Compound dual radiation action theory for 252CF brachytherapy

被引:3
作者
Wang, CK [1 ]
Zhang, X [1 ]
机构
[1] Georgia Inst Technol, Nucl & Radiol Engn Program, Neely Res Ctr, Atlanta, GA 30332 USA
关键词
D O I
10.1093/rpd/nch165
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The existing dosimetry protocol that uses the concept of RBE for Cf-252 brachytherapy contains large uncertainties. A new formula has been developed to correlate the biological effect (i.e. cell survival fraction) resulting from a mixed n + gamma radiation field with two physical quantities and two biological quantities. The formula is based on a pathway model evolved from that of the compound-dual-radiation-action (CDRA) theory, previously proposed by Rossi and Zaider. The new model employs the recently published data on radiation-induced DNA lesions. The new formula is capable of predicting quantitatively the synergistic effect caused by the interactions between neutron events and gamma ray events, and it is intended to be included into a new dosimetry protocol for future Cf-252 brachytherapy.
引用
收藏
页码:801 / 806
页数:6
相关论文
共 50 条
[11]   Revision of the 252Cf and D2O-moderated 252Cf reference neutron fields for use in radiation protection dosimetry [J].
Mendez, R. ;
Gomez-Ros, J. M. ;
Thomas, D. J. ;
Thompson, A. K. ;
Bedogni, R. .
RADIATION PHYSICS AND CHEMISTRY, 2021, 184
[12]   Fission dynamics of 252Cf [J].
Zdeb, A. ;
Dobrowolski, A. ;
Warda, M. .
PHYSICAL REVIEW C, 2017, 95 (05)
[13]   Measurement of dose enhancement by neutron capture of boron in 252Cf interstitial brachytherapy [J].
Abd El-Hafez, AI ;
Eissa, HM ;
Eman, SA ;
Fadel, MA .
RADIATION MEASUREMENTS, 1997, 28 (1-6) :441-444
[14]   Derivation of the relative biological effectiveness of high dose rate 252Cf brachytherapy [J].
Rivard, M ;
Zinkin, H ;
Melhus, C .
MEDICAL PHYSICS, 2005, 32 (06) :2063-2063
[15]   Neutrons absorbed dose rate calculations for interstitial brachytherapy with 252Cf sources [J].
Paredes, L. ;
Azorin, J. ;
Balcazar, M. ;
Francois, J. L. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) :582-585
[16]   Dosimetry for 252Cf neutron emitting brachytherapy sources: Protocol, measurements, and calculations [J].
Department of Radiation Oncology, Tufts University School of Medicine, New England Medical Center, #246, 750 Washington Street, Boston, MA 02111, United States .
Med. Phys., 8 (1503-1514)
[17]   RELATIVE BIOLOGICAL EFFECT OF 252CF RADIATION ON HELA CELLS IN CULTURE [J].
FAIRCHILD, RG ;
DREW, RM ;
ATKINS, HL .
RADIOLOGY, 1969, 93 (05) :1187-+
[18]   Dosimetry comparison of LDR 137Cs and LDR 252Cf brachytherapy sources [J].
Melhus, C ;
Zinkin, H ;
Rivard, M .
MEDICAL PHYSICS, 2005, 32 (06) :1951-1951
[19]   Measured gadolinium neutron capture dose enhancement using 252Cf brachytherapy sources [J].
Rivard, MJ ;
Waid, DS ;
Wierzbicki, JG ;
Yudelev, M .
ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 :B430-B435
[20]   Intercomparative studies of brachytherapy techniques combined with 252Cf boron neutron capture therapy [J].
Abd El-Hafez, AI ;
Eissa, HM ;
Eman, SA ;
Fadel, MA .
RADIATION MEASUREMENTS, 1997, 28 (1-6) :435-440