Surgical Paddle-Lead Placement for Screening Trials of Spinal Cord Stimulation

被引:11
作者
Pahapill, Peter A. [1 ]
机构
[1] United Neurosurg Associates, Naseff Specialty Ctr, St Paul, MN USA
来源
NEUROMODULATION | 2014年 / 17卷 / 04期
关键词
Case series; chronic pain; electrode paddle; SCS; spinal cord stimulation; BACK SURGERY SYNDROME; CONVENTIONAL MEDICAL-MANAGEMENT; NEUROPATHIC PAIN; COST-EFFECTIVENESS; FOLLOW-UP;
D O I
10.1111/ner.12084
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
ObjectivesSpinal cord stimulation (SCS) has become an evidence-based treatment for a variety of chronic pain disorders. A key step in appropriate patient selection and long-term outcome predictability is a percutaneous screening trial of stimulation. Occasionally, a trial cannot be adequately completed with a percutaneous electrode. Rather than depriving this therapy from these patients, the authors have developed a program providing surgically implanted paddle-lead screening trials of SCS. MethodsData from 22 patients undergoing paddle-lead screening trials of SCS from October 2009 to August 2012 were retrospectively reviewed. The surgical paddle leads were positioned with thoracic or cervical laminotomies under local anesthetic and conscious sedation, allowing awakened patients to confirm optimal lead placement. Externalized lead extensions were connected to an external pulse generator for a five-day screening trial. Pain reduction of at least 50% was required for patients to have the previously implanted paddle lead connected to an internalized pulse generator; otherwise, the trial surgical paddle leads were removed. ResultsTwenty-two patients received five-day paddle-lead stimulation screening trials for various chronic neuropathic pain conditions. All paddle screening trials were well tolerated and completed as outpatient procedures. Sixteen patients received fully implanted systems. At an average follow-up of 23 months, all implanted patients continue to have satisfactory pain control. There were no infections, lead migrations, or revisions. ConclusionsSurgically implanted paddle-lead screening trials of SCS can be used safely and effectively in those patients in which an adequate percutaneous-electrode trial cannot be completed. Results are similar to those seen with standard percutaneous screening trials. A systematic approach to surgical-paddle screening trials of SCS has not been previously reported.
引用
收藏
页码:346 / 348
页数:3
相关论文
共 50 条
  • [31] Long-Term Outcomes of Spinal Cord Stimulation With Paddle Leads in the Treatment of Complex Regional Pain Syndrome and Failed Back Surgery Syndrome
    Sears, Nathaniel C.
    Machado, Andre G.
    Nagel, Sean J.
    Deogaonkar, Milind
    Stanton-Hicks, Michael
    Rezai, Ali R.
    Henderson, Jaimie M.
    NEUROMODULATION, 2011, 14 (04): : 312 - 318
  • [32] Cylindrical vs Paddle Leads in Spinal Cord Stimulation for the Long-term Treatment of Chronic Pain: A Systematic Review and Meta-analysis
    El Hadwe, Salim
    Wronowski, Filip
    Rehman, Sara
    Ansong, Yaw Ofosu
    Barone, Damiano G.
    NEUROMODULATION, 2024, 28 (02): : 204 - 233
  • [33] Trends in Clinical Trials for Spinal Cord Stimulation
    Harmsen, Irene E.
    Hasanova, Dilafruz
    Elias, Gavin J. B.
    Boutet, Alexandre
    Neudorfer, Clemens
    Loh, Aaron
    Germann, Jurgen
    Lozano, Andres M.
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2021, 99 (02) : 123 - 134
  • [34] Paddle Lead Spinal Cord Stimulation in the Morbidly Obese Patient Population: Outcomes and Complications in a Single-Surgeon Cohort
    Bharthi, Rosh
    Rogowski, Brandon C.
    Moran, Michael
    Norris, Jordan N.
    Esplin, Nathan
    Tomycz, Nestor D.
    WORLD NEUROSURGERY, 2023, 177 : E532 - E539
  • [35] Spinal cord stimulation with percutaneous leads after loss of coverage with implanted surgical lead
    Yakovlev, Alexander E.
    Resch, Beth E.
    NEUROMODULATION, 2010, 13 (02): : 117 - 120
  • [36] Percutaneous Implanted Paddle Lead for Spinal Cord Stimulation: Technical Considerations and Long-Term Follow-Up
    Kinfe, Thomas M.
    Schu, Stefan
    Quack, Florian J.
    Wille, Christian
    Vesper, Jan
    NEUROMODULATION, 2012, 15 (04): : 402 - 407
  • [37] Spinal Cord Stimulator Paddle Lead Revision and Replacement for Misplaced or Displaced Electrodes
    Mong, Eric R.
    Kethireddy, Saini
    Staudt, Michael D.
    WORLD NEUROSURGERY, 2024, 186 : E432 - E439
  • [38] Cranial Plate Anchoring of Spinal Cord Stimulation Paddle Leads: Technical Note
    Tomycz, Nestor D.
    Cameron, Jeffrey
    Whiting, Donald M.
    Oh, Michael Y.
    NEUROSURGERY, 2012, 71 : 22 - 24
  • [39] Spinal cord stimulation with implanted epidural paddle lead relieves chronic axial low back pain
    Stidd, David A.
    Rivero, Sergio
    Weinand, Martin E.
    JOURNAL OF PAIN RESEARCH, 2014, 7 : 465 - 470
  • [40] Biportal Endoscopic Spinal Cord Stimulation Paddle Lead Implantation: Technical Note and Preliminary Clinical Results
    Miao, Xi-Zi
    Gao, Ding-Zhi
    Yang, Shao-Mei
    Guo, Xiao-Li
    Wen, Ya-Feng
    Shi, Lei
    Chu, Lei
    NEUROMODULATION, 2024, 27 (06): : 1062 - 1067