Early anti-correlated BOLD signal changes of physiologic origin

被引:28
作者
Bright, Molly G. [1 ,2 ]
Bianciardi, Marta [1 ,3 ]
de Zwart, Jacco A. [1 ]
Murphy, Kevin [2 ]
Duyn, Jeff H. [1 ]
机构
[1] NINDS, Adv MRI Sect, LFMI, NIH, Bethesda, MD 20892 USA
[2] Cardiff Univ, Sch Psychol, CUBRIC, Cardiff CF10 3AT, S Glam, Wales
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol,Athinoula A Martinos Ctr Biomed Imagi, Boston, MA USA
基金
英国惠康基金;
关键词
fMRI; Negative BOLD; Anti-correlated BOLD; Physiology; Respiratory challenge; Deactivation; PRIMARY SOMATOSENSORY CORTEX; SENSORY STIMULATION; FMRI SIGNALS; BLOOD-FLOW; BRAIN; FLUCTUATIONS; HYPERCAPNIA; ACTIVATION; DYNAMICS; CONTRAST;
D O I
10.1016/j.neuroimage.2013.10.055
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Negative BOLD signals that are synchronous with resting state fluctuations have been observed in large vessels in the cortical sulci and surrounding the ventricles. In this study, we investigated the origin of these negative BOLD signals by applying a Cued Deep Breathing (COB) task to create transient hypocapnia and a resultant global fMRI signal decrease. We hypothesized that a global stimulus would amplify the effect in large vessels and that using a global negative (vasoconstrictive) stimulus would test whether these voxels exhibit either inherently negative or simply anti-correlated BOLD responses. Significantly anti-correlated, but positive, BOLD signal changes during respiratory challenges were identified in voxels primarily located near edges of brain spaces containing CSF. These positive BOLD responses occurred earlier than the negative COB response across most of gray matter voxels. These findings confirm earlier suggestions that in some brain regions, local, fractional changes in CSF volume may overwhelm BOLD-related signal changes, leading to signal anti-correlation. We show that regions with CDB anti-correlated signals coincide with most, but not all, of the regions with negative BOLD signal changes observed during a visual and motor stimulus task. Thus, the addition of a physiological challenge to fMRI experiments can help identify which negative BOLD signals are passive physiological anti-correlations and which may have a putative neuronal origin. Published by Elsevier Inc.
引用
收藏
页码:287 / 296
页数:10
相关论文
共 35 条
[1]   TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION [J].
BANDETTINI, PA ;
WONG, EC ;
HINKS, RS ;
TIKOFSKY, RS ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) :390-397
[2]   Negative BOLD-fMRI signals in large cerebral veins [J].
Bianciardi, Marta ;
Fukunaga, Masaki ;
van Gelderen, Peter ;
de Zwart, Jacco A. ;
Duyn, Jeff H. .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2011, 31 (02) :401-412
[3]   The respiration response function: The temporal dynamics of fMRI signal fluctuations related to changes in respiration [J].
Birn, Rasmus M. ;
Smith, Monica A. ;
Jones, Tyler B. ;
Bandettini, Peter A. .
NEUROIMAGE, 2008, 40 (02) :644-654
[4]   An Improved Method for Acquiring Cerebrovascular Reactivity Maps [J].
Blockley, Nicholas P. ;
Driver, Ian D. ;
Francis, Susan T. ;
Fisher, Joseph A. ;
Gowland, Penny A. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) :1278-1286
[5]   MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS [J].
BOXERMAN, JL ;
HAMBERG, LM ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :555-566
[6]   Carbon dioxide and the cerebral circulation [J].
Brian, JE .
ANESTHESIOLOGY, 1998, 88 (05) :1365-1386
[7]  
Bright M.G., 2011, 11 ANN M INT SOC MAG
[8]   Removing motion and physiological artifacts from intrinsic BOLD fluctuations using short echo data [J].
Bright, Molly G. ;
Murphy, Kevin .
NEUROIMAGE, 2013, 64 :526-537
[9]   Characterization of regional heterogeneity in cerebrovascular reactivity dynamics using novel hypocapnia task and BOLD fMRI [J].
Bright, Molly G. ;
Bulte, Daniel P. ;
Jezzard, Peter ;
Duyn, Jeff H. .
NEUROIMAGE, 2009, 48 (01) :166-175
[10]   Dynamics of blood flow and oxygenation changes during brain activation: The balloon model [J].
Buxton, RB ;
Wong, EC ;
Frank, LR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :855-864