMO times across participants was 0.65 h forp, 4.28 h forK, and 3.26 h fortau. The default model predicted the DLMO times with a mean absolute error of 1.02 h, whereas fitting all 3 parameters reduced the mean absolute error to 0.28 h. Fitting the parameters independently, we found mean absolute errors of 0.83 h forp, 0.53 h forK, and 0.42 h fortau. FittingpandKtogether reduced the mean absolute error to 0.44 h. Light sensitivity parameters captured similar variability in phase compared with intrinsic circadian period, indicating they are viable targets for individualizing circadian phase predictions. Future prospective work is needed that uses measures of light sensitivity to validate this approach.
引用
收藏
页码:628 / 640
页数:13
相关论文
共 50 条
  • [1] Plasticity of the Intrinsic Period of the Human Circadian Timing System
    Scheer, Frank A. J. L.
    Wright, Kenneth P., Jr.
    Kronauer, Richard E.
    Czeisler, Charles A.
    PLOS ONE, 2007, 2 (08):
  • [2] Coupling the Circadian Clock to Homeostasis: The Role of Period in Timing Physiology
    Kim, Pureum
    Oster, Henrik
    Lehnert, Hendrik
    Schmid, Sebastian M.
    Salamat, Nicole
    Barclay, Johanna L.
    Maronde, Erik
    Inder, Warrick
    Rawashdeh, Oliver
    ENDOCRINE REVIEWS, 2019, 40 (01) : 66 - 95
  • [3] Mathematical Analysis of Light-sensitivity Related Challenges in Assessment of the Intrinsic Period of the Human Circadian Pacemaker
    Usmani, Imran M.
    Dijk, Derk-Jan
    Skeldon, Anne C.
    JOURNAL OF BIOLOGICAL RHYTHMS, 2024, 39 (02) : 166 - 182
  • [4] Is there an intrinsic period of the circadian clock? Response
    Czeisler, CA
    Dijk, DJ
    Kronauer, RE
    Brown, EN
    Duffy, JF
    Allan, JS
    Shanahan, TL
    Rimmer, DW
    Ronda, JM
    Mitchell, RF
    Silva, EJ
    Emens, JS
    SCIENCE, 2000, 288 (5469) : 1174 - 1175
  • [5] Circadian photoentrainment varies by season and depressed state: associations between light sensitivity and sleep and circadian timing
    Wescott, Delainey L.
    Hasler, Brant P.
    Franzen, Peter L.
    Taylor, Maddison L.
    Klevens, Alison M.
    Gamlin, Paul
    Siegle, Greg J.
    Roecklein, Kathryn A.
    SLEEP, 2024, 47 (06)
  • [6] Individual differences in light sensitivity affect sleep and circadian rhythms
    Chellappa, Sarah L.
    SLEEP, 2021, 44 (02)
  • [7] The Influence of Circadian Timing on Olfactory Sensitivity
    Herz, Rachel S.
    Van Reen, Eliza
    Barker, David H.
    Hilditch, Cassie J.
    Bartz, Ashten L.
    Carskadon, Mary A.
    CHEMICAL SENSES, 2018, 43 (01) : 45 - 51
  • [8] Genetic polymorphism in clock predicts timing of circadian light sensitivity in humans
    Zeitzer, J.
    Friedman, L.
    Zhdanova, P.
    Lin, L.
    Kushida, C.
    Yesavage, J. A.
    SLEEP, 2008, 31 : A365 - A365
  • [9] Desynchronizing the sleep­­–wake cycle from circadian timing to assess their separate contributions to physiology and behaviour and to estimate intrinsic circadian period
    Wei Wang
    Robin K. Yuan
    Jude F. Mitchell
    Kirsi-Marja Zitting
    Melissa A. St. Hilaire
    James K. Wyatt
    Frank A. J. L. Scheer
    Kenneth P. Wright
    Emery N. Brown
    Joseph M. Ronda
    Elizabeth B. Klerman
    Jeanne F. Duffy
    Derk-Jan Dijk
    Charles A. Czeisler
    Nature Protocols, 2023, 18 : 579 - 603
  • [10] Desynchronizing the sleep wake cycle from circadian timing to assess their separate contributions to physiology and behaviour and to estimate intrinsic circadian period
    Wang, Wei
    Yuan, Robin K.
    Mitchell, Jude F.
    Zitting, Kirsi-Marja
    St Hilaire, Melissa A.
    Wyatt, James K.
    Scheer, Frank A. J. L.
    Wright, Kenneth P., Jr.
    Brown, Emery N.
    Ronda, Joseph M.
    Klerman, Elizabeth B.
    Duffy, Jeanne F.
    Dijk, Derk-Jan
    Czeisler, Charles A.
    NATURE PROTOCOLS, 2023, 18 (02) : 579 - 603