Accuracy, reproducibility, and dimensional stability of additively manufactured surgical templates

被引:81
作者
Chen, Li [1 ,2 ,3 ,4 ,5 ]
Lin, Wei-Shao [6 ]
Polido, Waldemar D. [7 ,8 ]
Eckert, George J. [9 ]
Morton, Dean [6 ]
机构
[1] Peking Univ, Dept Prosthodont, Sch & Hosp Stomatol, Beijing, Peoples R China
[2] Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[3] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
[4] Beijing Key Lab Digital Stomatol, Beijing, Peoples R China
[5] Univ Louisville, Sch Dent, Dept Oral Hlth & Rehabil, Div Prosthodont, Louisville, KY 40292 USA
[6] Indiana Univ, Sch Dent, Dept Prosthodont, 1121 W Michigan St,Off DS 5406, Indianapolis, IN 46202 USA
[7] Indiana Univ, Sch Dent, Dept Oral Surg, Indianapolis, IN 46202 USA
[8] Indiana Univ, Sch Dent, Hosp Dent, Indianapolis, IN 46202 USA
[9] Indiana Univ Sch Med, Dept Biostat, Indianapolis, IN 46202 USA
关键词
COMPUTER-GUIDED SURGERY; IMPLANT PLACEMENT; STEREOLITHOGRAPHIC GUIDES; CAD-CAM; TOMOGRAPHY; TOLERANCE;
D O I
10.1016/j.prosdent.2019.02.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Additively manufactured surgical templates are commonly used for computer-guided implant placement. However, their accuracy, reproducibility, and dimensional stability have not been thoroughly investigated with the different 3D printers and materials used for their fabrication. Purpose. The purpose of this in vitro study was to evaluate the accuracy, reproducibility, and dimensional stability of additively manufactured surgical templates fabricated by using different 3D printers. Material and methods. Thirty surgical templates were designed and additively manufactured from 3 different 3D printers as follows: group SLA (n=10) was fabricated by using a desktop stereolithography (SLA) 3D printer and photopolymerizing resin; group PolyJet (n=10) was fabricated by using a PolyJet 3D printer and photopolymerizing resins; and group DMP (n=10) was fabricated by using a direct metal printing (DMP) system and Co-Cr metal alloy. All surgical templates were scanned by using a laser scanner within 36 hours of production and digitalized again 1 month later. All scanned files were compared with the corresponding designed files in a surface matching software program. The mean deviation root mean square (RMS, measured in mm, representing accuracy), percentage of measurement data points within 1 standard deviation of mean RMS (in %, representing reproducibility), and dimensional changes were determined and compared. Results. At the postproduction stage, group PolyJet was most accurate with the lowest RMS value of 0.10 +/- 0.02 mm and highest reproducibility with 93.07 +/- 1.54% of measurement data points within 1 standard deviation of mean RMS. After 1-month storage, group PolyJet((1month)) remained the most accurate with the lowest RMS value of 0.14 +/- 0.03 mm and the highest reproducibility value of 92.46 +/- 1.50%. For dimensional stability, group SLA versus group SLA((1month)) comparison showed a significant decrease in accuracy (RMS values of 0.20 +/- 0.08 mm versus 0.25 +/- 0.08 mm, P<.001) and reproducibility (88.16 +/- 3.66% versus 86.10 +/- 4.16%, P=.012). Group PolyJet versus group PolyJet((1month) )comparison only showed significant changes in accuracy (RMS values of 0.10 +/- 0.02 mm versus 0.14 +/- 0.03 mm, P=.011). Group DMP versus group DMP(1month) comparison showed no significant changes in accuracy (RMS values of 0.19 +/- 0.03 mm versus 0.20 +/- 0.04 mm, P=.981) or reproducibility (89.77 +/- 1.61% versus 89.74 +/- 2.24%, P=1.000). Conclusion. Printed resin surgical templates produced by using the PolyJet 3D printer showed higher accuracy and reproducibility than those produced by using the desktop SLA 3D printer and printed Co-Cr surgical templates at both the postproduction stage and after 1-month storage. The level of accuracy and reproducibility in printed Co-Cr surgical templates was not affected by 1-month storage.
引用
收藏
页码:309 / 314
页数:6
相关论文
共 29 条
[1]   Removable partial denture alloys processed by laser-sintering technique [J].
Alageel, Omar ;
Abdallah, Mohamed-Nur ;
Alsheghri, Ammar ;
Song, Jun ;
Caron, Eric ;
Tamimi, Faleh .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (03) :1174-1185
[2]   Digital approach to planning computer-guided surgery and immediate provisionalization in a partially edentulous patient [J].
Arunyanak, Sirikarn P. ;
Harris, Bryan T. ;
Grant, Gerald T. ;
Morton, Dean ;
Lin, Wei-Shao .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (01) :8-14
[3]   Additive Technology: Update on Current Materials and Applications in Dentistry [J].
Barazanchi, Abdullah ;
Li, Kai Chun ;
Al-Amleh, Basil ;
Lyons, Karl ;
Waddell, J. Neil .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (02) :156-163
[4]   Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study [J].
Beretta, Mario ;
Poli, Pier Paolo ;
Maiorana, Carlo .
JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2014, 44 (04) :184-193
[5]   Implant Placement Accuracy Using Dynamic Navigation [J].
Block, Michael S. ;
Emery, Robert W. ;
Lank, Kathryn ;
Ryan, James .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) :92-99
[6]   Stability of Contour Augmentation and Esthetic Outcomes of Implant-Supported Single Crowns in the Esthetic Zone: 3-Year Results of a Prospective Study With Early Implant Placement Postextraction [J].
Buser, Daniel ;
Wittneben, Julia ;
Bornstein, Michael M. ;
Gruetter, Linda ;
Chappuis, Vivianne ;
Belser, Urs C. .
JOURNAL OF PERIODONTOLOGY, 2011, 82 (03) :342-349
[7]   The Influence of the Tolerance between Mechanical Components on the Accuracy of Implants Inserted with a Stereolithographic Surgical Guide: A Retrospective Clinical Study [J].
Cassetta, Michele ;
Di Mambro, Alfonso ;
Di Giorgio, Gianni ;
Stefanelli, Luigi V. ;
Barbato, Ersilia .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (03) :580-588
[8]   Comparison of accuracy and reproducibility of casts made by digital and conventional methods [J].
Cho, Seok-Hwan ;
Schaefer, Oliver ;
Thompson, Geoffrey A. ;
Guentsch, Arndt .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (04) :310-315
[9]   Accuracy evaluation of surgical guides in implant dentistry by non-contact reverse engineering techniques [J].
Giordano, M. ;
Ausiello, P. ;
Martorelli, M. .
DENTAL MATERIALS, 2012, 28 (09) :E178-E185
[10]  
Goodacre BJ, 2016, J PROSTHET DENT, V116, P249, DOI 10.1016/j.prosdent.2016.02.017