A study of fouling and its effects on the performance of counter flow wet cooling towers

被引:21
|
作者
Khan, JUR [1 ]
Zubair, SM [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Mech Engn, Dhahran 31261, Saudi Arabia
关键词
cooling towers; performance; fill fouling model;
D O I
10.1243/095440804322860636
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Fouling of fills is one of the most important factors affecting cooling tower thermal performance, reducing the effectiveness and capability of the cooling tower. In this paper, experimental data on fill fouling that have been reported in the literature are used to develop a fouling model. The model predicts the decrease in the fill performance index, eta(F), with the growth of fouling on fill materials. The authenticity of the fouling model is validated by experimental data. The fouling model, in conjunction with a detailed model of a counterflow wet cooling tower, is used to study the effect of fouling on cooling tower effectiveness and water outlet temperature. The models are used for studying the performance of small and medium-sized cooling towers under different air inlet wet-bulb temperatures. The results demonstrate that fouling of fills negates any gains in cooling tower performance that result from decreasing values of air inlet wet-bulb temperature. Furthermore, it is demonstrated that this effect is more pronounced in medium-sized cooling towers compared with small towers. Water outlet temperature decreases by 23.5 per cent in the case of small cooling towers, compared with an 18.3 per cent decrease for medium-sized towers under similar operating conditions.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 50 条
  • [21] Thermal performance of cross flow cooling towers in variable wet bulb temperature
    Hajidavalloo, Ebrahim
    Shakeri, Reza
    Mehrabian, Mozaffar A.
    ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (06) : 1298 - 1303
  • [22] Experimental study of cross walls effect on the performance of wet cooling towers
    School of Energy and Power Engineering, Shandong University, Jinan 250061, Shandong Province, China
    Zhongguo Dianji Gongcheng Xuebao, 2012, 11 (28-34):
  • [23] ON THE ANALYSIS OF COUNTER-FLOW COOLING-TOWERS
    OSTERLE, F
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1991, 34 (4-5) : 1313 - 1316
  • [24] The Lewis factor and its influence on the performance prediction of wet-cooling towers
    Kloppers, JC
    Kröger, DG
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2005, 44 (09) : 879 - 884
  • [25] Effect of Thermal Load on Evaporation Loss of Natural Draft Counter-Flow Wet Cooling Towers
    Yuan, Wei
    Sun, Fengzhong
    Chen, Xuehong
    Liu, Ruqing
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2020, 12 (05)
  • [26] COUNTER- AND CROSS-FLOW COOLING TOWERS
    MOLYNEUX, F
    CHEMICAL AND PROCESS ENGINEERING, 1967, 48 (05): : 56 - &
  • [27] THEORETICAL AND EXPERIMENTAL STUDY OF THERMAL PERFORMANCE WITHIN A COUNTER-FLOW WET COOLING TOWER
    Meneceur, N.
    Boulahrouz, S.
    Khounfais, K.
    Boukhari, A.
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2018, 13 (11) : 3691 - 3709
  • [28] Comprehensive coupling model of counter-flow wet cooling tower and its thermal performance analysis
    Yu, J. H.
    Qu, Z. G.
    Zhang, J. F.
    Hu, S. J.
    Guan, J.
    ENERGY, 2022, 238
  • [29] Numerical analysis of a counter-flow wet cooling tower and its plume
    Zargar A.
    Kodkani A.
    Peris A.
    Clare E.
    Cook J.
    Karupothula P.
    Vickers B.
    Flynn M.R.
    Secanell M.
    International Journal of Thermofluids, 2022, 14
  • [30] AN ANALYTICAL MODEL ON THERMAL PERFORMANCE EVALUATION OF COUNTER FLOW WET COOLING TOWER
    Wang, Qian
    Wang, Pei-Hong
    Su, Zhi-Gang
    THERMAL SCIENCE, 2017, 21 (06): : 2491 - 2501