共 50 条
Porous Copper-Modified Graphite Pencil Electrode for the Amperometric Detection of 4-Nitrophenol
被引:42
|作者:
Kawde, Abdel-Nasser
[1
,2
]
Aziz, Md. Abdul
[1
,3
]
机构:
[1] King Fahd Univ Petr & Minerals, Dept Chem, Dhahran 31261, Saudi Arabia
[2] Assiut Univ, Fac Sci, Dept Chem, Assiut 71516, Egypt
[3] King Fahd Univ Petr & Minerals, Ctr Res Excellence Nanotechnol, Dhahran 31261, Saudi Arabia
关键词:
Porous copper;
Graphite pencil electrode;
Electrodeposition;
4-Nitophenol;
Amperometric sensor;
VOLTAMMETRIC DETERMINATION;
ELECTROCHEMICAL DETECTION;
SENSITIVE DETERMINATION;
FILM ELECTRODE;
P-AMINOPHENOL;
NITROPHENOL;
SENSOR;
POLYMERIZATION;
NANOPARTICLES;
REDUCTION;
D O I:
10.1002/elan.201400281
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
To overcome the well-known carbon electrodes surface fouling of phenols, we report on a simple and rapid method for the preparation of a disposable porous Cu-modified graphite pencil electrode (Cu-GPE) for sensing 4-nitrophenol (4-NP). The bare- and Cu-modified graphite pencil electrodes were characterized by cyclic voltammetry and SEM. The two electrodes displayed distinct electrocatalytic activities in response to the electro-chemical redox reaction of 4-NP. A difference of three orders of magnitude is obtained on the amperometric detection limits of 1.9 mu M on porous Cu-modified vs. 1.0 mM on bare-graphite pencil electrode at 3s. The Cu-GPEs are fabricated utilizing a simple single method, and at an extremely low cost with high stability, selectivity and sensitivity, offering a promising tool for sensing 4-NP.
引用
收藏
页码:2484 / 2490
页数:7
相关论文