C2 Pedicle Screws Combined With C1 Laminar Hooks for Reducible Atlantoaxial Dislocation: An Ideal Salvage Technique for C1-C2 Pedicle Screws

被引:8
作者
Han, Zhao [1 ]
Yang, Jun [1 ]
Chen, Qunxiang [1 ]
Lu, Xuhua [1 ]
Chen, Fei [1 ]
Guo, Xiang [1 ]
Ni, Bin [1 ]
Guo, Qunfeng [1 ]
机构
[1] Second Mil Med Univ, Changzheng Hosp, Dept Orthoped, 415 Fengyang Rd, Shanghai 200003, Peoples R China
基金
中国国家自然科学基金;
关键词
Reducible; Atlantoaxial instability; Atlantoaxial dislocation; Pedicle screw; Laminar hook; Fixation; Fusion; LATERAL MASS SCREWS; POSTERIOR ARCH; FIXATION; FUSION; ATLAS; PLATE;
D O I
10.1093/ons/opz332
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: A C1 laminar hook can theoretically avoid vertebral artery injury and is less technically demanding. However, only few studies with small samples analyzed the short-term outcomes of C2 pedicle screws combined with C1 laminar hooks (C2PS-C1LH) technique in the treatment of atlantoaxial dislocation. Furthermore, it is not confirmed whether similar clinical outcomes can be achieved with C1-C2 pedicle screw and rod construct (PSRC). OBJECTIVE: To evaluate the outcomes of C2PS-C1LH and C1-C2 PSRC fixation techniques for treating atlantoaxial dislocation. METHODS: Data of 52 patients with atlantoaxial dislocation treated by C1-C2 PSRC or C2PS-C1LH fixation were retrospectively reviewed. Outcomes evaluated by visual analog scale score for neck pain (VASSNP), Neck Disability Index (NDI), atlantodental interval (ADI), and the perioperative parameters including blood loss and operation time were analyzed and compared between 2 techniques. Patient satisfaction at final follow-up was also investigated. RESULTS: There were no complications related to the surgical approach and instrumentation in either group. The mean bone fusion time was 5.06 +/- 1.65 mo for the C2PS-C1LH group and 3.93 +/- 0.99 mo for the C1-C2 PSRC group (P > .05). Hundred percent of fusion rates were achieved in both groups at month 12 after operation. The ADI, VAS scores, the NDI scores, and the JOA scores were greatly improved in both the groups (P < .05), but there were no significant differences between the 2 groups. CONCLUSION: C2PS-C1LH fixation technique was comparable to C1-C2 PSRC in the treatment of reducible atlantoaxial dislocation. C2PS-C1LH fixation was an ideal alternative strategy to C1-C2 PSRC fixation.
引用
收藏
页码:150 / 156
页数:7
相关论文
共 27 条
[1]   Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems [J].
Abumi, K ;
Takada, T ;
Shono, Y ;
Kaneda, K ;
Fujiya, M .
SPINE, 1999, 24 (14) :1425-1434
[2]   Posterior Atlantoaxial Fixation with Screw-Rod Constructs: Safety, Advantages, and Shortcomings [J].
Bhowmick, Deb A. ;
Benzel, Edward C. .
WORLD NEUROSURGERY, 2014, 81 (02) :288-289
[3]   Anatomic Determination of Optimal Entry Point and Direction For C1 Lateral Mass Screw Placement [J].
Blagg, Stuart E. ;
Don, Angus S. ;
Robertson, Peter A. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (04) :233-239
[4]   ATLANTO-AXIAL ARTHRODESIS BY WEDGE COMPRESSION METHOD [J].
BROOKS, AL ;
JENKINS, EB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03) :279-284
[5]   THE INTERSPINAL METHOD OF POSTERIOR ATLANTOAXIAL ARTHRODESIS [J].
DICKMAN, CA ;
SONNTAG, VKH ;
PAPADOPOULOS, SM ;
HADLEY, MN .
JOURNAL OF NEUROSURGERY, 1991, 74 (02) :190-198
[6]   Atlantoaxial Fusion with Screw-Rod Constructs: Meta-Analysis and Review of Literature [J].
Elliott, Robert E. ;
Tanweer, Omar ;
Boah, Akwasi ;
Morsi, Amr ;
Ma, Tracy ;
Smith, Michael L. ;
Frempong-Boadu, Anthony .
WORLD NEUROSURGERY, 2014, 81 (02) :411-421
[7]   Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study [J].
Fensky, Florian ;
Kueny, Rebecca A. ;
Sellenschloh, Kay ;
Pueschel, Klaus ;
Morlock, Michael M. ;
Rueger, Johannes M. ;
Lehmann, Wolfgang ;
Huber, Gerd ;
Hansen-Algenstaedt, Nils .
EUROPEAN SPINE JOURNAL, 2014, 23 (04) :724-731
[8]  
Gallie WE, 1939, Am J Surg, V46, P495, DOI DOI 10.1016/S0002-9610(39)90309-0
[9]   PLATE AND SCREW FIXATION FOR ATLANTOAXIAL SUBLUXATION [J].
GOEL, A ;
LAHERI, V .
ACTA NEUROCHIRURGICA, 1994, 129 (1-2) :47-53
[10]   The use of C1 lateral mass screws in complex cervical spine surgery: Indications, techniques, and outcome in a prospective consecutive series of 25 cases [J].
Gunnarsson, Thorsteinn ;
Massicotte, Eric M. ;
Govender, Preneshlin V. ;
Rampersaud, Yoga Raja ;
Fehlings, Michael G. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (04) :308-316