Indoor environmental pollutants and their association with sick house syndrome among adults and children in elementary school

被引:28
作者
Kishi, Reiko [1 ]
Ketema, Rahel Mesfin [1 ,2 ]
Bamai, Yu Ait [1 ]
Araki, Atsuko [1 ]
Kawai, Toshio [3 ]
Tsuboi, Tazuru [3 ]
Saito, Ikue [4 ]
Yoshioka, Eiji [5 ]
Saito, Takeshi [2 ]
机构
[1] Hokkaido Univ, Ctr Environm & Hlth Sci, Sapporo, Hokkaido, Japan
[2] Hokkaido Univ, Grad Sch Hlth Sci, Sapporo, Hokkaido, Japan
[3] Japan Ind Safety & Hlth Assoc, Osaka Occupat Hlth Serv Ctr, Osaka, Japan
[4] Tokyo Metropolitan Inst Publ Hlth, Dept Environm Hlth & Toxicol, Div Environm Hlth, Tokyo, Japan
[5] Asahikawa Med Univ, Dept Hlth Sci, Asahikawa, Hokkaido, Japan
关键词
Sick house syndrome; Indoor chemicals; Biological factors; Dampness; Dwelling; BUILDING SYNDROME SBS; MITE ALLERGEN LEVELS; JAPANESE DWELLINGS; FLOOR CONSTRUCTION; ORGANIC-COMPOUNDS; FLAME RETARDANTS; DUST MITE; EXPOSURE; SYMPTOMS; ASTHMA;
D O I
10.1016/j.buildenv.2018.03.056
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Sick house syndrome (SHS) derived from sick building syndrome (SBS) is used to describe symptoms that inhabitants experience due to indoor environment and personal factors, and children might be more susceptible to the effects of SHS than adults. However, there have been no comprehensive studies on effects of indoor pollutants exposure in relation to SHS. Thus, the aim of this study is to examine the association between indoor pollutants and SHS in children and adults who live in the same dwelling. This is a cross-sectional study on 184 elementary school children and 273 adults/adolescents in Sapporo, Japan. Indoor pollutants were measured in air and dust collected from 128 dwellings. Results showed children (20.6%) have higher prevalence of any symptoms than adults/adolescents (15.1%). Among SHS, mucosal symptoms were the most common in both children and adults/adolescents. Doctor diagnosed allergies, building age, dampness, and ventilation system showed significant association with prevalence of SHS. Formaldehyde, di(isobutyl) phthalate (DiBP), di(2-ethylhexyl) phthalate (DEHP), di(isononyl) phthalate (DiNP), endotoxin, and 13-glucan were detected in all dwellings. Any symptoms and mucosal symptoms were significantly associated with the exposure to 2-ethyl-1-hexanol (2E1H). Floor dust DiNP, multi-surface dust Tris(2-butoxyethyl) phosphate with mucosal symptoms and endotoxin with dermal symptoms were inversely associated in adults/adolescent. Multi-surface dust DiBP also showed inverse association with mucosal symptoms in children. 2E1H emission increased with dampness in the dwellings thus, eliminating dampness in the dwellings may reduce the emissions of 2E1H and the risk of SHS in residents.
引用
收藏
页码:293 / 301
页数:9
相关论文
共 45 条
[1]  
Abb M., 2009, ENVIRON INT, V35, P65
[2]  
Andersson K, 1998, INDOOR AIR, P32
[3]  
[Anonymous], SCI TOTAL ENV
[4]  
[Anonymous], 2012, TOXIC ASSESS, DOI DOI 10.2772/21444
[5]   Phosphorus flame retardants in indoor dust and their relation to asthma and allergies of [J].
Araki, A. ;
Saito, I. ;
Kanazawa, A. ;
Morimoto, K. ;
Nakayama, K. ;
Shibata, E. ;
Tanaka, M. ;
Takigawa, T. ;
Yoshimura, T. ;
Chikara, H. ;
Saijo, Y. ;
Kishi, R. .
INDOOR AIR, 2014, 24 (01) :3-15
[6]   Diffusive sampling and measurement of microbial volatile organic compounds in indoor air [J].
Araki, A. ;
Eitaki, Y. ;
Kawai, T. ;
Kanazawa, A. ;
Takeda, M. ;
Kishi, R. .
INDOOR AIR, 2009, 19 (05) :421-432
[7]   The relationship between exposure to microbial volatile organic compound and allergy prevalence in single-family homes [J].
Araki, Atsuko ;
Kanazawa, Ayako ;
Kawai, Toshio ;
Eitaki, Yoko ;
Morimoto, Kanehisa ;
Nakayama, Kunio ;
Shibata, Eiji ;
Tanaka, Masatoshi ;
Takigawa, Tomoko ;
Yoshimura, Takesumi ;
Chikara, Hisao ;
Saijo, Yasuaki ;
Kishi, Reiko .
SCIENCE OF THE TOTAL ENVIRONMENT, 2012, 423 :18-26
[8]   Relationship between selected indoor volatile organic compounds, so-called microbial VOC, and the prevalence of mucous membrane symptoms in single family homes [J].
Araki, Atsuko ;
Kawai, Toshio ;
Eitaki, Yoko ;
Kanazawa, Ayako ;
Morimoto, Kanehisa ;
Nakayama, Kunio ;
Shibata, Eiji ;
Tanaka, Masatoshi ;
Takigawa, Tomoko ;
Yoshimura, Takesumi ;
Chikara, Hisao ;
Saijo, Yasuaki ;
Kishi, Reiko .
SCIENCE OF THE TOTAL ENVIRONMENT, 2010, 408 (10) :2208-2215
[9]  
Bamai Y. Ait, 2016, ENVIRON INT, V96, P6
[10]   Exposure to house dust phthalates in relation to asthma and allergies in both children and adults [J].
Bamai, Yu Ait ;
Shibata, Eiji ;
Saito, Ikue ;
Araki, Atsuko ;
Kanazawa, Ayako ;
Morimoto, Kanehisa ;
Nakayama, Kunio ;
Tanaka, Masatoshi ;
Takigawa, Tomoko ;
Yoshimura, Takesumi ;
Chikara, Hisao ;
Saijo, Yasuaki ;
Kishi, Reiko .
SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 485 :153-163