Shear wave elastography of the supraspinatus muscle and tendon: Repeatability and preliminary findings

被引:45
作者
Baumer, Timothy G. [1 ]
Davis, Leah [2 ]
Dischler, Jack [1 ]
Siegal, Daniel S. [2 ]
van Holsbeeck, Marnix [2 ]
Moutzouros, Vasilios [3 ]
Bey, Michael J. [1 ]
机构
[1] Henry Ford Hlth Syst, Ctr Bone & Joint, Dept Orthopaed Surg, Detroit, MI USA
[2] Henry Ford Hlth Syst, Dept Radiol, Detroit, MI USA
[3] Henry Ford Hlth Syst, Dept Orthopaed Surg, Sports Med Div, Detroit, MI USA
关键词
Muscle; Tendon; Rotator cuff; Shear wave elastography; ROTATOR CUFF MUSCLE; IN-VIVO; QUANTITATIVE ASSESSMENT; NONINVASIVE ASSESSMENT; ELASTICITY; STIFFNESS; LIVER; FEASIBILITY; SPEED; RELIABILITY;
D O I
10.1016/j.jbiomech.2017.01.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Shear wave elastography (SWE) is a promising tool for estimating musculoskeletal tissue properties, but few studies have rigorously assessed its repeatability and sources of error. The objectives of this study were to assess: (1) the extent to which probe positioning error and human user error influence measurement accuracy, (2) intra-user, inter-user, and day-to-day repeatability, and (3) the extent to which active and passive conditions affect shear wave speed (SWS) repeatability. Probe positioning and human usage errors were assessed by acquiring SWE images from custom ultrasound phantoms. Intra-and inter user repeatability were assessed by two users acquiring five trials of supraspinatus muscle and tendon SWE images from ten human subjects. To assess day-to-day repeatability, five of the subjects were tested a second time, approximately 24 h later. Imaging of the phantoms indicated high inter-user repeatability, with intraclass correlation coefficient (ICC) values of 0.68-0.85, and RMS errors of no more than 4.1%. SWE imaging of the supraspinatus muscle and tendon had high repeatability, with intra-and inter-user ICC values of greater than 0.87 and 0.73, respectively. Day-to-day repeatability demonstrated ICC values greater than 0.33 for passive muscle, 0.48 for passive tendon, 0.65 for active muscle, and 0.94 for active tendon. This study indicates the technique has good to very good intra-and inter-user repeatability, and day-to-day repeatability is appreciably higher when SWE images are acquired under a low level of muscle activation. The findings from this study establish the feasibility and repeatability of SWE for acquiring data longitudinally in human subjects. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:201 / 204
页数:4
相关论文
共 30 条
[1]  
Altman D. G., 1990, Practical Statistics for medical research, DOI DOI 10.1201/9780429258589
[2]   Shear-Wave Elastography Assessments of Quadriceps Stiffness Changes prior to, during and after Prolonged Exercise: A Longitudinal Study during an Extreme Mountain Ultra-Marathon [J].
Andonian, Pierre ;
Viallon, Magalie ;
Le Goff, Caroline ;
de Bourguignon, Charles ;
Tourel, Charline ;
Morel, Jerome ;
Giardini, Guido ;
Gergele, Laurent ;
Millet, Gregoire P. ;
Croisille, Pierre .
PLOS ONE, 2016, 11 (08)
[3]  
ASTM, 1996, STAND PRACT US TERMS
[4]   Measurement of in vivo tendon function [J].
Bey, Michael J. ;
Derwin, Kathleen A. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (02) :149-157
[5]   AN EASILY MADE, LOW-COST, TISSUE-LIKE ULTRASOUND PHANTOM MATERIAL [J].
BUDE, RO ;
ADLER, RS .
JOURNAL OF CLINICAL ULTRASOUND, 1995, 23 (04) :271-273
[6]  
Chino K., 2015, CLIN PHYSL FUNCT IMA
[7]   CONTINUOUS SHEAR WAVE ELASTOGRAPHY: A NEW METHOD TO MEASURE VISCOELASTIC PROPERTIES OF TENDONS IN VIVO [J].
Cortes, Daniel H. ;
Suydam, Stephen M. ;
Silbernagel, Karin Graevare ;
Buchanan, Thomas S. ;
Elliott, Dawn M. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (06) :1518-1529
[8]   Spatial variations in Achilles tendon shear wave speed [J].
DeWall, Ryan J. ;
Slane, Laura C. ;
Lee, Kenneth S. ;
Thelen, Darryl G. .
JOURNAL OF BIOMECHANICS, 2014, 47 (11) :2685-2692
[9]   Superficial ultrasound shear wave speed measurements in soft and hard elasticity phantoms: repeatability and reproducibility using two ultrasound systems [J].
Dillman, Jonathan R. ;
Chen, Shigao ;
Davenport, Matthew S. ;
Zhao, Heng ;
Urban, Matthew W. ;
Song, Pengfei ;
Watcharotone, Kuanwong ;
Carson, Paul L. .
PEDIATRIC RADIOLOGY, 2015, 45 (03) :376-385
[10]   RELIABLE PROTOCOL FOR SHEAR WAVE ELASTOGRAPHY OF LOWER LIMB MUSCLES AT REST AND DURING PASSIVE STRETCHING [J].
Dubois, Guillaume ;
Kheireddine, Walid ;
Vergari, Claudio ;
Bonneau, Dominique ;
Thoreux, Patricia ;
Rouch, Philippe ;
Tanter, Mickael ;
Gennisson, Jean-Luc ;