Mixture distribution and receiver operating characteristic analysis of bedside chest imaging with screen-film and computed radiography

被引:12
作者
Kundel, HL [1 ]
Polansky, M [1 ]
机构
[1] ALLEGHENY UNIV HLTH SCI,SCH PUBL HLTH,PHILADELPHIA,PA 19102
关键词
technology evaluation; mixture distribution analysis; receiver operating characteristic analysis; bedside chest radiography; computed radiography;
D O I
10.1016/S1076-6332(97)80152-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The authors demonstrated the use of mixture distribution analysis as an alternative to receiver operating characteristic (ROC) analysis in a clinical study, where independent verification of the imaging diagnosis is not always feasible. Methods. ROC and mixture distribution analyses were applied to the blind readings of four radiologists on a stratified, random sample of 95 screen-film radiographs and 95 computed radiographs of the chest obtained from a medical intensive care unit. The imaging diagnosis established by an expert panel was used as the truth for the ROC analysis, and agreement of ratings was used for the mixture distribution analysis. Results. Both methods yielded similar values for the proportion of correct diagnoses. Conclusion. Mixture distribution analysis may be useful for comparing imaging techniques in situations where the true imaging diagnosis cannot be established with a method independent of that being evaluated.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 19 条
[1]   QUASI-SYMMETRICAL LATENT CLASS MODELS, WITH APPLICATION TO RATER AGREEMENT [J].
AGRESTI, A ;
LANG, JB .
BIOMETRICS, 1993, 49 (01) :131-139
[2]   CONSENSUS DIAGNOSES AND GOLD STANDARDS - COMMENTARY [J].
BEGG, CB ;
METZ, CE .
MEDICAL DECISION MAKING, 1990, 10 (01) :29-30
[3]  
BEGG CB, 1986, J CHRON DIS, V39, P575
[4]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38
[5]  
EFRON B, 1987, J AM STAT ASSOC, V82, P171, DOI 10.2307/2289144
[6]   USING LATENT CLASS MODELS TO CHARACTERIZE AND ASSESS RELATIVE ERROR IN DISCRETE MEASUREMENTS [J].
ESPELAND, MA ;
HANDELMAN, SL .
BIOMETRICS, 1989, 45 (02) :587-599
[7]   ASSESSMENT OF DIAGNOSTIC TECHNOLOGIES - METHODOLOGY FOR UNBIASED ESTIMATION FROM SAMPLES OF SELECTIVELY VERIFIED PATIENTS [J].
GREENES, RA ;
BEGG, CB .
INVESTIGATIVE RADIOLOGY, 1985, 20 (07) :751-756
[8]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[9]   RECEIVER OPERATOR CHARACTERISTIC (ROC) ANALYSIS WITHOUT TRUTH [J].
HENKELMAN, RM ;
KAY, I ;
BRONSKILL, MJ .
MEDICAL DECISION MAKING, 1990, 10 (01) :24-29
[10]   Prospective study of PACS: Information flow and clinical action in a medical intensive care unit [J].
Kundel, HL ;
Seshadri, SB ;
Langlotz, CP ;
Lanken, PN ;
Horii, SC ;
Nodine, CF ;
Polansky, M ;
Feingold, E ;
Brikman, I ;
Bozzo, M ;
Redfern, R .
RADIOLOGY, 1996, 199 (01) :143-149