Porous Copper-Modified Graphite Pencil Electrode for the Amperometric Detection of 4-Nitrophenol

被引:42
|
作者
Kawde, Abdel-Nasser [1 ,2 ]
Aziz, Md. Abdul [1 ,3 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Chem, Dhahran 31261, Saudi Arabia
[2] Assiut Univ, Fac Sci, Dept Chem, Assiut 71516, Egypt
[3] King Fahd Univ Petr & Minerals, Ctr Res Excellence Nanotechnol, Dhahran 31261, Saudi Arabia
关键词
Porous copper; Graphite pencil electrode; Electrodeposition; 4-Nitophenol; Amperometric sensor; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL DETECTION; SENSITIVE DETERMINATION; FILM ELECTRODE; P-AMINOPHENOL; NITROPHENOL; SENSOR; POLYMERIZATION; NANOPARTICLES; REDUCTION;
D O I
10.1002/elan.201400281
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To overcome the well-known carbon electrodes surface fouling of phenols, we report on a simple and rapid method for the preparation of a disposable porous Cu-modified graphite pencil electrode (Cu-GPE) for sensing 4-nitrophenol (4-NP). The bare- and Cu-modified graphite pencil electrodes were characterized by cyclic voltammetry and SEM. The two electrodes displayed distinct electrocatalytic activities in response to the electro-chemical redox reaction of 4-NP. A difference of three orders of magnitude is obtained on the amperometric detection limits of 1.9 mu M on porous Cu-modified vs. 1.0 mM on bare-graphite pencil electrode at 3s. The Cu-GPEs are fabricated utilizing a simple single method, and at an extremely low cost with high stability, selectivity and sensitivity, offering a promising tool for sensing 4-NP.
引用
收藏
页码:2484 / 2490
页数:7
相关论文
共 50 条
  • [21] Copper-modified gold electrode specific for monosaccharide detection - Use in amperometric determination of phenylmercury based on invertase enzyme inhibition
    Mohammadi, H
    Amine, A
    El Rhazi, M
    Brett, CMA
    TALANTA, 2004, 62 (05) : 951 - 958
  • [22] Pre-Anodized Graphite Pencil Electrode Coated with a Poly(Thionine) Film for Simultaneous Sensing of 3-Nitrophenol and 4-Nitrophenol in Environmental Water Samples
    Sree, Vijaya Gopalan
    Sohn, Jung Inn
    Im, Hyunsik
    SENSORS, 2022, 22 (03)
  • [23] Sensitive Amperometric Detection of Hydroxylamine at Electropolymerized Curcumin Film Coated Pencil Graphite Electrode
    Gunes, Mehmet
    Sap, Ayse
    Karakaya, Serkan
    Yaman, Mehmet
    Dilgin, Yusuf
    CHEMISTRYSELECT, 2023, 8 (18):
  • [24] Nanomolar amperometric sensing of hydrogen peroxide using a graphite pencil electrode modified with palladium nanoparticles
    Md. Abdul Aziz
    Abdel-Nasser Kawde
    Microchimica Acta, 2013, 180 : 837 - 843
  • [25] Amperometric determination of sulfide based on its electrocatalytic oxidation at a pencil graphite electrode modified with quercetin
    Dilgin, Yusuf
    Kizilkaya, Bayram
    Ertek, Bensu
    Erena, Nuri
    Dilgin, Didem Giray
    TALANTA, 2012, 89 : 490 - 495
  • [26] Nanomolar amperometric sensing of hydrogen peroxide using a graphite pencil electrode modified with palladium nanoparticles
    Aziz, Md Abdul
    Kawde, Abdel-Nasser
    MICROCHIMICA ACTA, 2013, 180 (9-10) : 837 - 843
  • [27] pH robust electrochemical detection of 4-nitrophenol on a reduced graphene oxide modified glassy carbon electrode
    Wiench, Piotr
    Grzyb, Bartosz
    Gonzalez, Zoraida
    Menendez, Rosa
    Handke, Bartosz
    Gryglewicz, Grazyna
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 787 : 80 - 87
  • [28] Bismuth Modified Disposable Pencil-Lead Electrode for Simultaneous Determination of 2-Nitrophenol and 4-Nitrophenol by Net Analyte Signal Standard Addition Method
    Asadpour-Zeynali, Karim
    Najafi-Marandi, Parvaneh
    ELECTROANALYSIS, 2011, 23 (09) : 2241 - 2247
  • [29] Pencil Graphite Electrocatalytic Sensors Modified by Pyrene Coated Reduced Graphene Oxide Decorated with Molybdenum Disulfide Nanoroses for Hydrazine and 4-Nitrophenol Detection in Real Water Samples
    Mejri, Alma
    Mandriota, Giacomo
    Hamza, Elfil
    Curri, Maria Lucia
    Ingrosso, Chiara
    Mars, Abdelmoneim
    MOLECULES, 2023, 28 (21):
  • [30] Voltammetric detection of nitrate in water sample based on in situ copper-modified electrode
    Luo, Xue
    Wu, Jian
    Ying, Yibin
    IONICS, 2013, 19 (08) : 1171 - 1177