Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays

被引:1725
作者
Sodickson, DK
Manning, WJ
机构
[1] CHARLES A DANA RES INST, BOSTON, MA 02215 USA
[2] BETH ISRAEL DEACONESS MED CTR, DEPT RADIOL, BOSTON, MA USA
[3] HARVARD UNIV, SCH MED, BOSTON, MA USA
关键词
fast imaging; RF coil array; simultaneous acquisition; MR image reconstruction;
D O I
10.1002/mrm.1910380414
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SiMultaneous Acquisition of Spatial Harmonics (SMASH) is a new fast-imaging technique that increases MR image acquisition speed by an integer factor over existing fast-imaging methods, without significant sacrifices in spatial resolution or signal-to-noise ratio. Image acquisition time is reduced by exploiting spatial information inherent in the geometry of a surface coil array to substitute for some of the phase encoding usually produced by magnetic field gradients. This allows for partially parallel image acquisitions using many of the existing fast-imaging sequences. Unlike the data combination algorithms of prior proposals for parallel imaging, SMASH reconstruction involves a small set of MR signal combinations prior to Fourier transformation, which can be advantageous for artifact handling and practical implementation. A twofold savings in image acquisition time is demonstrated here using commercial phased array coils on two different MR-imaging systems. Larger time savings factors can be expected for appropriate coil designs.
引用
收藏
页码:591 / 603
页数:13
相关论文
共 21 条
  • [1] HIGH-SPEED SPIRAL-SCAN ECHO PLANAR NMR IMAGING .1.
    AHN, CB
    KIM, JH
    CHO, ZH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) : 2 - 7
  • [2] AHN CB, 1985, P SMRM 4 ANN M, P935
  • [3] IMAGING TIME REDUCTION THROUGH MULTIPLE RECEIVER COIL DATA ACQUISITION AND IMAGE-RECONSTRUCTION
    CARLSON, JW
    MINEMURA, T
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (05) : 681 - 688
  • [4] THE RICIAN DISTRIBUTION OF NOISY MRI DATA
    GUDBJARTSSON, H
    PATZ, S
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) : 910 - 914
  • [5] VOLUME IMAGING WITH MR PHASED-ARRAYS
    HAYES, CE
    HATTES, N
    ROEMER, PB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) : 309 - 319
  • [6] HAYES CE, 1990, MAGNET RESON MED, V16, P151
  • [7] RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR
    HENNIG, J
    NAUERTH, A
    FRIEDBURG, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) : 823 - 833
  • [8] Hennig J., 1993, MAGMA, V1, P39, DOI 10.1007/BF02660372
  • [9] HENNIG J, 1988, 7TH P SMRM ANN M SAN, P238
  • [10] SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT
    HOULT, DI
    RICHARDS, RE
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1976, 24 (01) : 71 - 85