High intensity solid-state UV source for time-gated luminescence microscopy

被引:44
作者
Connally, Russell [1 ]
Jin, Dayong [1 ]
Piper, James [1 ]
机构
[1] Macquarie Univ, Ctr Laser Applicat, Dept Phys, Sydney, NSW 2109, Australia
关键词
UV LED; time-gated luminescence; microscopy; lanthanide; Giardia;
D O I
10.1002/cyto.a.20326
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: The unique discriminative ability of immunofluorescent probes can be severely compromised when probe emission competes against naturally occurring, intrinsically fluorescent substances (autofluorophores). Luminescence microscopes that operate in the time-domain can selectively resolve probes with long fluorescence lifetimes (tau > 100 mu s) against short-lived fluorescence to deliver greatly improved signal-to-noise ratio (SNR). A novel time-gated luminescence microscope design is reported that employs an ultraviolet (UV) light emitting diode (LED) to excite fluorescence from a europium chelate immunoconjugate with a long fluorescence lifetime. Methods: A commercial Zeiss epifluorescence microscope was adapted for TGL operation by fitting with a time-gated image-intensified CCD camera and a high-power (100 mW) UV LED. Capture of the luminescence was delayed for a precise interval following excitation so that autofluorescence was suppressed. Giardia cysts were labeled in situ with antibody conjugated to a europium chelate (BHHST) with a fluorescence lifetime > 500 mu s. Results: BHHST-labeled Giardia cysts emit at 617 nm when excited in the UV and were difficult to locate within the matrix of fluorescent algae using conventional fluorescence microscopy, and the SNR of probe to aurofluorescent background was 0.51:1. However in time-gated luminescence mode with a gate-delay of 5 mu s, the SNR was improved to 12.8:1, a 25-fold improvement. Conclusion: In comparison to xenon flashlamps, UV LEDs are inexpensive, easily powered, and extinguish quickly. Furthermore, the spiked emission of the LED enabled removal of spectral filters from the microscope to significantly improve efficiency of fluorescence excitation and capture.
引用
收藏
页码:1020 / 1027
页数:8
相关论文
共 23 条
  • [11] Correlation between the lowest triplet state energy level of the ligand and lanthanide(III) luminescence quantum yield
    Latva, M
    Takalo, H
    Mukkala, VM
    Matachescu, C
    RodriguezUbis, JC
    Kankare, J
    [J]. JOURNAL OF LUMINESCENCE, 1997, 75 (02) : 149 - 169
  • [12] LUMINESCENT POLYAMINOCARBOXYLATE CHELATES OF TERBIUM AND EUROPIUM - THE EFFECT OF CHELATE STRUCTURE
    LI, M
    SELVIN, PR
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1995, 117 (31) : 8132 - 8138
  • [13] Luminescence properties of defects in GaN -: art. no. 061301
    Reshchikov, MA
    Morkoç, H
    [J]. JOURNAL OF APPLIED PHYSICS, 2005, 97 (06)
  • [14] Luminescence in GaN co-doped with carbon and silicon
    Seager, CH
    Tallant, DR
    Yu, J
    Götz, W
    [J]. JOURNAL OF LUMINESCENCE, 2004, 106 (02) : 115 - 124
  • [15] TIME-RESOLVED FLUORESCENCE IMAGING OF EUROPIUM CHELATE LABEL IN IMMUNOHISTOCHEMISTRY AND INSITU HYBRIDIZATION
    SEVEUS, L
    VAISALA, M
    SYRJANEN, S
    SANDBERG, M
    KUUSISTO, A
    HARJU, R
    SALO, J
    HEMMILA, I
    KOJOLA, H
    SOINI, E
    [J]. CYTOMETRY, 1992, 13 (04): : 329 - 338
  • [16] A new technique for multiparameter imaging microscopy: Use of long decay time photoluminescent labels enables multiple color immunocytochemistry with low channel-to-channel crosstalk
    Soini, AE
    Kuusisto, A
    Meltola, NJ
    Soini, E
    Seveus, L
    [J]. MICROSCOPY RESEARCH AND TECHNIQUE, 2003, 62 (05) : 396 - 407
  • [17] LANTHANIDE CHELATES AS NEW FLUOROCHROME LABELS FOR CYTO-CHEMISTRY
    SOINI, EJ
    PELLINIEMI, LJ
    HEMMILA, IA
    MUKKALA, VM
    KANKARE, JJ
    FROJDMAN, K
    [J]. JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1988, 36 (11) : 1449 - 1451
  • [18] SIMULTANEOUS MEASUREMENT OF FLUORESCENCE AND PHOSPHORESCENCE USING SYNCHRONOUSLY GATED PHOTON COUNTERS
    SUTHERLAND, JC
    CIMINO, GD
    DESMOND, EJ
    [J]. ANALYTICAL BIOCHEMISTRY, 1979, 97 (01) : 158 - 165
  • [19] TAKALO H, 1993, Patent No. 9311433
  • [20] Temporally and spectrally resolved imaging microscopy of lanthanide chelates
    Vereb, G
    Jares-Erijman, E
    Selvin, PR
    Jovin, TM
    [J]. BIOPHYSICAL JOURNAL, 1998, 74 (05) : 2210 - 2222