Effect of a novel denoising technique on image quality and diagnostic accuracy in low-dose CT in patients with suspected appendicitis

被引:26
|
作者
Kolb, Manuel [1 ]
Storz, Corinna [1 ]
Kim, Jong Hyo [2 ]
Weiss, Jakob [1 ]
Afat, Saif [1 ]
Nikolaou, Konstantin [1 ]
Bamberg, Fabian [1 ]
Othman, Ahmed E. [1 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Radiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Seoul Natl Univ, Dept Radiol, 101 Daehak Ro, Seoul, South Korea
关键词
Tomography; X-Ray computed; Diagnostic imaging; Appendicitis; COMPUTED-TOMOGRAPHY; ABDOMINAL CT; IMPACT; EPIDEMIOLOGY; RELIABILITY; OUTCOMES; PAIN;
D O I
10.1016/j.ejrad.2019.04.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To determine the effect of a vendor unspecific, DICOM-based denoising technique on image quality and diagnostic performance in low-dose simulated abdominal computed tomography (CT) examinations in patients with suspected appendicitis. Methods and Materials: We included 51 patients who underwent contrast-enhanced abdominal CT with Filtered Back Projection due to suspected appendicitis. Realistic Low-Dose simulation generated low-dose datasets at 25% of the original exposition. QuantaStream Denoising, a novel DICOM-based technique denoised the simulated low-Dose datasets. Original (0100), low-dose (LD25) and denoised (DN25) datasets (n = 153) were evaluated regarding subjective image quality (5-point Likert scale; overall quality/image noise/diagnostic confidence), presence/absence of acute appendicitis, free abdominal air and abscess formation and objective image quality (Signal-to-Noise Ratio (SNR) and noise level) by two independent readers. Results: Subjective image quality was rated highest for O100, followed by DN25 and LD25 with significant differences (p = 0.001). Appendicitis was correctly identified in all datasets (n = 30). Appendicitis specific diagnostic confidence was highest for 0100 (p = 0.001), followed by DN25 and LD25 without significant difference. All complications were correctly identified on 0100 and DN25. On LD25, diagnostic accuracy decreased for abscess formations (sensitivity:0.714; specificity:1.0) and for free abdominal air (sensitivity:0.750; specificity:0.936). Regarding noise levels DN25 showed non-inferiority to 0100. SNRs of 0100 and DN25 showed no significant difference (p = 0.06). Conclusion: Our findings indicate that QuantaStream Denoising allows for maintained diagnostic image quality and diagnostic accuracy of low-dose abdominal CT examinations (25% of original exposition) in patients with suspected appendicitis without the need for raw sinogram data.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 50 条
  • [41] Low-Dose (2-mSv) CT in Adolescents and Young Adults With Suspected Appendicitis: Advantages of Additional Review of Thin Sections Using Multiplanar Sliding-Slab Averaging Technique
    Lee, Yoon Jin
    Kim, Bohyoung
    Ko, Yousun
    Cho, Kyung Eun
    Hong, Seong Sook
    Kim, Dong Hwan
    Song, Hyunjoo
    Lee, Kyoung Ho
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (05) : W485 - W491
  • [42] Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose
    Hein, E
    Rogalla, P
    Klingebiel, R
    Hamm, B
    EUROPEAN RADIOLOGY, 2002, 12 (07) : 1693 - 1696
  • [43] Improving Diagnostic Accuracy in Low-Dose SPECT Myocardial Perfusion Imaging With Convolutional Denoising Networks
    Ramon, Albert Juan
    Yang, Yongyi
    Pretorius, P. Hendrik
    Johnson, Karen L.
    King, Michael A.
    Wernick, Miles N.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (09) : 2893 - 2903
  • [44] Investigation of Low-Dose CT Image Denoising Using Unpaired Deep Learning Methods
    Li, Zeheng
    Zhou, Shiwei
    Huang, Junzhou
    Yu, Lifeng
    Jin, Mingwu
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (02) : 224 - 234
  • [45] Real-World Low-Dose CT Image Denoising by Patch Similarity Purification
    Song, Zeya
    Xue, Liqi
    Xu, Jun
    Zhang, Baoping
    Jin, Chao
    Yang, Jian
    Zou, Changliang
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2025, 34 : 196 - 208
  • [46] Denoising swin transformer and perceptual peak signal-to-noise ratio for low-dose CT image denoising
    Zhang, Boyan
    Zhang, Yingqi
    Wang, Binjie
    He, Xin
    Zhang, Fan
    Zhang, Xinhong
    MEASUREMENT, 2024, 227
  • [47] Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy
    Woong Kyu Han
    Joon Chae Na
    Sung Yoon Park
    European Radiology, 2020, 30 : 798 - 805
  • [48] Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy
    Han, Woong Kyu
    Na, Joon Chae
    Park, Sung Yoon
    EUROPEAN RADIOLOGY, 2020, 30 (02) : 798 - 805
  • [49] Subjective and objective image quality of low-dose CT images processed using a self-supervised denoising algorithm
    Kimura, Yuya
    Suyama, Takeru Q.
    Shimamura, Yasuteru
    Suzuki, Jun
    Watanabe, Masato
    Igei, Hiroshi
    Otera, Yuya
    Kaneko, Takayuki
    Suzukawa, Maho
    Matsui, Hirotoshi
    Kudo, Hiroyuki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (02) : 367 - 374
  • [50] Image quality and pathology assessment in CT Urography: when is the low-dose series sufficient?
    Kataria, Bharti
    Althen, Nas Nilsson
    Smedby, Orjan
    Persson, Anders
    Sokje, Hannibal
    Sandborg, Michael
    BMC MEDICAL IMAGING, 2019, 19 (01)