Compound dual radiation action theory for 252CF brachytherapy

被引:3
|
作者
Wang, CK [1 ]
Zhang, X [1 ]
机构
[1] Georgia Inst Technol, Nucl & Radiol Engn Program, Neely Res Ctr, Atlanta, GA 30332 USA
关键词
D O I
10.1093/rpd/nch165
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The existing dosimetry protocol that uses the concept of RBE for Cf-252 brachytherapy contains large uncertainties. A new formula has been developed to correlate the biological effect (i.e. cell survival fraction) resulting from a mixed n + gamma radiation field with two physical quantities and two biological quantities. The formula is based on a pathway model evolved from that of the compound-dual-radiation-action (CDRA) theory, previously proposed by Rossi and Zaider. The new model employs the recently published data on radiation-induced DNA lesions. The new formula is capable of predicting quantitatively the synergistic effect caused by the interactions between neutron events and gamma ray events, and it is intended to be included into a new dosimetry protocol for future Cf-252 brachytherapy.
引用
收藏
页码:801 / 806
页数:6
相关论文
共 50 条
  • [1] Boron dose enhancement for 252Cf brachytherapy
    Allen, BJ
    Ralston, A
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A271 - A274
  • [2] Burst calculations for 252Cf brachytherapy sources
    Rivard, MJ
    MEDICAL PHYSICS, 2000, 27 (12) : 2816 - 2820
  • [3] Neutron dosimetry for a general 252Cf brachytherapy source
    Rivard, MJ
    MEDICAL PHYSICS, 2000, 27 (12) : 2803 - 2815
  • [4] POSSIBLITY OF TUMOR THERAPY WITH 252CF RADIATION
    ATKINS, HL
    ISOTOPES AND RADIATION TECHNOLOGY, 1969, 6 (04): : 410 - &
  • [5] RADIATION PROTECTION FOR SAFE HANDLING OF 252CF SOURCES
    WRIGHT, CN
    HEALTH PHYSICS, 1968, 15 (05): : 466 - +
  • [6] Development of high-activity 252Cf sources for neutron brachytherapy
    Martin, RC
    Laxson, RR
    Miller, JH
    Wierzbicki, JG
    Rivard, MJ
    Marsh, DL
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (10-12) : 1567 - 1570
  • [7] GAMMA DOSE RATE NEAR A NEW 252Cf BRACHYTHERAPY SOURCE
    Fortune, Eugene C.
    Gauld, Ian C.
    Wang, C. -K. Chris
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 73 - 76
  • [8] Physical aspects of HDR 252Cf remote afterloading neutron brachytherapy
    Atkocius, V
    Miller, A
    Atkociene, E
    Kersuliene, M
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A570 - A573
  • [9] NEUTRON RADIOGRAPHY WITH 252CF
    CASON, JL
    SHAW, CB
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1969, 12 (02): : 464 - &
  • [10] Quantitative determination of 252Cf
    Ahmad, I
    Moore, EF
    Greene, JP
    Porter, CE
    Felker, LK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 389 - 392