A novel sensor array for field based ocular ultraviolet radiation measurements

被引:5
|
作者
Fleming, D. P. [1 ]
Walsh, J. E.
Moore, L. A.
Bergmanson, J. P.
McMahon, D.
机构
[1] Dublin Inst Technol, Sch Phys, Focas Inst, Dublin, Ireland
[2] Univ Houston, Coll Optometry, Texas Eye Res & Technol Ctr, Houston, TX USA
关键词
D O I
10.1093/rpd/nci346
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The intensification of terrestrial solar ultraviolet radiation (UVR) due to the diminution of the ozone layer has promoted a variety of research into establishing the impact of this elevated potential dose of UVR on biological tissues. Certain anterior ocular tissues have been found to be susceptible to damage by incident UVR and potentially blinding diseases such as pterygium are thought to be a direct result of absorbed UVR at the nasal limbus. There is a need for more accurate quantification and localisation of incident UVR at the anterior ocular surface. A novel solar blind photodiode sensor array system has been designed, constructed and tested for this purpose. Initial measurements to quantify the irradiance across the anterior ocular surface within the latitudes known as the 'pterygium belt' provide us with a set of core data for different head orientations and tilt angles and indicate the accuracy and stability of the system.
引用
收藏
页码:265 / 274
页数:10
相关论文
共 50 条
  • [31] Small field measurements with a novel silicon position sensitive diode array
    Manolopoulos, S.
    Wojnecki, C.
    Hugtenburg, R.
    Sidek, M. A. Jaafar
    Chalmers, G.
    Heyes, G.
    Green, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (03): : 485 - 495
  • [32] THE OCULAR DOSE OF ULTRAVIOLET-RADIATION TO OUTDOOR WORKERS
    ROSENTHAL, FS
    PHOON, C
    BAKALIAN, AE
    TAYLOR, HR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1988, 29 (04) : 649 - 656
  • [33] THE EFFECT OF SUNGLASSES ON OCULAR EXPOSURE TO ULTRAVIOLET-RADIATION
    ROSENTHAL, FS
    BAKALIAN, AE
    LOU, C
    TAYLOR, HR
    AMERICAN JOURNAL OF PUBLIC HEALTH, 1988, 78 (01) : 72 - 74
  • [34] AN INEXPENSIVE SENSOR FOR ULTRAVIOLET-A AND ULTRAVIOLET-B RADIATION
    HOWIE, JAB
    ROWLES, GK
    HAWKINS, P
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (11) : 1070 - 1073
  • [35] AN ABBREVIATED ASSESSMENT OF OCULAR EXPOSURE TO ULTRAVIOLET-RADIATION
    TAYLOR, HR
    MUNOZ, B
    ROSENTHAL, FS
    WEST, S
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1992, 20 (03): : 219 - 223
  • [36] Method for Measurements of Terrestrial Ultraviolet Radiation on Inclined Surfaces in Personal Dosimetry Field Studies
    Corradi, Elena
    Baczynska, Katarzyna A.
    Morelii, Marco
    Giulietti, Danilo
    Khazova, Marina
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2019, 95 (06) : 1454 - 1460
  • [37] Sensor Array for PV Shading Measurements
    Barreiro, C. D.
    Bross, A.
    Schmalzel, J. L.
    Jansson, P. M.
    2011 IEEE SENSORS, 2011, : 1889 - 1892
  • [38] Wearable sensor array for biopotential measurements
    Rymarczyk, Tomasz
    Stanikowski, Andrzej
    Nita, Pawel
    2019 APPLICATIONS OF ELECTROMAGNETICS IN MODERN ENGINEERING AND MEDICINE (PTZE), 2019, : 184 - 187
  • [39] A Plant-Based Sensor for UV-A Radiation Measurements
    Trigona, Carlo
    Napoli, Giuseppe
    Pasquale, Stefania
    Puglisi, Ivana
    Baglieri, Andrea
    Gueli, Anna Maria
    2021 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2021), 2021,
  • [40] In vivo quantification of the ultraviolet Radiation field AT the human eye USING Novel instrumentation
    Bergmanson, JG
    Gaume, A
    Walsh, J
    Moore, L
    Sheriff, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U22 - U22