Modeling and design of a beam emission spectroscopy diagnostic for the negative ion source NIO1

被引:8
作者
Barbisan, M. [1 ]
Zaniol, B. [1 ]
Cavenago, M. [2 ]
Pasqualotto, R. [1 ]
机构
[1] Consorzio RFX Assoc Euratom Enea Fus, I-35127 Padua, Italy
[2] INFN LNL, I-35020 Legnaro, PD, Italy
关键词
Emission spectroscopy - Ion sources - Noninvasive medical procedures - Ion beams;
D O I
10.1063/1.4826325
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Consorzio RFX and INFN-LNL are building a flexible small ion source (Negative Ion Optimization 1, NIO1) capable of producing about 130 mA of H- ions accelerated at 60 KeV. Aim of the experiment is to test and develop the instrumentation for SPIDER and MITICA, the prototypes, respectively, of the negative ion sources and of the whole neutral beam injectors which will operate in the ITER experiment. As SPIDER and MITICA, NIO1 will be monitored with beam emission spectroscopy (BES), a non-invasive diagnostic based on the analysis of the spectrum of the H-alpha emission produced by the interaction of the energetic ions with the background gas. Aim of BES is to monitor direction, divergence, and uniformity of the ion beam. The precision of these measurements depends on a number of factors related to the physics of production and acceleration of the negative ions, to the geometry of the beam, and to the collection optics. These elements were considered in a set of codes developed to identify the configuration of the diagnostic which minimizes the measurement errors. The model was already used to design the BES diagnostic for SPIDER and MITICA. The paper presents the model and describes its application to design the BES diagnostic in NIO1.
引用
收藏
页数:3
相关论文
共 6 条
[1]   Construction of a Versatile Negative Ion Source and Related Developments [J].
Cavenago, M. ;
Serianni, G. ;
Kulevoy, T. ;
Petrenko, S. ;
Agostinetti, P. ;
Antoni, V. ;
Bigi, M. ;
Conventi, D. ;
Fellin, F. ;
Minarello, A. ;
De Muri, M. ;
Pasqualotto, R. ;
Recchia, M. ;
Rigato, M. ;
Sattin, M. ;
Barbisan, M. ;
Rossetto, F. ;
Valente, M. ;
Veltri, P. .
THIRD INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2012), 2013, 1515 :157-166
[2]   Status of NIO1 construction [J].
Cavenago, M. ;
Fagotti, E. ;
Poggi, M. ;
Serianni, G. ;
Antoni, V. ;
Bigi, M. ;
Fellin, F. ;
Gazza, E. ;
Recchia, M. ;
Veltri, P. ;
Petrenko, S. ;
Kulevoy, T. .
SECOND INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES, 2011, 1390
[3]   Recent improvements to the ITER neutral beam system design [J].
Grisham, L. R. ;
Agostinetti, P. ;
Barrera, G. ;
Blatchford, P. ;
Boilson, D. ;
Chareyre, J. ;
Chitarin, G. ;
de Esch, H. P. L. ;
De Lorenzi, A. ;
Franzen, P. ;
Fantz, U. ;
Gagliardi, M. ;
Hemsworth, R. S. ;
Kashiwagi, M. ;
King, D. ;
Krylov, A. ;
Kuriyama, M. ;
Marconato, N. ;
Marcuzzi, D. ;
Roccella, M. ;
Rios, L. ;
Panasenkov, A. ;
Pilan, N. ;
Pavei, M. ;
Rizzolo, A. ;
Sartori, E. ;
Serianni, G. ;
Sonato, P. ;
Pilard, V. ;
Tanaka, M. ;
Tobari, H. ;
Veltri, P. ;
Zaccaria, P. .
FUSION ENGINEERING AND DESIGN, 2012, 87 (11) :1805-1815
[4]   Diagnostics of the ITER neutral beam test facility [J].
Pasqualotto, R. ;
Serianni, G. ;
Sonato, P. ;
Agostini, M. ;
Brombin, M. ;
Croci, G. ;
Dalla Palma, M. ;
De Muri, M. ;
Gazza, E. ;
Gorini, G. ;
Pomaro, N. ;
Rizzolo, A. ;
Spolaore, M. ;
Zaniol, B. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02)
[5]   Design of a beam emission spectroscopy diagnostic for negative ions radio frequency source SPIDER [J].
Zaniol, B. ;
Pasqualotto, R. ;
Barbisan, M. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (04)
[6]   Error evaluation in the spectroscopic measurement of high power beam angular divergence [J].
Zaniol, B. .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2011, 112 (03) :513-518