Diagnostic accuracy of DW MR imaging in the differentiation of chordomas and chondrosarcomas of the skull base: A 3.0-T MRI study of 105 cases

被引:21
|
作者
Welzel, Thomas [1 ]
Meyerhof, Eva [1 ]
Uhl, Matthias [1 ,2 ]
Huang, Kristin [3 ]
von Deimling, Andreas [3 ]
Herfarth, Klaus [1 ,2 ]
Debus, Juergen [1 ,2 ,4 ,5 ]
机构
[1] Heidelberg Univ, Dept Radiooncol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Heidelberg Ion Therapy Ctr HIT, Neuenheimer Feld 450, D-69120 Heidelberg, Germany
[3] Heidelberg Univ, Dept Neuropathol, Neuenheimer Feld 672, D-69120 Heidelberg, Germany
[4] German Canc Res Ctr, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[5] German Canc Consortium DKTK, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
关键词
MR imaging; Sensitivity; Specificity; Apparent diffusion coefficient; Chordomas; Chondrosarcomas; CT;
D O I
10.1016/j.ejrad.2018.05.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the diagnostic accuracy of DW MR imaging with apparent diffusion coefficient (ADC) mapping for the distinction of skull base chordoma from skull base chondrosarcoma. Patients and Methods: From October 2009 to April 2014, 105 consecutive patients (chordomas (n = 70), and chondrosarcomas (n = 35) who were planned to receive proton or heavy-ion beam therapy underwent DW MR imaging on a 3.0 T. MR images were assessed by means of consensus of three experienced radiologists who were blinded to pathologic and clinical information. ADC values (mean, minimum, maximum, and normalized) of the solid tumor component were evaluated. Group means and cut-off points were established to separate skull base chordoma from skull base chondrosarcoma, and statistical significances were calculated by Student's t or MannVVhitney-U tests, and receiver operating characteristic (ROC) curve analyses. The prospective study was approved by the institutional ethics committee. Results: For solid tumor component, there were higher mean, minimum, maximum, and normalized ADC values in chondrosarcomas compared with those in chordomas (all p < 0.001). ROC analysis revealed areas under the curve for mean, minimum, maximum, and normalized ADC values between 0.79 and 0.93. The mean ADC value of the solid tumor components had the best AUC, with a cut-off point of 1585 x 10(- 6) mm (2)/s and sensitivity and specificity of 94.3% and 98.6%, respectively. Conclusion: Skull base Chondrosarcomas generally have higher mean, minimum, maximum, and normalized ADC values than skull base chordomas, with the mean ADC value of the solid tumor component offering the highest accuracy for characterization.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 3 条
  • [1] Brachial plexus MR imaging: accuracy and reproducibility of DTI-derived measurements and fibre tractography at 3.0-T
    Tagliafico, Alberto
    Calabrese, Massimo
    Puntoni, Matteo
    Pace, Daniele
    Baio, Gabriella
    Neumaier, Carlo Emanuele
    Martinoli, Carlo
    EUROPEAN RADIOLOGY, 2011, 21 (08) : 1764 - 1771
  • [2] Brachial plexus MR imaging: accuracy and reproducibility of DTI-derived measurements and fibre tractography at 3.0-T
    Alberto Tagliafico
    Massimo Calabrese
    Matteo Puntoni
    Daniele Pace
    Gabriella Baio
    Carlo Emanuele Neumaier
    Carlo Martinoli
    European Radiology, 2011, 21 : 1764 - 1771
  • [3] Comparison of glucagon-like peptide-1 receptor (GLP-1R) PET/CT, SPECT/CT and 3T MRI for the localisation of occult insulinomas: evaluation of diagnostic accuracy in a prospective crossover imaging study
    Antwi, Kwadwo
    Fani, Melpomeni
    Heye, Tobias
    Nicolas, Guillaume
    Rottenburger, Christof
    Kaul, Felix
    Merkle, Elmar
    Zech, Christoph J.
    Boll, Daniel
    Vogt, Deborah R.
    Gloor, Beat
    Christ, Emanuel
    Wild, Damian
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (13) : 2318 - 2327