Comparison of Superconducting Fault Current Limiter and Dynamic Voltage Restorer for LVRT Improvement of High Penetration Microgrid

被引:42
|
作者
Chen, Lei [1 ]
Chen, Hongkun [1 ]
Yang, Jun [1 ]
Zhu, Lin [2 ]
Tang, Yi [3 ]
Koh, Leong Hai [3 ]
Xu, Ying [4 ]
Zhang, Chi [4 ]
Liao, Yuxiang [4 ]
Ren, Li [4 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] Univ Tennessee, Dept Elect Engn & Comp Sci, Knoxville, TN 37996 USA
[3] Nanyang Technol Univ, Energy Res Inst, Singapore 639798, Singapore
[4] Huazhong Univ Sci & Technol, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Dynamic voltage restorer (DVR); low-voltage ride-through (LVRT); micro-grid; superconducting fault current limiter (SFCL); techno-economic; RIDE-THROUGH CAPABILITY; DFIG; ENHANCEMENT; PERFORMANCE; SYSTEM;
D O I
10.1109/TASC.2017.2656624
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For a high penetration microgrid, improving its low voltage ride-through (LVRT) capability under some minor or temporary faults can contribute to reinforcing power support and reducing network instability. In this paper, the comparison of a superconducting fault current limiter (SFCL) and a dynamic voltage restorer (DVR) for LVRT capability enhancement of a 10-kV microgrid is conducted. Concerning the microgrid which includes distributed photovoltaic generation, energy storage and loads, the effects of the SFCL and the DVR are compared in detail, and related theoretical analysis, simulation study, and economical evaluation are carried out. From the demonstrated results, the suggested two devices can both assist the microgrid to achieve the LVRT operation, but the economics of the DVR are weaker than the SFCL. Moreover, compared to the DVR, the SFCL enables the energy storage unit to offer better control effects in power stabilization. From technical and economic perspectives, the SFCL is a more preferable choice than the DVR.
引用
收藏
页数:7
相关论文
共 30 条
  • [11] Technical Evaluation of a Superconducting Fault Current Limiter for a Microgrid with Wind-PV Hybrid Generation
    Abdelwahab, Saad A. Mohamed
    Ghoneim, Sherif S. M.
    Hamada, A. M.
    Hasan, Saady
    Khamis, Ragab
    Abdellatif, Walid S. E.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2024, 14 (03): : 538 - 550
  • [12] Low-Voltage Ride-Through (LVRT) Capability Enhancement of DFIG-Based Wind Farm by Using Bridge-Type Superconducting Fault Current Limiter (BTSFCL)
    Firouzi, Mehdi
    Kartijkolaie, Hossein Shahbabaei
    Radmehr, Masoud
    JOURNAL OF POWER TECHNOLOGIES, 2019, 99 (04): : 245 - 253
  • [13] Development of a 1-MVA/1-MJ Superconducting Fault Current Limiter-Magnetic Energy Storage System for LVRT Capability Enhancement and Wind Power Smoothing
    Guo, Wenyong
    Zhang, Guomin
    Zhang, Jingye
    Song, Naihao
    Gao, Zhiyuan
    Xu, Xi
    Jing, Liwei
    Teng, Yuping
    Zhu, Zhiqin
    Xiao, Liye
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (04)
  • [14] Multilevel Cascaded-Type Dynamic Voltage Restorer With Fault Current-Limiting Function
    Jiang, Fei
    Tu, Chunming
    Shuai, Zhikang
    Cheng, Miaomiao
    Lan, Zheng
    Xiao, Fan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (03) : 1261 - 1269
  • [15] Parameter design and performance simulation of a 10 kV voltage compensation type active superconducting fault current limiter
    Chen, L.
    Tang, Y. J.
    Song, M.
    Shi, J.
    Ren, L.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2013, 494 : 349 - 354
  • [16] The Fault Ride-Through Characteristics of a Double-Fed Induction Generator Using a Dynamic Voltage Restorer with Superconducting Magnetic Energy Storage
    Li, Lei
    Liang, Yabo
    Niu, Jian
    He, Jianan
    Liu, Haitao
    Li, Bin
    Li, Chao
    Cao, Yunzhu
    APPLIED SCIENCES-BASEL, 2023, 13 (14):
  • [17] Fault Ride-Through Capability Improvement of Grid Connected PV System Using Dynamic Voltage Restorer
    AbuHussein, Ahmed
    Sadi, Mohammad Ashraf Hossain
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2020, 48 (12-13) : 1296 - 1307
  • [18] Low-cost Non-superconducting DC-fault Current Limiter for the Enhancement of Low-voltage Ride Through Capability of Doubly Fed Induction Generator
    Sahoo, Subhendu Sekhar
    Tripathi, P. M.
    Chatterjee, Kalyan
    IETE TECHNICAL REVIEW, 2020, 37 (04) : 418 - 437
  • [19] Improvement of Fault Ride-Through Capability of Grid Connected Wind Turbine Based on a Switched Reluctance Generator Using a Dynamic Voltage Restorer
    Al Ghamdi, Saeed A.
    SUSTAINABILITY, 2023, 15 (14)
  • [20] Application of a Superconducting Fault Current Limiter to Enhance the Low-Voltage Ride-Through Capability of Wind Turbine Generators
    Lee, Hyeong-Jin
    Lim, Sung-Hun
    Kim, Jae-Chul
    ENERGIES, 2019, 12 (08):