Development of low-energy X-ray detectors using LGAD sensors

被引:24
作者
Andra, Marie [1 ]
Zhang, Jiaguo [1 ]
Bergamaschi, Anna [1 ]
Barten, Rebecca [1 ]
Borca, Camelia [1 ]
Borghi, Giacomo [2 ]
Boscardin, Maurizio [2 ]
Busca, Paolo [3 ]
Bruckner, Martin [1 ]
Cartiglia, Nicolo [4 ]
Chiriotti, Sabina [1 ]
Dalla Betta, Gian-Franco [5 ]
Dinapoli, Roberto [1 ]
Fajardo, Pablo [3 ]
Ferrero, Marco [4 ]
Ficorella, Francesco [2 ]
Frojdh, Erik [1 ]
Greiffenberg, Dominic [1 ]
Huthwelker, Thomas [1 ]
Lopez-Cuenca, Carlos [1 ]
Meyer, Markus [1 ]
Mezza, Davide [1 ]
Mozzanica, Aldo [1 ]
Pancheri, Lucio [5 ]
Paternoster, Giovanni [2 ]
Redford, Sophie [1 ]
Ruat, Marie [3 ]
Ruder, Christian [1 ]
Schmitt, Bernd [1 ]
Shi, Xintian [1 ]
Sola, Valentina [4 ]
Thattil, Dhanya [1 ]
Tinti, Gemma [1 ]
Vetter, Seraphin [1 ]
机构
[1] Paul Scherrer Inst, Forschungsstr 111, CH-5232 Villigen, Switzerland
[2] Fdn Bruno Kessler, Via Sommar 18, I-38123 Trento, Italy
[3] European Synchrotron Radiat Facil, Grenoble, France
[4] INFN Torino, Via Pietro Giuria 1, I-10125 Turin, Italy
[5] Univ Trento, Via Sommar 9, I-38123 Trento, Italy
关键词
hybrid detectors; silicon detectors; low gain avalanche detectors; single photon counting; PHOTODIODES; SILICON; PILATUS; NOISE;
D O I
10.1107/S1600577519005393
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent advances in segmented low-gain avalanche detectors (LGADs) make them promising for the position-sensitive detection of low-energy X-ray photons thanks to their internal gain. LGAD microstrip sensors fabricated by Fondazione Bruno Kessler have been investigated using X-rays with both charge-integrating and single-photon-counting readout chips developed at the Paul Scherrer Institut. In this work it is shown that the charge multiplication occurring in the sensor allows the detection of X-rays with improved signal-to-noise ratio in comparison with standard silicon sensors. The application in the tender X-ray energy range is demonstrated by the detection of the sulfur K-alpha and K-beta lines (2.3 and 2.46keV) in an energy-dispersive fluorescence spectrometer at the Swiss Light Source. Although further improvements in the segmentation and in the quantum efficiency at low energy are still necessary, this work paves the way for the development of single-photon-counting detectors in the soft X-ray energy range.
引用
收藏
页码:1226 / 1237
页数:12
相关论文
共 45 条
  • [21] On the influence of crystal size and wavelength on native SAD phasing
    Liebschner, Dorothee
    Yamada, Yusuke
    Matsugaki, Naohiro
    Senda, Miki
    Senda, Toshiya
    [J]. ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2016, 72 : 728 - 741
  • [22] Lutz G, 2007, SEMICONDUCTOR RAD DE
  • [23] IMPACT IONIZATION IN SILICON - A REVIEW AND UPDATE
    MAES, W
    DEMEYER, K
    VANOVERSTRAETEN, R
    [J]. SOLID-STATE ELECTRONICS, 1990, 33 (06) : 705 - 718
  • [24] MULTIPLICATION NOISE IN UNIFORM AVALANCHE DIODES
    MCINTYRE, RJ
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 1966, ED13 (01) : 164 - +
  • [25] Characterization results of the JUNGFRAU full scale readout ASIC
    Mozzanica, A.
    Bergamaschi, A.
    Brueckner, M.
    Cartier, S.
    Dinapoli, R.
    Greiffenberg, D.
    Jungmann-Smith, J.
    Maliakal, D.
    Mezza, D.
    Ramilli, M.
    Ruder, C.
    Schaedler, L.
    Schmitt, B.
    Shi, X.
    Tinti, G.
    [J]. JOURNAL OF INSTRUMENTATION, 2016, 11
  • [26] The GOTTHARD charge integrating readout detector: design and characterization
    Mozzanica, A.
    Bergamaschi, A.
    Dinapoli, R.
    Graafsma, H.
    Greiffenberg, D.
    Henrich, B.
    Johnson, I.
    Lohmann, M.
    Valeria, R.
    Schmitt, B.
    Xintian, S.
    [J]. JOURNAL OF INSTRUMENTATION, 2012, 7
  • [27] MythenII: A 128 channel single photon counting readout chip
    Mozzanica, Aldo
    Bergamaschi, Anna
    Dinapoli, Roberto
    Gozzo, Fabia
    Henrich, Beat
    Kraft, Philipp
    Patterson, Bruce
    Schmitt, Bernd
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01) : 250 - 252
  • [28] Table-top Soft X-ray Microscopy with a Laser-induced Plasma Source Based on a Pulsed Gas-jet
    Mueller, Matthias
    Mey, Tobias
    Niemeyer, Juergen
    Lorenz, Maike
    Mann, Klaus
    [J]. ICXOM23: INTERNATIONAL CONFERENCE ON X-RAY OPTICS AND MICROANALYSIS, 2016, 1764
  • [29] A high sensitivity ultralow temperature RF conductance and noise measurement setup
    Parmentier, F. D.
    Mahe, A.
    Denis, A.
    Berroir, J. -M.
    Glattli, D. C.
    Placais, B.
    Feve, G.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (01)
  • [30] Developments and first measurements of Ultra-Fast Silicon Detectors produced at FBK
    Paternoster, G.
    Arcidiacono, R.
    Boscardin, M.
    Cartiglia, N.
    Cenna, F.
    Dalla Betta, G. F.
    Ferrero, M.
    Mulargia, R.
    Obertino, M.
    Pancheri, L.
    Piemonte, C.
    Sola, V.
    [J]. JOURNAL OF INSTRUMENTATION, 2017, 12