Probability method for Cerenkov luminescence tomography based on conformance error minimization

被引:27
作者
Ding, Xintao [1 ,2 ]
Wang, Kun [3 ]
Jie, Biao [2 ]
Luo, Yonglong [2 ]
Hu, Zhenhua [3 ]
Tian, Jie [3 ]
机构
[1] Anhui Normal Univ, Sch Terr Resources & Tourism, Wuhu 241003, Anhui, Peoples R China
[2] Anhui Normal Univ, Sch Math & Comp Sci, Wuhu 241003, Anhui, Peoples R China
[3] Chinese Acad Sci, Inst Automat, Key Lab Mol Imaging, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
RECONSTRUCTION METHOD; OPTICAL-PROPERTIES; CONDITION NUMBERS; LIGHT; PROPAGATION; BOUNDARY; MEDIA; MODEL;
D O I
10.1364/BOE.5.002091
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cerenkov luminescence tomography (CLT) was developed to reconstruct a three-dimensional (3D) distribution of radioactive probes inside a living animal. Reconstruction methods are generally performed within a unique framework by searching for the optimum solution. However, the ill-posed aspect of the inverse problem usually results in the reconstruction being non-robust. In addition, the reconstructed result may not match reality since the difference between the highest and lowest uptakes of the resulting radiotracers may be considerably large, therefore the biological significance is lost. In this paper, based on the minimization of a conformance error, a probability method is proposed that consists of qualitative and quantitative modules. The proposed method first pinpoints the organ that contains the light source. Next, we developed a 0-1 linear optimization subject to a space constraint to model the CLT inverse problem, which was transformed into a forward problem by employing a region growing method to solve the optimization. After running through all of the elements used to grow the sources, a source sequence was obtained. Finally, the probability of each discrete node being the light source inside the organ was reconstructed. One numerical study and two in vivo experiments were conducted to verify the performance of the proposed algorithm, and comparisons were carried out using the hp-finite element method (hp-FEM). The results suggested that our proposed probability method was more robust and reasonable than hp-FEM. (C) 2014 Optical Society of America
引用
收藏
页码:2091 / 2112
页数:22
相关论文
共 53 条
[1]   Parametric Level Set Methods for Inverse Problems [J].
Aghasi, Alireza ;
Kilmer, Misha ;
Miller, Eric L. .
SIAM JOURNAL ON IMAGING SCIENCES, 2011, 4 (02) :618-650
[2]   Fast iterative image reconstruction methods for fully 3D multispectral bioluminescence tomography [J].
Ahn, Sangtae ;
Chaudhari, Abhijit J. ;
Darvas, Felix ;
Bouman, Charles A. ;
Leahy, Richard M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (14) :3921-3942
[3]  
[Anonymous], 2013, PARAMETER ESTIMATION, DOI DOI 10.1016/B978-0-12-385048-5.00010-0
[4]  
[Anonymous], 1977, Solution of illposed problems
[5]   Quantitative Modeling of Cerenkov Light Production Efficiency from Medical Radionuclides [J].
Beattie, Bradley J. ;
Thorek, Daniel L. J. ;
Schmidtlein, Charles R. ;
Pentlow, Keith S. ;
Humm, John L. ;
Hielscher, Andreas H. .
PLOS ONE, 2012, 7 (02)
[6]  
Ben-Israel A., 2003, Generalized inverses: theory and applications
[7]   In vivo 18F-FDG tumour uptake measurements in small animals using Cerenkov radiation [J].
Boschi, Federico ;
Calderan, Laura ;
D'Ambrosio, Daniela ;
Marengo, Mario ;
Fenzi, Alberto ;
Calandrino, Riccardo ;
Sbarbati, Andrea ;
Spinelli, Antonello E. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (01) :120-127
[8]   The generalized condition numbers of bounded linear operators in Banach spaces [J].
Chen, GL ;
Wei, YM ;
Xue, YF .
JOURNAL OF THE AUSTRALIAN MATHEMATICAL SOCIETY, 2004, 76 :281-290
[9]   Cerenkov radiation imaging as a method for quantitative measurements of beta particles in a microfluidic chip [J].
Cho, Jennifer S. ;
Taschereau, Richard ;
Olma, Sebastian ;
Liu, Kan ;
Chen, Yi-Chun ;
Shen, Clifton K-F ;
van Dam, R. Michael ;
Chatziioannou, Arion F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22) :6757-6771
[10]   A finite-element-based reconstruction method for 3D fluorescence tomography [J].
Cong, AX ;
Wang, G .
OPTICS EXPRESS, 2005, 13 (24) :9847-9857