Finite-element modeling of the hemodynamics of stented aneurysms

被引:83
作者
Stuhne, GR
Steinman, DA
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5C1, Canada
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2004年 / 126卷 / 03期
关键词
D O I
10.1115/1.1762900
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Background. Computational fluid dynamics (CFD) simulations are used to analyze the wall shear stress distribution and flow streamlines near the throat of a stented basilar side-wall aneurysm. Previous studies of stented aneurysm flows used low mesh resolution, did not include mesh convergence analyses, and depended upon conformal meshing techniques that apply only to very artificial stent geometries. Method of Approach. We utilize general-purpose computer assisted design and unstructured mesh generation tools that apply in principle to stents and vasculature of arbitrary complexity. A mesh convergence analysis for stented steady flow is performed, varying node spacing near the stent. Physiologically realistic pulsatile simulations are then performed using the converged mesh. Results. Artifact-free resolution of the wall shear stress field on stent wires requires a node spacing of approximately 113 wire radius. Large-scale flow features tied to the velocity field are, however, captured tit coarser resolution (nodes spaced by about one wire radius or more). Conclusions. Results are consistent with previous work, but our methods yield more detailed insights into the complex flow dynamics. However routine applications of CFD to anatomically realistic cases still depend upon further development of dedicated algorithms, most crucially to handle geometry definition and mesh generation for complicated stent deployments.
引用
收藏
页码:382 / 387
页数:6
相关论文
共 13 条
[1]   Modeling of flow in a straight stented and nonstented side wall aneurysm model [J].
Aenis, M ;
Stancampiano, AP ;
Wakhloo, AK ;
Lieber, BB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (02) :206-212
[2]   Steady flow separation patterns in a 45 degree junction [J].
Ethier, CR ;
Prakash, S ;
Steinman, DA ;
Leask, RL ;
Couch, GG ;
Ojha, M .
JOURNAL OF FLUID MECHANICS, 2000, 411 :1-38
[3]  
ETHIER CR, 1999, ADV COMP BIOENGN, P131
[4]   Three-dimensional pulsatile flow simulation before and after endovascular coil embolization of a terminal cerebral aneurysm [J].
Groden, C ;
Laudan, J ;
Gatchell, S ;
Zeumer, H .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2001, 21 (12) :1464-1471
[5]  
Imbesi SG, 2001, AM J NEURORADIOL, V22, P721
[6]   Three-dimensional computational fluid dynamics modeling of alterations in coronary wall shear stress produced by stent implantation [J].
LaDisa, JF ;
Guler, I ;
Olson, LE ;
Hettrick, DA ;
Kersten, JR ;
Warltier, DC ;
Pagel, PS .
ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (08) :972-980
[7]   Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity [J].
Lieber, BB ;
Stancampiano, AP ;
Wakhloo, AK .
ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (03) :460-469
[8]  
Lieber BB, 2002, NEUROL RES, V24, pS33
[9]   Rapid prototyping applications in medicine. Part 1: NURBS-based volume modelling [J].
Ma, D ;
Lin, F ;
Chua, CK .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2001, 18 (02) :103-117
[10]  
Maday Y., 1990, Journal of Scientific Computing, V5, P263, DOI 10.1007/BF01063118