Noninvasive patient tracker mask for spinal 3D navigation: does the required large-volume 3D scan involve a considerably increased radiation exposure?

被引:5
作者
Klingler, Jan-Helge [1 ]
Hubbe, Ulrich [1 ]
Scholz, Christoph [1 ]
Volz, Florian [1 ]
Hohenhaus, Marc [1 ]
Vasilikos, Ioannis [1 ]
Masalha, Waseem [1 ]
Watzlawick, Ralf [1 ]
Naseri, Yashar [1 ,2 ]
机构
[1] Univ Freiburg, Fac Med, Med Ctr, Dept Neurosurg, Freiburg, Germany
[2] Cantonal Hosp St Gallen, Dept Neurosurg, St Gallen, Switzerland
关键词
digital volume tomography; fluoroscopy; minimally invasive; noninvasive; navigation; radiation exposure; surgical technique; C-ARM; FLUOROSCOPY;
D O I
10.3171/2020.5.SPINE20530
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Intraoperative 3D imaging and navigation is increasingly used for minimally invasive spine surgery. A novel, noninvasive patient tracker that is adhered as a mask on the skin for 3D navigation necessitates a larger intraoperative 3D image set for appropriate referencing. This enlarged 3D image data set can be acquired by a state-of-the-art 3D C-arm device that is equipped with a large flat-panel detector. However, the presumably associated higher radiation exposure to the patient has essentially not yet been investigated and is therefore the objective of this study. METHODS Patients were retrospectively included if a thoracolumbar 3D scan was performed intraoperatively between 2016 and 2019 using a 3D C-arm with a large 30 x 30-cm flat-panel detector (3D scan volume 4096 cm(3)) or a 3D C- arm with a smaller 20 x 20-cm flat-panel detector (3D scan volume 2097 cm(3)), and the dose area product was available for the 3D scan. Additionally, the fluoroscopy time and the number of fluoroscopic images per 3D scan, as well as the BMI of the patients, were recorded. RESULTS The authors compared 62 intraoperative thoracolumbar 3D scans using the 3D C- arm with a large flat-panel detector and 12 3D scans using the 3D C-arm with a small flat-panel detector. Overall, the 3D C-arm with a large flatpanel detector required more fluoroscopic images per scan (mean 389.0 +/- 8.4 vs 117.0 +/- 4.6, p < 0.0001), leading to a significantly higher dose area product (mean 1028.6 +/- 767.9 vs 457.1 +/- 118.9 cGy x cm(2), p = 0.0044). CONCLUSIONS The novel, noninvasive patient tracker mask facilitates intraoperative 3D navigation while eliminating the need for an additional skin incision with detachment of the autochthonous muscles. However, the use of this patient tracker mask requires a larger intraoperative 3D image data set for accurate registration, resulting in a 2.25 times higher radiation exposure to the patient. The use of the patient tracker mask should thus be based on an individual decision, especially taking into considering the radiation exposure and extent of instrumentation.
引用
收藏
页码:838 / 844
页数:7
相关论文
共 16 条
[1]   Digital volume tomography. Dedicated scanner and cone beam CT with C-arm systems [J].
Fiebich, M. ;
Weber, D. .
RADIOLOGE, 2018, 58 (03) :194-201
[2]   Cervical spine imaging using standard C-arm fluoroscopy [J].
Giordano, Brian D. ;
Baumhauer, Judith F. ;
Morgan, Thomas L. ;
Rechtine, Glenn R. .
SPINE, 2008, 33 (18) :1970-1976
[3]   Radiation dose from 3D rotational X-ray imaging: organ and effective dose with conversion factors [J].
Kim, Sangroh ;
Sopko, David ;
Toncheva, Greta ;
Enterline, David ;
Keijzers, Bruno ;
Yoshizumi, Terry T. .
RADIATION PROTECTION DOSIMETRY, 2012, 150 (01) :50-54
[4]   Comparative Study of C-arms for Intraoperative 3-dimensional Imaging and Navigation in Minimally Invasive Spine Surgery Part I Applicability and Image Quality [J].
Klingler, Jan-Helge ;
Sircar, Ronen ;
Scheiwe, Christian ;
Kogias, Evangelos ;
Volz, Florian ;
Krueger, Marie T. ;
Hubbe, Ulrich .
CLINICAL SPINE SURGERY, 2017, 30 (06) :276-284
[5]   Comparative Study of C-Arms for Intraoperative 3-dimensional Imaging and Navigation in Minimally Invasive Spine Surgery Part II Radiation Exposure [J].
Klingler, Jan-Helge ;
Sircar, Ronen ;
Scheiwe, Christian ;
Kogias, Evangelos ;
Krueger, Marie T. ;
Scholz, Christoph ;
Hubbe, Ulrich .
CLINICAL SPINE SURGERY, 2017, 30 (06) :E669-E676
[6]   Image quality and effective dose of a robotic flat panel 3D C-arm vs computed tomography [J].
Kraus, Michael ;
Fischer, Eric ;
Gebhard, Florian ;
Richter, Peter H. .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2016, 12 (04) :743-750
[7]  
Malham GM, 2018, J NEUROSURG-SPINE, V28, P154
[8]  
Malham Gregory M, 2019, J Spine Surg, V5, P155, DOI 10.21037/jss.2019.02.04
[9]  
Naseri Y, BMC MED IMAGING
[10]   Pedicle screw placement accuracy using ultra-low radiation imaging with image enhancement versus conventional fluoroscopy in minimally invasive transforaminal lumbar interbody fusion: an internally randomized controlled trial [J].
Nayar, Gautam ;
Blizzard, Daniel J. ;
Wang, Timothy Y. ;
Cook, Steven ;
Back, Adam G. ;
Vincent, David ;
Karikari, Isaac O. .
JOURNAL OF NEUROSURGERY-SPINE, 2018, 28 (02) :186-193