Investigation of a vehicle fire caused by manufacturing defect

被引:4
作者
Zhang, Bin [1 ,2 ]
Lu, Zhibao [1 ,2 ]
Liu, Zhengang [1 ,2 ]
Liang, Guofu [1 ,2 ]
Chen, Yingchun [1 ,2 ]
机构
[1] Tianjin Fire Res Inst, Minist Publ Secur, Tianjin 300381, Peoples R China
[2] Tianjin Fire Evidence Identificat Ctr Fire Bur, Tianjin 300381, Peoples R China
关键词
Fire investigation; Vehicle fire; Fracture analysis; Fire scene;
D O I
10.1016/j.engfailanal.2018.04.020
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
An unreported cause of vehicle fire has been identified using a series of scientific approaches including fracture analysis. A fracture was found adjacent to the welding joint of right catalytic converter and exhaust manifold, which was the probable point of origin, of the burned vehicle. Using fracture analysis, it was verified that the fracture initiate due to the welding crack and formed far before the fire. Thus, it was confirmed that the hot air ejected from right catalytic converter via the fracture ignite the pipeline and/or fuel nearby, initiate the vehicle fire.
引用
收藏
页码:28 / 34
页数:7
相关论文
共 4 条
[1]  
DeHaan J.D., 2002, KIRKS FIRE INVESTIGA
[2]  
Fournier E., 2004, HOOD TEMPERATURE MEA
[3]  
Michael J.K., 2013, FLX1001 NFPA FIR AN
[4]  
National Fire Protection Association, 2020, NFPA 921 GUID FIR EX