Surgical Paddle-Lead Placement for Screening Trials of Spinal Cord Stimulation

被引:11
作者
Pahapill, Peter A. [1 ]
机构
[1] United Neurosurg Associates, Naseff Specialty Ctr, St Paul, MN USA
来源
NEUROMODULATION | 2014年 / 17卷 / 04期
关键词
Case series; chronic pain; electrode paddle; SCS; spinal cord stimulation; BACK SURGERY SYNDROME; CONVENTIONAL MEDICAL-MANAGEMENT; NEUROPATHIC PAIN; COST-EFFECTIVENESS; FOLLOW-UP;
D O I
10.1111/ner.12084
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
ObjectivesSpinal cord stimulation (SCS) has become an evidence-based treatment for a variety of chronic pain disorders. A key step in appropriate patient selection and long-term outcome predictability is a percutaneous screening trial of stimulation. Occasionally, a trial cannot be adequately completed with a percutaneous electrode. Rather than depriving this therapy from these patients, the authors have developed a program providing surgically implanted paddle-lead screening trials of SCS. MethodsData from 22 patients undergoing paddle-lead screening trials of SCS from October 2009 to August 2012 were retrospectively reviewed. The surgical paddle leads were positioned with thoracic or cervical laminotomies under local anesthetic and conscious sedation, allowing awakened patients to confirm optimal lead placement. Externalized lead extensions were connected to an external pulse generator for a five-day screening trial. Pain reduction of at least 50% was required for patients to have the previously implanted paddle lead connected to an internalized pulse generator; otherwise, the trial surgical paddle leads were removed. ResultsTwenty-two patients received five-day paddle-lead stimulation screening trials for various chronic neuropathic pain conditions. All paddle screening trials were well tolerated and completed as outpatient procedures. Sixteen patients received fully implanted systems. At an average follow-up of 23 months, all implanted patients continue to have satisfactory pain control. There were no infections, lead migrations, or revisions. ConclusionsSurgically implanted paddle-lead screening trials of SCS can be used safely and effectively in those patients in which an adequate percutaneous-electrode trial cannot be completed. Results are similar to those seen with standard percutaneous screening trials. A systematic approach to surgical-paddle screening trials of SCS has not been previously reported.
引用
收藏
页码:346 / 348
页数:3
相关论文
共 50 条
  • [21] Incidence and Avoidance of Neurologic Complications with Paddle Type Spinal Cord Stimulation Leads
    Levy, Robert
    Henderson, Jaimie
    Slavin, Konstantin
    Simpson, Brian A.
    Barolat, Giancarlo
    Shipley, Jane
    North, Richard
    NEUROMODULATION, 2011, 14 (05): : 412 - 422
  • [22] Techniques for Safe Removal of Spinal Cord Stimulation Paddle Leads
    Topp, Gregory
    Harland, Tessa
    Spurgas, Morgan
    Rock, Andrew
    Pilitsis, Julie G.
    OPERATIVE NEUROSURGERY, 2022, 23 (06) : E348 - E352
  • [23] Techniques to mitigate lead migration for percutaneous trials of cervical spinal cord stimulation
    Finney, Jonathan N.
    Levy, Isaiah R.
    Chandrasekaran, Santosh
    Collinger, Jennifer L.
    Boninger, Michael L.
    Gaunt, Robert A.
    Helm, Eric R.
    Fisher, Lee E.
    FRONTIERS IN SURGERY, 2025, 12
  • [24] Demographic Trends in Paddle Lead Spinal Cord Stimulator Placement: Private Insurance and Medicare Beneficiaries
    Labaran, Lawal
    Bell, Joshua
    Puvanesarajah, Varun
    Jain, Nikhil
    Aryee, Jomar N.
    Raad, Micheal
    Jain, Amit
    Carmouche, Jonathan
    Hassanzadeh, Hamid
    NEUROSPINE, 2020, 17 (02) : 384 - 389
  • [25] Screening trials of spinal cord stimulation for neuropathic pain in England-A budget impact analysis
    Duarte, Rui, V
    Houten, Rachel
    Nevitt, Sarah
    Brookes, Morag
    Bell, Jill
    Earle, Jenny
    Gulve, Ashish
    Thomson, Simon
    Baranidharan, Ganesan
    North, Richard B.
    Taylor, Rod S.
    Eldabe, Sam
    FRONTIERS IN PAIN RESEARCH, 2022, 3
  • [26] Neuromonitoring for Spinal Cord Stimulation Lead Placement Under General Anesthesia
    Shils, Jay L.
    Arle, Jeffrey E.
    JOURNAL OF CLINICAL NEUROLOGY, 2018, 14 (04): : 444 - 453
  • [27] Outcomes of Percutaneous and Paddle Lead Implantation for Spinal Cord Stimulation: A Comparative Analysis of Complications, Reoperation Rates, and Health-Care Costs
    Babu, Ranjith
    Hazzard, Matthew A.
    Huang, Kevin T.
    Ugiliweneza, Beatrice
    Patil, Chirag G.
    Boakye, Maxwell
    Lad, Shivanand P.
    NEUROMODULATION, 2013, 16 (05): : 418 - 426
  • [28] Rate of Complications Following Spinal Cord Stimulation Paddle Electrode Removal
    Maldonado-Naranjo, Andres L.
    Frizon, Leonardo A.
    Sabharwal, Navin C.
    Xiao, Roy
    Hogue, Olivia
    Lobel, Darlene A.
    Machado, Andre G.
    Nagel, Sean J.
    NEUROMODULATION, 2018, 21 (05): : 513 - 519
  • [29] Epidural Anesthesia for Placement of Spinal Cord Stimulators with Paddle-Type Electrodes
    Zhang, Kai
    Bhatia, Sanjay
    Oh, Michael
    Whiting, Donald
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2009, 87 (05) : 292 - 296
  • [30] Psychological Screening/Phenotyping as Predictors for Spinal Cord Stimulation
    Campbell, Claudia M.
    Jamison, Robert N.
    Edwards, Robert R.
    CURRENT PAIN AND HEADACHE REPORTS, 2013, 17 (01)