Effect of a novel denoising technique on image quality and diagnostic accuracy in low-dose CT in patients with suspected appendicitis

被引:26
|
作者
Kolb, Manuel [1 ]
Storz, Corinna [1 ]
Kim, Jong Hyo [2 ]
Weiss, Jakob [1 ]
Afat, Saif [1 ]
Nikolaou, Konstantin [1 ]
Bamberg, Fabian [1 ]
Othman, Ahmed E. [1 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Radiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Seoul Natl Univ, Dept Radiol, 101 Daehak Ro, Seoul, South Korea
关键词
Tomography; X-Ray computed; Diagnostic imaging; Appendicitis; COMPUTED-TOMOGRAPHY; ABDOMINAL CT; IMPACT; EPIDEMIOLOGY; RELIABILITY; OUTCOMES; PAIN;
D O I
10.1016/j.ejrad.2019.04.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To determine the effect of a vendor unspecific, DICOM-based denoising technique on image quality and diagnostic performance in low-dose simulated abdominal computed tomography (CT) examinations in patients with suspected appendicitis. Methods and Materials: We included 51 patients who underwent contrast-enhanced abdominal CT with Filtered Back Projection due to suspected appendicitis. Realistic Low-Dose simulation generated low-dose datasets at 25% of the original exposition. QuantaStream Denoising, a novel DICOM-based technique denoised the simulated low-Dose datasets. Original (0100), low-dose (LD25) and denoised (DN25) datasets (n = 153) were evaluated regarding subjective image quality (5-point Likert scale; overall quality/image noise/diagnostic confidence), presence/absence of acute appendicitis, free abdominal air and abscess formation and objective image quality (Signal-to-Noise Ratio (SNR) and noise level) by two independent readers. Results: Subjective image quality was rated highest for O100, followed by DN25 and LD25 with significant differences (p = 0.001). Appendicitis was correctly identified in all datasets (n = 30). Appendicitis specific diagnostic confidence was highest for 0100 (p = 0.001), followed by DN25 and LD25 without significant difference. All complications were correctly identified on 0100 and DN25. On LD25, diagnostic accuracy decreased for abscess formations (sensitivity:0.714; specificity:1.0) and for free abdominal air (sensitivity:0.750; specificity:0.936). Regarding noise levels DN25 showed non-inferiority to 0100. SNRs of 0100 and DN25 showed no significant difference (p = 0.06). Conclusion: Our findings indicate that QuantaStream Denoising allows for maintained diagnostic image quality and diagnostic accuracy of low-dose abdominal CT examinations (25% of original exposition) in patients with suspected appendicitis without the need for raw sinogram data.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 50 条
  • [21] Low-Dose Abdominal CT for Evaluating Suspected Appendicitis: Recommendations for CT Imaging Techniques and Practical Issues
    Park, Ji Hoon
    Kim, Hae Young
    Sim, Ji Ye
    Lee, Kyoung Ho
    DIAGNOSTICS, 2022, 12 (07)
  • [22] Iterative reconstruction technique with reduced volume CT dose index: diagnostic accuracy in pediatric acute appendicitis
    Didier, Ryne A.
    Vajtai, Petra L.
    Hopkins, Katharine L.
    PEDIATRIC RADIOLOGY, 2015, 45 (02) : 181 - 187
  • [23] Iterative reconstruction technique with reduced volume CT dose index: diagnostic accuracy in pediatric acute appendicitis
    Ryne A. Didier
    Petra L. Vajtai
    Katharine L. Hopkins
    Pediatric Radiology, 2015, 45 : 181 - 187
  • [24] Diagnostic accuracy of low dose CT-Scan abdomen in patients with clinical features of acute appendicitis
    Asim, Syed Jehanzeb
    Masood, Zubia
    Soomro, Erum
    Qureshi, Abdul Sami
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2024, 40 (09) : 2052 - 2055
  • [25] CoCoDiff: A Contextual Conditional Diffusion Model for Low-dose CT Image Denoising
    Gao, Qi
    Shan, Hongming
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [26] Low-Dose CT Image Denoising with Improving WGAN and Hybrid Loss Function
    Li, Zhihua
    Shi, Weili
    Xing, Qiwei
    Miao, Yu
    He, Wei
    Yang, Huamin
    Jiang, Zhengang
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2021, 2021
  • [27] Spatiotemporal denoising of low-dose cardiac CT image sequences using RecycleGAN
    Zhou, Shiwei
    Yang, Jinyu
    Konduri, Krishnateja
    Huang, Junzhou
    Yu, Lifeng
    Jin, Mingwu
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (06)
  • [28] Low-dose CT: technique, reading methods and image interpretation
    Rampinelli, Cristiano
    Origgi, Daniela
    Bellomi, Massimo
    CANCER IMAGING, 2013, 12 (03): : 548 - 556
  • [29] Low-Dose Abdominal CT for Evaluating Suspected Appendicitis in Adolescents and Young Adults Review of Evidence
    Hoon, Ji
    Salminen, Paulina
    Tannaphai, Penampai
    Lee, Kyoung Ho
    KOREAN JOURNAL OF RADIOLOGY, 2022, 23 (05) : 517 - 528
  • [30] Diagnostic reliability of pediatric appendicitis score, ultrasound and low-dose computed tomography scan in children with suspected acute appendicitis
    Sayed, Ashraf Othman
    Zeidan, Nancy Selim
    Fahmy, Dalia Monir
    Ibrahim, Hossam A.
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2017, 13 : 847 - 854