Digital replacement of the distorted dentition acquired by cone beam computed tomography (CBCT): a pilot study

被引:14
作者
Nairn, N. J. [1 ]
Ayoub, A. F. [1 ]
Barbenel, J. [1 ]
Moos, K. [1 ]
Naudi, K. [1 ]
Ju, X. [1 ]
Khambay, B. S. [1 ]
机构
[1] Univ Glasgow, Glasgow Dent Hosp & Sch, Glasgow, Lanark, Scotland
关键词
orthognathic surgery; superimposition; models; cone beam computed tomography; SCAN PROCEDURE; ORTHOGNATHIC SURGERY; CT; SIMULATION; ARTIFACTS; IMAGES; FUSION; MODEL;
D O I
10.1016/j.ijom.2013.01.026
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
During cone beam computed tomography (CBCT) scanning, intra-oral metallic objects may produce streak artefacts, which impair the occlusal surface of the teeth. This study aimed to determine the accuracy of replacement of the CBCT dentition with a more accurate dentition and to determine the clinical feasibility of the method. Impressions of the teeth of six cadaveric skulls with unrestored dentitions were taken and acrylic base plates constructed incorporating radiopaque registration markers. Each appliance was fitted to the skull and a CBCT performed. Impressions were taken of the dentition with the devices in situ and dental models were produced. These were CBCT-scanned and the images of the skulls and models imported into computer-aided design/computer-aided manufacturing (CAD/CAM) software and aligned on the registration markers. The occlusal surfaces of each dentition were then replaced with the occlusal image of the corresponding model. The absolute mean distance between the registration markers in the skulls and the dental models was 0.09 +/- 0.02 mm, and for the dentition was 0.24 +/- 0.09 mm. When the method was applied to patients, the distance between markers was 0.12 +/- 0.04 mm for the maxilla and 0.16 +/- 0.02 mm for the mandible. It is possible to replace the inaccurate dentition on a CBCT scan using this method and to create a composite skull which is clinically acceptable.
引用
收藏
页码:1488 / 1493
页数:6
相关论文
共 50 条
  • [31] Use of cone beam computed tomography to determine the accuracy of panoramic radiological markers: A pilot study
    Kursun, Sebnem
    Hakan, Kurt M.
    Bengi, Oztas
    Nihat, Akbulut
    JOURNAL OF DENTAL SCIENCES, 2015, 10 (02) : 167 - 171
  • [32] Analysis of Vector Models in Quantification of Artifacts Produced by Standard Prosthetic Inlays in Cone-Beam Computed Tomography (CBCT) - a Preliminary Study
    Rozylo-Kalinowska, Ingrid
    Miechowicz, Slawomir
    Sarna-Bos, Katarzyna
    Borowicz, Janusz
    Kalinowski, Pawel
    POSTEPY HIGIENY I MEDYCYNY DOSWIADCZALNEJ, 2014, 68 : 1343 - 1346
  • [33] Characteristics of patients referred for Cone Beam Computed Tomography (CBCT) of ectopically erupting maxillary canines
    Koye, Vianne
    Grondahl, Hans-Goran
    SWEDISH DENTAL JOURNAL, 2011, 35 (03) : 159 - 168
  • [34] Cone Beam computed tomography (CBCT) applications in image-guided minimally invasive procedures
    Serrano, E.
    Jose, J. Valcarcel
    Paez-Carpio, A.
    Matute-Gonzalez, M.
    Werner, M. F.
    Lopez-Rueda, A.
    RADIOLOGIA, 2025, 67 (01): : 38 - 53
  • [35] Audiological correlates of cone beam computed tomography (CBCT) in cochlear implant recipients
    Rahman, Tayseer Taha Abdel
    Kader, Hesham Abd El Aty Abdel
    Aziz, Tougan Taha Abdel
    HEARING BALANCE AND COMMUNICATION, 2019, 17 (04) : 249 - 256
  • [36] Cone beam computed tomography (CBCT) in periodontal diseases: a Systematic review based on the efficacy model
    Assiri, Hassan
    Dawasaz, Ali Azhar
    Alahmari, Ahmad
    Asiri, Zuhair
    BMC ORAL HEALTH, 2020, 20 (01)
  • [37] The reliability of cone-beam computed tomography (CBCT) - Generated frontal cephalogramsq
    Kim, So-Jin
    Park, Soo-Byung
    Kim, Yong-Il
    Cho, Bong-Hae
    Hwang, Dae-Seok
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2012, 40 (08) : E331 - E336
  • [38] Effect of Craniofacial Morphology on Pharyngeal Airway Volume Measured Using Cone-Beam Computed Tomography (CBCT)-A Retrospective Pilot Study
    Diwakar, Rohan
    Kochhar, Anuraj Singh
    Gupta, Harshita
    Kaur, Harneet
    Sidhu, Maninder Singh
    Skountrianos, Helen
    Singh, Gurkeerat
    Tepedino, Michele
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (09)
  • [39] Cone-Beam Computed Tomography (CBCT) Imaging for the Assessment of Periodontal Disease
    Sousa Melo S.L.
    Rovaris K.
    Javaheri A.M.
    de Rezende Barbosa G.L.
    Current Oral Health Reports, 2020, 7 (4) : 376 - 380
  • [40] Experiences with image quality and radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in pediatric extremity trauma
    Tschauner, Sebastian
    Marterer, Robert
    Nagy, Eszter
    Singer, Georg
    Riccabona, Michael
    Sorantin, Erich
    SKELETAL RADIOLOGY, 2020, 49 (12) : 1939 - 1949