Effect of a novel denoising technique on image quality and diagnostic accuracy in low-dose CT in patients with suspected appendicitis

被引:26
|
作者
Kolb, Manuel [1 ]
Storz, Corinna [1 ]
Kim, Jong Hyo [2 ]
Weiss, Jakob [1 ]
Afat, Saif [1 ]
Nikolaou, Konstantin [1 ]
Bamberg, Fabian [1 ]
Othman, Ahmed E. [1 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Radiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Seoul Natl Univ, Dept Radiol, 101 Daehak Ro, Seoul, South Korea
关键词
Tomography; X-Ray computed; Diagnostic imaging; Appendicitis; COMPUTED-TOMOGRAPHY; ABDOMINAL CT; IMPACT; EPIDEMIOLOGY; RELIABILITY; OUTCOMES; PAIN;
D O I
10.1016/j.ejrad.2019.04.026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To determine the effect of a vendor unspecific, DICOM-based denoising technique on image quality and diagnostic performance in low-dose simulated abdominal computed tomography (CT) examinations in patients with suspected appendicitis. Methods and Materials: We included 51 patients who underwent contrast-enhanced abdominal CT with Filtered Back Projection due to suspected appendicitis. Realistic Low-Dose simulation generated low-dose datasets at 25% of the original exposition. QuantaStream Denoising, a novel DICOM-based technique denoised the simulated low-Dose datasets. Original (0100), low-dose (LD25) and denoised (DN25) datasets (n = 153) were evaluated regarding subjective image quality (5-point Likert scale; overall quality/image noise/diagnostic confidence), presence/absence of acute appendicitis, free abdominal air and abscess formation and objective image quality (Signal-to-Noise Ratio (SNR) and noise level) by two independent readers. Results: Subjective image quality was rated highest for O100, followed by DN25 and LD25 with significant differences (p = 0.001). Appendicitis was correctly identified in all datasets (n = 30). Appendicitis specific diagnostic confidence was highest for 0100 (p = 0.001), followed by DN25 and LD25 without significant difference. All complications were correctly identified on 0100 and DN25. On LD25, diagnostic accuracy decreased for abscess formations (sensitivity:0.714; specificity:1.0) and for free abdominal air (sensitivity:0.750; specificity:0.936). Regarding noise levels DN25 showed non-inferiority to 0100. SNRs of 0100 and DN25 showed no significant difference (p = 0.06). Conclusion: Our findings indicate that QuantaStream Denoising allows for maintained diagnostic image quality and diagnostic accuracy of low-dose abdominal CT examinations (25% of original exposition) in patients with suspected appendicitis without the need for raw sinogram data.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 50 条
  • [1] Low-dose CT for patients with clinically suspected acute appendicitis: optimal strength of sinogram affirmed iterative reconstruction for image quality and diagnostic performance
    Kim, Seung Ho
    Yoon, Jung-Hee
    Lee, Jang Hee
    Lim, Yun-Jung
    Kim, Ok Hwa
    Ryu, Ji Hwa
    Son, Jung-Hee
    ACTA RADIOLOGICA, 2015, 56 (08) : 899 - 907
  • [2] Diagnostic performance and image quality of an image-based denoising algorithm applied to radiation dose-reduced CT in diagnosing acute appendicitis
    Choi, Hyeon Ui
    Cho, Jungheum
    Hwang, Jinhee
    Lee, Seungjae
    Chang, Won
    Park, Ji Hoon
    Lee, Kyoung Ho
    ABDOMINAL RADIOLOGY, 2024, 49 (06) : 1839 - 1849
  • [3] Diagnostic accuracy using low-dose versus standard radiation dose CT in suspected acute appendicitis: prospective cohort study
    Haijanen, Jussi
    Sippola, Suvi
    Tammilehto, Ville
    Gronroos, Juha
    Mantyoja, Siiri
    Loyttyniemi, Eliisa
    Niiniviita, Hannele
    Salminen, Paulina
    BRITISH JOURNAL OF SURGERY, 2021, 108 (12) : 1483 - 1490
  • [4] The Accuracy of Low-dose Computed Tomography Protocol in Patients With Suspected Acute Appendicitis The OPTICAP Study
    Sippola, Suvi
    Virtanen, Johanna
    Tammilehto, Ville
    Gronroos, Juha
    Hurme, Saija
    Niiniviita, Hannele
    Lietzen, Elina
    Salminen, Paulina
    ANNALS OF SURGERY, 2020, 271 (02) : 332 - 338
  • [5] Reduced scan range abdominopelvic CT in patients with suspected acute appendicitis - impact on diagnostic accuracy and effective radiation dose
    Zinsser, Dominik
    Maurer, Michael
    Phuong-Linh Do
    Weiss, Jakob
    Notohamiprodjo, Mike
    Bamberg, Fabian
    Othman, Ahmed E.
    BMC MEDICAL IMAGING, 2019, 19 (1)
  • [6] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Caruso, Damiano
    De Santis, Domenico
    Del Gaudio, Antonella
    Guido, Gisella
    Zerunian, Marta
    Polici, Michela
    Valanzuolo, Daniela
    Pugliese, Dominga
    Persechino, Raffaello
    Cremona, Antonio
    Barbato, Luca
    Caloisi, Andrea
    Iannicelli, Elsa
    Laghi, Andrea
    EUROPEAN RADIOLOGY, 2024, 34 (04) : 2384 - 2393
  • [7] A Novel Total Variation Model for Low-Dose CT Image Denoising
    Chen, Wenbin
    Shao, Yanling
    Wang, Yanling
    Zhang, Quan
    Liu, Yi
    Yao, Linhong
    Chen, Yan
    Yang, Guanru
    Gui, Zhiguo
    IEEE ACCESS, 2018, 6 : 78892 - 78903
  • [8] Diagnostic performance and image quality of deep learning image reconstruction (DLIR) on unenhanced low-dose abdominal CT for urolithiasis
    Delabie, Aurelien
    Bouzerar, Roger
    Pichois, Raphael
    Desdoit, Xavier
    Vial, Jeremie
    Renard, Cedric
    ACTA RADIOLOGICA, 2022, 63 (09) : 1283 - 1292
  • [9] Reduced scan range abdominopelvic CT in patients with suspected acute appendicitis - impact on diagnostic accuracy and effective radiation dose
    Dominik Zinsser
    Michael Maurer
    Phuong-Linh Do
    Jakob Weiß
    Mike Notohamiprodjo
    Fabian Bamberg
    Ahmed E. Othman
    BMC Medical Imaging, 19
  • [10] Feasibility of low-dose unenhanced multi-detector CT in patients with suspected acute appendicitis: comparison with sonography
    Karabulut, Nevzat
    Kiroglu, Yilmaz
    Herek, Duygu
    Kocak, Tevfik Baris
    Erdur, Bulent
    CLINICAL IMAGING, 2014, 38 (03) : 296 - 301