Continuous Noninvasive Hemoglobin Measurement Is Useful in Patients Undergoing Double-Jaw Surgery

被引:9
作者
Kim, Sung-Hoon [1 ]
Choi, Jae Moon [1 ]
Kim, Hyun Jeong [2 ,3 ]
Choi, Seong-Soo [1 ]
Choi, In Cheol [1 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Anesthesiol & Pain Med, Seoul 138736, South Korea
[2] Seoul Natl Univ, Dept Dent Anesthesiol, Seoul, South Korea
[3] Seoul Natl Univ, Sch Dent, Dent Res Inst, Seoul, South Korea
关键词
PULSE CO-OXIMETRY; HYPOTENSIVE ANESTHESIA; SPINE SURGERY; ACCURACY;
D O I
10.1016/j.joms.2014.03.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Continuous measurement of hemoglobin by pulse CO-oximetry (SpHb; Masimo Radical 7 device, Masimo Corp, Irvine, CA) may be helpful during double-jaw surgery when massive hemorrhage is anticipated. Given the possible influence of low blood pressure on the detection of hemoglobin levels, the agreement of the SpHb was evaluated in patients undergoing orthognathic surgery when using hypotensive anesthesia. Materials and Methods: Patients who underwent elective Le Fort I osteotomy and bilateral sagittal split ramus osteotomy (BSSO) were enrolled in this observational prospective cohort study. SpHb was compared with time-matched arterial total hemoglobin (tHb) before incision, at Le Fort I osteotomy, at BSSO, and at skin closure. The correlation between simultaneous SpHb and tHb measurement pairs was evaluated. Agreement was assessed by a comparison of SpHb with tHb using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. Results: The average age of 51 patients was 23 +/- 5 years and 32 patients were male. The correlations of SpHb and tHb measurements were 0.72, 0.85, 0.89, and 0.78 before incision, at Le Fort I osteotomy, at BSSO, and at closure, respectively. Bland-Altman analysis for SpHb and tHb showed respective bias values of 0.12, 0.07, -0.09, and -0.90 g/dL. ICC values between SpHb and tHb were 0.82, 0.90, 0.91, and 0.87, respectively. Conclusions: Continuous monitoring of hemoglobin may help to determine the appropriate time to perform an invasive measurement of hemoglobin in patients who undergo double-jaw surgery. (C) 2014 American Association of Oral and Maxillofacial Surgeons
引用
收藏
页码:1813 / 1819
页数:7
相关论文
共 18 条
[1]   Evaluation of Pulse Cooximetry in Patients Undergoing Abdominal or Pelvic Surgery [J].
Applegate, Richard L., II ;
Barr, Steven J. ;
Collier, Carl E. ;
Rook, James L. ;
Mangus, Dustin B. ;
Allard, Martin W. .
ANESTHESIOLOGY, 2012, 116 (01) :65-72
[2]   The Accuracy of Noninvasive Hemoglobin Measurement by Multiwavelength Pulse Oximetry After Cardiac Surgery [J].
Ba-Vinh Nguyen ;
Vincent, Jean-Louis ;
Nowak, Emmanuel ;
Coat, Michelle ;
Paleiron, Nicolas ;
Gouny, Pierre ;
Ould-Ahmed, Mehdi ;
Guillouet, Maite ;
Arvieux, Charles Christian ;
Gueret, Gildas .
ANESTHESIA AND ANALGESIA, 2011, 113 (05) :1052-1057
[3]   Continuous Noninvasive Hemoglobin Monitoring During Complex Spine Surgery [J].
Berkow, Lauren ;
Rotolo, Stephanie ;
Mirski, Erin .
ANESTHESIA AND ANALGESIA, 2011, 113 (06) :1396-1402
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
Butterworth JF, 2013, MORGAN MIKHAILS CLIN, P262
[6]   Non-invasive haemoglobin measurement in patients undergoing elective Caesarean section [J].
Butwick, A. ;
Hilton, G. ;
Carvalho, B. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (02) :271-277
[7]   The effect of hypotensive anesthesia on blood loss and operative time during Le Fort I osteotomies [J].
Dolman, RM ;
Bentley, KC ;
Head, TW ;
English, M .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 58 (08) :834-839
[8]   Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients [J].
Frasca, Denis ;
Dahyot-Fizelier, Claire ;
Catherine, Karen ;
Levrat, Quentin ;
Debaene, Bertrand ;
Mimoz, Olivier .
CRITICAL CARE MEDICINE, 2011, 39 (10) :2277-2282
[9]   Comparison of the Accuracy of Noninvasive Hemoglobin Monitoring by Spectrophotometry (SpHb) and HemoCue® with Automated Laboratory Hemoglobin Measurement [J].
Lamhaut, Lionel ;
Apriotesei, Roxana ;
Combes, Xavier ;
Lejay, Marc ;
Carli, Pierre ;
Vivien, Benoit .
ANESTHESIOLOGY, 2011, 115 (03) :548-554
[10]   The Accuracy of Noninvasive and Continuous Total Hemoglobin Measurement by Pulse CO-Oximetry in Human Subjects Undergoing Hemodilution [J].
Macknet, Mark R. ;
Allard, Martin ;
Applegate, Richard L. ;
Rook, James .
ANESTHESIA AND ANALGESIA, 2010, 111 (06) :1424-1426