Nitric oxide-releasing sol-gel particle/polyurethane glucose biosensors

被引:59
|
作者
Shin, JH [1 ]
Marxer, SM [1 ]
Schoenfisch, MH [1 ]
机构
[1] Univ N Carolina, Dept Chem, Chapel Hill, NC 27599 USA
关键词
D O I
10.1021/ac049776z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hybrid sol-gel/polyurethane glucose biosensor that releases nitric oxide is developed and characterized. The biosensor consists of a platinum electrode coated with four polymeric membranes including the following: (1) sol-gel with immobilized glucose oxidase (GOx); (2) polyurethane to protect the enzyme; (3) NO donormodified sol-gel particle-doped polyurethane; and (4) polyurethane. This configuration was developed due to the drastic reduction in sensitivity observed for NO donormodified sol-gel film-based glucose sensors. For the hybrid sol-gel/polyurethane biosensor, sol-gel particles are first modified with the NO donor and then incorporated into a polyurethane layer that is coated onto the preimmobilized GOx electrode. In this manner, the GOx layer is not exposed to the harsh conditions necessary to impart NO release ability to the biosensor, and only a minimal decrease in sensitivity due to the NO release is observed. The glucose response of the NO-releasing glucose biosensor and its NO generation profiles are reported. In addition, the stability of the sol-gel particles in the supporting polyurethane membrane is discussed.
引用
收藏
页码:4543 / 4549
页数:7
相关论文
共 50 条
  • [1] Sol-gel derived nitric oxide-releasing oxygen sensors
    Marxer, SM
    Robbins, ME
    Schoenfisch, MH
    ANALYST, 2005, 130 (02) : 206 - 212
  • [2] Antibacterial properties of nitric oxide-releasing sol-gel microarrays
    Dobmeier, KP
    Schoenfisch, MH
    BIOMACROMOLECULES, 2004, 5 (06) : 2493 - 2495
  • [3] Synthesis and characterization of nitric oxide-releasing sol-gel microarrays
    Robbins, ME
    Hopper, ED
    Schoenfisch, MH
    LANGMUIR, 2004, 20 (23) : 10296 - 10302
  • [4] In vitro cytotoxicity of nitric oxide-releasing sol-gel derived materials
    Nablo, BJ
    Schoenfisch, MH
    BIOMATERIALS, 2005, 26 (21) : 4405 - 4415
  • [5] In Vivo Analytical Performance of Nitric Oxide-Releasing Glucose Biosensors
    Soto, Robert J.
    Privett, Benjamin J.
    Schoenfisch, Mark H.
    ANALYTICAL CHEMISTRY, 2014, 86 (14) : 7141 - 7149
  • [6] Fabrication of nitric oxide-releasing polyurethane glucose sensor membranes
    Koh, Ahyeon
    Riccio, Daniel A.
    Sun, Bin
    Carpenter, Alexis W.
    Nichols, Scott P.
    Schoenfisch, Mark H.
    BIOSENSORS & BIOELECTRONICS, 2011, 28 (01): : 17 - 24
  • [7] Fabrication of Nitric Oxide-Releasing Porous Polyurethane Membranes-Coated Needle-type Implantable Glucose Biosensors
    Koh, Ahyeon
    Lu, Yuan
    Schoenfisch, Mark H.
    ANALYTICAL CHEMISTRY, 2013, 85 (21) : 10488 - 10494
  • [8] Micropatterninig of nitric oxide (NO)-releasing sol-gel biomaterials.
    Newton, ME
    Marxer, SM
    Schoenfisch, MH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U428 - U428
  • [9] Nitric oxide-releasing sol-gel microarrays prepared with polyethylene glycol acrylate-modified elastomeric templates
    Robbins, ME
    Hopper, ED
    Oh, BK
    Schoenfisch, MH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U701 - U701
  • [10] Nitric oxide releasing sol-gel microarrays for biosensor applications.
    Robbins, ME
    Oh, BK
    Schoenfisch, MH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 227 : U91 - U91