Survey of Window-Opening Behavior of Severe Cold Area in Winter and Relevant Energy Consumption Analysis

被引:2
作者
Huang, Kailiang [1 ,2 ]
Feng, Guohui [1 ]
Zhao, Lei [1 ]
Chang, Shasha [1 ]
Jiang, Mingzhi [1 ]
机构
[1] Shenyang Jianzhu Univ, Sch Municipal & Environm Engn, Shenyang 110168, Peoples R China
[2] Chongqing Univ, Fac Urban Construct & Environm Engn, Chongqing 400030, Peoples R China
来源
PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 3: BUILDING SIMULATION AND INFORMATION MANAGEMENT | 2014年 / 263卷
关键词
Window-opening; Severe cold area; Energy consumption; Air change rate; NATURAL VENTILATION; SINGLE;
D O I
10.1007/978-3-642-39578-9_55
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In severe cold area with district heating, residents generally rely on window-opening behavior to improve indoor air quality, while heat loss becomes serious due to great temperature difference of inside and outside. Firstly, this paper acquired the basic information of Shenyang residential window-opening behavior though means of questionnaire. The second step is a comprehensive analysis using tracer gas measurement, computational fluid dynamics, and empirical models to acquire air change rate for typical rooms under conditions including window-opening custom and meteorological parameters. Based on all that, ventilation mass of a family apartment is predicted, and furthermore, we determined the ratio of the energy consumption to window-opening behavior in the coldest month. The research shows that most residents in Shenyang pay attention to indoor air quality and has window-opening behavior for certain time, and the present residential ventilation strategy is not only energy unfriendly but also unhealthy. This study provides important fundamental information for further ventilation strategy optimization in serve cold zone in China.
引用
收藏
页码:523 / 533
页数:11
相关论文
共 17 条
  • [1] [Anonymous], 2010, CHINA BUILDING ENERG
  • [2] [Anonymous], 1999, CHIN STAT YB 1999 20
  • [3] [Anonymous], 2010, 262010 JGJ
  • [4] MEASUREMENT OF TURBULENCE WITH THE LASER-DOPPLER ANEMOMETER
    BUCHHAVE, P
    GEORGE, WK
    LUMLEY, JL
    [J]. ANNUAL REVIEW OF FLUID MECHANICS, 1979, 11 : 443 - 503
  • [5] Numerical simulation of single-sided ventilation using RANS and LES and comparison with full-scale experiments
    Caciolo, Marcello
    Stabat, Pascal
    Marchio, Dominique
    [J]. BUILDING AND ENVIRONMENT, 2012, 50 : 202 - 213
  • [6] Full scale experimental study of single-sided ventilation: Analysis of stack and wind effects
    Caciolo, Marcello
    Stabat, Pascal
    Marchio, Dominique
    [J]. ENERGY AND BUILDINGS, 2011, 43 (07) : 1765 - 1773
  • [7] Charlesworth PS., 1988, AIR EXCHANGE RATE AI
  • [8] Lagus P., 1985, ASHRAE T, V91, P1075
  • [9] Investigation of indoor air quality at residential homes in Hong Kong - case study
    Lee, SC
    Li, WM
    Ao, CH
    [J]. ATMOSPHERIC ENVIRONMENT, 2002, 36 (02) : 225 - 237
  • [10] Li Jingmei, 2008, J HVAC, V38, P111