Effect of a novel denoising technique on image quality and diagnostic accuracy in low-dose CT in patients with suspected appendicitis

被引:26
作者
Kolb, Manuel [1 ]
Storz, Corinna [1 ]
Kim, Jong Hyo [2 ]
Weiss, Jakob [1 ]
Afat, Saif [1 ]
Nikolaou, Konstantin [1 ]
Bamberg, Fabian [1 ]
Othman, Ahmed E. [1 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Radiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Seoul Natl Univ, Dept Radiol, 101 Daehak Ro, Seoul, South Korea
关键词
Tomography; X-Ray computed; Diagnostic imaging; Appendicitis; COMPUTED-TOMOGRAPHY; ABDOMINAL CT; IMPACT; EPIDEMIOLOGY; RELIABILITY; OUTCOMES; PAIN;
D O I
10.1016/j.ejrad.2019.04.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To determine the effect of a vendor unspecific, DICOM-based denoising technique on image quality and diagnostic performance in low-dose simulated abdominal computed tomography (CT) examinations in patients with suspected appendicitis. Methods and Materials: We included 51 patients who underwent contrast-enhanced abdominal CT with Filtered Back Projection due to suspected appendicitis. Realistic Low-Dose simulation generated low-dose datasets at 25% of the original exposition. QuantaStream Denoising, a novel DICOM-based technique denoised the simulated low-Dose datasets. Original (0100), low-dose (LD25) and denoised (DN25) datasets (n = 153) were evaluated regarding subjective image quality (5-point Likert scale; overall quality/image noise/diagnostic confidence), presence/absence of acute appendicitis, free abdominal air and abscess formation and objective image quality (Signal-to-Noise Ratio (SNR) and noise level) by two independent readers. Results: Subjective image quality was rated highest for O100, followed by DN25 and LD25 with significant differences (p = 0.001). Appendicitis was correctly identified in all datasets (n = 30). Appendicitis specific diagnostic confidence was highest for 0100 (p = 0.001), followed by DN25 and LD25 without significant difference. All complications were correctly identified on 0100 and DN25. On LD25, diagnostic accuracy decreased for abscess formations (sensitivity:0.714; specificity:1.0) and for free abdominal air (sensitivity:0.750; specificity:0.936). Regarding noise levels DN25 showed non-inferiority to 0100. SNRs of 0100 and DN25 showed no significant difference (p = 0.06). Conclusion: Our findings indicate that QuantaStream Denoising allows for maintained diagnostic image quality and diagnostic accuracy of low-dose abdominal CT examinations (25% of original exposition) in patients with suspected appendicitis without the need for raw sinogram data.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 23 条
[1]  
Afat S., 2018, RADIOLOGY
[2]   A Deep Learning-Enabled Iterative Reconstruction of Ultra-Low-Dose CT: Use of Synthetic Sinogram-based Noise Simulation Technique [J].
Ahn, Chul Kyun ;
Yang, Zepa ;
Heo, Changyong ;
Jin, Hyeongmin ;
Park, Byungjun ;
Kim, Jong Hyo .
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
[3]   How to Demonstrate Similarity by Using Noninferiority and Equivalence Statistical Testing in Radiology Research [J].
Ahn, Soyeon ;
Park, Seong Ho ;
Lee, Kyoung Ho .
RADIOLOGY, 2013, 267 (02) :328-338
[4]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]   Changing Epidemiology of Acute Appendicitis in the United States: Study Period 1993-2008 [J].
Buckius, Michelle T. ;
McGrath, Brian ;
Monk, John ;
Grim, Rod ;
Bell, Theodore ;
Ahuja, Vanita .
JOURNAL OF SURGICAL RESEARCH, 2012, 175 (02) :185-190
[6]   Acute appendicitis: Epidemiology, treatment and outcomes-analysis of 16544 consecutive cases [J].
Ceresoli, Marco ;
Zucchi, Alberto ;
Allievi, Niccolo ;
Harbi, Asaf ;
Pisano, Michele ;
Montori, Giulia ;
Heyer, Arianna ;
Nita, Gabriela E. ;
Ansaloni, Luca ;
Coccolini, Federico .
WORLD JOURNAL OF GASTROINTESTINAL SURGERY, 2016, 8 (10) :693-699
[7]   Estimating Effective Dose for CT Using Dose-Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning [J].
Christner, Jodie A. ;
Kofler, James M. ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) :881-889
[8]   Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and a Model-based Iterative Reconstruction in Abdominal CT: An Experimental Clinical Study [J].
Deak, Zsuzsanna ;
Grimm, Jochen M. ;
Treitl, Marcus ;
Geyer, Lucas L. ;
Linsenmaier, Ulrich ;
Koerner, Markus ;
Reiser, Maximilian F. ;
Wirth, Stefan .
RADIOLOGY, 2013, 266 (01) :197-206
[9]   How to Treat an Appendiceal Inflammatory Mass: Operatively or Nonoperatively? [J].
Deelder, J. D. ;
Richir, M. C. ;
Schoorl, T. ;
Schreurs, W. H. .
JOURNAL OF GASTROINTESTINAL SURGERY, 2014, 18 (04) :641-645
[10]   Appendicitis in children: Low-dose CT with a phantom-based simulation technique-initial observations [J].
Fefferman, NR ;
Bomsztyk, E ;
Yim, AM ;
Rivera, R ;
Amodio, JB ;
Pinkney, LP ;
Strubel, NA ;
Noz, ME ;
Rusinek, H .
RADIOLOGY, 2005, 237 (02) :641-646