First clinical experiences with a high field 1.5 T MR linac

被引:85
作者
Bertelsen, Anders S. [1 ]
Schytte, Tine [2 ,3 ]
Moller, Pia K. [2 ,4 ]
Mahmood, Faisal [1 ,3 ]
Riis, Hans L. [1 ,2 ]
Gottlieb, Karina L. [1 ]
Agergaard, Soren N. [1 ]
Dysager, Lars [2 ]
Hansen, Olfred [2 ,3 ]
Gornitzka, Janne [2 ]
Veldhuizen, Elisabeth [1 ]
ODwyer, Dean B. [1 ]
Christiansen, Rasmus L. [1 ,3 ]
Nielsen, Morten [1 ]
Jensen, Henrik R. [1 ]
Brink, Carsten [1 ,3 ]
Bernchou, Uffe [1 ,3 ]
机构
[1] Odense Univ Hosp, Lab Radiat Phys, Odense, Denmark
[2] Odense Univ Hosp, Dept Oncol, Odense, Denmark
[3] Univ Southern Denmark, Dept Clin Res, Odense, Denmark
[4] Odense Univ Hosp, Res Unit Oncol, Odense, Denmark
关键词
GUIDED RADIOTHERAPY; PLAN ADAPTATION; FEASIBILITY; ACCURACY;
D O I
10.1080/0284186X.2019.1627417
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A 1.5 T MR Linac (MRL) has recently become available. MRL treatment workflows (WF) include online plan adaptation based on daily MR images (MRI). This study reports initial clinical experiences after five months of use in terms of patient compliance, cases, WF timings, and dosimetric accuracy. Method and materials: Two different WF were used dependent on the clinical situation of the day; Adapt To Position WF (ATP) where the reference plan position is adjusted rigidly to match the position of the targets and the OARs, and Adapt To Shape WF (ATS), where a new plan is created to match the anatomy of the day, using deformable image registration. Both WFs included three 3D MRI scans for plan adaptation, verification before beam on, and validation during IMRT delivery. Patient compliance and WF timings were recorded. Accuracy in dose delivery was assessed using a cylindrical diode phantom. Results: Nineteen patients have completed their treatment receiving a total of 176 fractions. Cases vary from prostate treatments (60Gy/20F) to SBRT treatments of lymph nodes (45 Gy/3F) and castration by ovarian irradiation (15 Gy/3F). The median session time (patient in to patient out) for 127 ATPs was 26 (21-78) min, four fractions lasted more than 45 min due to additional plan adaptation. For the 49 ATSs a median time of 12 (1-24) min was used for contouring resulting in a total median session time of 42 (29-91) min. Three SBRT fractions lasted more than an hour. The time on the MRL couch was well tolerated by the patients. The median gamma pass rate (2 mm,2% global max) for the adapted plans was 99.2 (93.4-100)%, showing good agreement between planned and delivered dose. Conclusion: MRL treatments, including daily MRIs, plan adaptation, and accurate dose delivery, are possible within a clinically acceptable timeframe and well tolerated by the patients.
引用
收藏
页码:1352 / 1357
页数:6
相关论文
共 25 条
  • [1] Identification of patients with locally advanced pancreatic cancer benefitting from plan adaptation in MR-guided radiation therapy
    Bohoudi, Omar
    Bruynzeel, Anna M. E.
    Meijerink, Martijn R.
    Senan, Suresh
    Slotman, Ben J.
    Palacios, Miguel A.
    Lagerwaard, Frank J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 132 : 16 - 22
  • [2] Christiansen RLD L, 2019, ESTRO 38 CONGRESS
  • [3] Multicentre knowledge sharing and planning/dose audit on flattening filter free beams for SBRT lung
    Hansen, C. R.
    Sykes, J. R.
    Barber, J.
    West, K.
    Bromley, R.
    Szymura, K.
    Fisher, S.
    Sim, J.
    Bailey, M.
    Chrystal, D.
    Deshpande, S.
    Franji, I.
    Nielsen, T. B.
    Brink, C.
    Thwaites, D. I.
    [J]. 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [4] Plan quality and delivery accuracy of flattening filter free beam for SBRT lung treatments
    Hansen, Christian Ronn
    Bertelsen, Anders
    Riis, Hans Lynggaard
    Christiansen, Rasmus Lubeck
    Hansen, Olfred
    Sykes, Jonathan B.
    Thwaites, David Ian
    Brink, Carsten
    [J]. ACTA ONCOLOGICA, 2015, 54 (03) : 422 - 427
  • [5] Performance of a cylindrical diode array for use in a 1.5 T MR-linac
    Houweling, A. C.
    de Vries, J. H. W.
    Wolthaus, J.
    Woodings, S.
    Kok, J. G. M.
    van Asselen, B.
    Smit, K.
    Bel, A.
    Lagendijk, J. J. W.
    Raaymakers, B. W.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03) : N80 - N89
  • [6] The MRI-Linear Accelerator Consortium: Evidence-Based Clinical Introduction of an Innovation in Radiation Oncology Connecting Researchers, Methodology, Data Collection, Quality Assurance, and Technical Development
    Kerkmeijer, Linda G. W.
    Fuller, Clifton D.
    Verkooijen, Helena M.
    Verheij, Marcel
    Choudhury, Ananya
    Harrington, Kevin J.
    Schultz, Chris
    Sahgal, Arjun
    Frank, Steven J.
    Goldwein, Joel
    Brown, Kevin J.
    Minsky, Bruce D.
    van Vulpen, Marco
    [J]. FRONTIERS IN ONCOLOGY, 2016, 6
  • [7] Feasibility and accuracy of quantitative imaging on a 1.5 T MR-linear accelerator
    Kooreman, Ernst S.
    van Houdt, Petra J.
    Nowee, Marlies E.
    van Pelt, Vivian W. J.
    Tijssen, Rob H. N.
    Paulson, Eric S.
    Gurney-Champion, Oliver J.
    Wang, Jihong
    Koetsveld, Folkert
    van Buuren, Laurens D.
    ter Beek, Leon C.
    van der Heide, Uulke A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : 156 - 162
  • [8] The development of the MRI linac system for online MRI-guided radiotherapy: a clinical update
    Lagendijk, J. J. W.
    van Vulpen, M.
    Raaymakers, B. W.
    [J]. JOURNAL OF INTERNAL MEDICINE, 2016, 280 (02) : 203 - 208
  • [9] MRI/linac integration
    Lagendijk, Jan J. W.
    Raaymakers, Bas W.
    Raaijmakers, Alexander J. E.
    Overweg, Johan
    Brown, Kevin J.
    Kerkhof, Ellen M.
    van der Put, Richard W.
    Hardemark, Bjorn
    van Vutpen, Marco
    van der Heide, Uutke A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) : 25 - 29
  • [10] MR guidance in radiotherapy
    Lagendijk, Jan J. W.
    Raaymakers, Bas W.
    Van den Berg, Cornelis A. T.
    Moerland, Marinus A.
    Philippens, Marielle E.
    van Vulpen, Marco
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (21) : R349 - R369