Soft tissue balancing - The hip

被引:144
作者
Bourne, RB [1 ]
Rorabeck, CH [1 ]
机构
[1] Univ Western Ontario, London Hlth Sci Ctr, Div Orthopaed Surg, London, ON N6A 5A5, Canada
关键词
soft tissue balancing; total hip arthroplasty (THA); leg-length and offset devices;
D O I
10.1054/arth.2002.33263
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
During total hip arthroplasty, femoral offset is restored in only 40% of patients. Increased attention to techniques that ensure leg-length and offset restoration improve total hip arthroplasty function and minimize the risk of complications such as dislocation and limp. Preoperative templating, intraoperative leg-length offset measurements, and the availability of high-offset femoral necks can improve the restoration of offset in 90% of patients.
引用
收藏
页码:17 / 22
页数:6
相关论文
共 30 条
[1]  
ABRAHAM WD, 1992, ORTHOP CLIN N AM, V23, P201
[2]  
BAL S, 1996, AM J ORTHOPSYCHIAT, V25, P61
[3]  
Bourne RB, 2001, CLIN ORTHOP RELAT R, P112
[4]  
Charnley J., 1979, LOW FRICTION ARTHROP
[5]  
Davey J R, 1993, J Arthroplasty, V8, P23
[6]   TELEMETRIC FORCE MEASUREMENTS ACROSS THE HIP AFTER TOTAL ARTHROPLASTY [J].
DAVY, DT ;
KOTZAR, GM ;
BROWN, RH ;
HEIPLE, KG ;
GOLDBERG, VM ;
HEIPLE, KG ;
BERILLA, J ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (01) :45-50
[7]   Measurement of polyethylene wear in acetabular components inserted with and without cement - A randomized trial [J].
Devane, PA ;
Robinson, EJ ;
Bourne, RB ;
Rorabeck, CH ;
Nayak, NN ;
Horne, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (05) :682-689
[8]  
Edeen J, 1995, Am J Orthop (Belle Mead NJ), V24, P347
[9]  
Hodge W A, 1991, J Arthroplasty, V6, P229, DOI 10.1016/S0883-5403(06)80169-5
[10]   MEASUREMENT AND RESTORATION OF EQUALITY IN LENGTH OF THE LOWER-LIMBS IN TOTAL HIP-REPLACEMENT [J].
HOIKKA, V ;
PAAVILAINEN, T ;
LINDHOLM, TS ;
TURULA, KB ;
YLIKOSKI, M .
SKELETAL RADIOLOGY, 1987, 16 (06) :442-446