GEMHEP multicenter quality control study of PCR detection of GB virus C hepatitis G virus RNA in serum

被引:22
作者
Bogard, M
BuffetJanvresse, C
Cantaloube, JF
Biagini, P
Duverlie, G
Castelain, S
Izopet, J
Dubois, M
Defer, C
Lepot, I
Coste, J
Marcellin, P
MartinotPeignoux, M
Halfon, P
Gerolami, V
Franguel, L
Pawlotsky, JM
RoudotThoraval, F
Dussaix, E
Loiseau, P
Ravera, N
Lewin, P
Lamoril, J
Lerable, J
Bouchardeau, F
Laperche, S
Mariotti, M
Lefrere, JJ
Nicot, T
Denis, F
Gassain, M
Merel, P
Trepo, C
Thiers, V
Brechot, C
Ferec, C
Mercier, B
StollKeller, F
Palmer, P
Lebon, P
机构
[1] INST NATL TRANSFUS SANGUINE, F-75012 PARIS, FRANCE
[2] CHU ROUEN, ROUEN, FRANCE
[3] CTR HOSP, MEAUX, FRANCE
[4] ETAB TRANSFUS SANGUINE, MARSEILLE, FRANCE
[5] LAB ALPHABIO, MARSEILLE, FRANCE
[6] HOP CONCEPTION, MARSEILLE, FRANCE
[7] CHU AMIENS, AMIENS, FRANCE
[8] CHU TOULOUSE, TOULOUSE, FRANCE
[9] ETS, LILLE, FRANCE
[10] ETS, MONTPELLIER, FRANCE
[11] HOP BEAUJON, CLICHY, FRANCE
[12] CHU PITIE SALPETRIERE, PARIS, FRANCE
[13] ASSISTANCE PUBL HOP PARIS, ETS, PARIS, FRANCE
[14] CHU NECKER, PARIS, FRANCE
[15] HOP ST VINCENT DE PAUL, F-75674 PARIS, FRANCE
[16] CHU HENRI MONDOR, F-94010 CRETEIL, FRANCE
[17] HOP PAUL BROUSSE, VILLEJUIF, FRANCE
[18] LAB CERBA, CERGY, FRANCE
[19] HOP LOUIS MOURIER, F-92701 COLOMBES, FRANCE
[20] CHU LIMOGES, LIMOGES, FRANCE
[21] CHU NANTES, F-44035 NANTES 01, FRANCE
[22] ETS, BORDEAUX, FRANCE
[23] HOP HOTEL DIEU, LYON, FRANCE
[24] ETS BRETAGNE OCCIDENTALE, BREST, BELARUS
[25] CHU STRASBOURG, F-67000 STRASBOURG, FRANCE
关键词
D O I
10.1128/JCM.35.12.3298-3300.1997
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
PCR is, to date, the only available tool for the detection of GB virus C (GBV-C) and hepatitis G virus (HGV) RNAs. Twenty-two French laboratories participated in a quality control study to assess the sensitivity and specificity of their procedures. The panel included 13 positive controls and 7 negative controls. The laboratories used either in-house PCR techniques adapted from the literature or partly standardized commercial tests, Three laboratories performed faultlessly with the entire panel. Most laboratories had excellent specificity (100% in 20 of 22 laboratories), Sensitivity was acceptable (85 to 100%) in 15 centers and insufficient (38 to 77%) in 7, As with nonstandardized in-house PCR, the commercial assays gave discrepant performances in different laboratories. These results suggest that laboratories willing to use PCR for detection of GBV-C/HGV RNA for research or diagnostic purposes should participate in multicenter quality control trials.
引用
收藏
页码:3298 / 3300
页数:3
相关论文
共 21 条
[1]   The cloning and clinical implications of HGV and HGBV-C [J].
Alter, HJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (23) :1536-1537
[2]  
BOUCHARDEAU F, 1994, J VIROL METHODS, V49, P79
[3]   Hepatitis G-associated aplastic anaemia [J].
Byrnes, JJ ;
Banks, AT ;
Piatack, M ;
Kim, JSP .
LANCET, 1996, 348 (9025) :472-472
[4]  
FIORDALISI G, 1996, 9 TRIENN INT S VIR H
[5]  
*GROUP FRANC ET MO, 1994, HEP C VIR NEW DIAGN, P49
[6]   Association between fulminant hepatic failure and a strain of GBV virus C [J].
Heringlake, S ;
Osterkamp, S ;
Trautwein, C ;
Tillmann, HL ;
Boker, K ;
Muerhoff, S ;
Mushahwar, IK ;
Hunsmann, G ;
Manns, MP .
LANCET, 1996, 348 (9042) :1626-1629
[7]   GBV-C/HGV infection and aplastic anaemia [J].
Kao, JH ;
Chen, PJ ;
Lai, MY ;
Chen, DS .
LANCET, 1996, 348 (9033) :1032-1033
[8]   Consensus oligonucleotide primers for the detection of GB virus C in human cryptogenic hepatitis [J].
Leary, TP ;
Muerhoff, AS ;
Simons, JN ;
PilotMatias, TJ ;
Erker, JC ;
Chalmers, ML ;
Schlauder, GG ;
Dawson, GJ ;
Desai, SM ;
Mushahwar, IK .
JOURNAL OF VIROLOGICAL METHODS, 1996, 56 (01) :119-121
[9]  
Leary TP, 1996, J MED VIROL, V48, P60, DOI 10.1002/(SICI)1096-9071(199601)48:1&lt
[10]  
60::AID-JMV10&gt