Biomechanical evaluation of fixation strength among different sizes of pedicle screws using the cortical bone trajectory: what is the ideal screw size for optimal fixation?

被引:85
作者
Matsukawa, Keitaro [1 ]
Yato, Yoshiyuki [2 ]
Imabayashi, Hideaki [1 ]
Hosogane, Naobumi [1 ]
Abe, Yuichiro [3 ]
Asazuma, Takashi [2 ]
Chiba, Kazuhiro [1 ]
机构
[1] Natl Def Med Coll, Dept Orthopaed Surg, Tokorozawa, Saitama 359, Japan
[2] Natl Hosp Org, Murayama Med Ctr, Dept Orthopaed Surg, Musashimurayama, Tokyo, Japan
[3] Wajokai Eniwa Hosp, Dept Orthopaed Surg, Eniwa, Hokkaido, Japan
关键词
Cortical bone trajectory; Lumbar pedicle screw; Screwsize; Pullout strength; Fixation strength; Finite element method; LUMBAR PEDICLE; LOADS;
D O I
10.1007/s00701-016-2705-8
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The cortical bone trajectory (CBT) has attracted attention as a new minimally invasive technique for lumbar instrumentation by minimizing soft-tissue dissection. Biomechanical studies have demonstrated the superior fixation capacity of CBT; however, there is little consensus on the selection of screw size, and no biomechanical study has elucidated the most suitable screw size for CBT. The purpose of the present study was to evaluate the effect of screw size on fixation strength and to clarify the ideal size for optimal fixation using CBT. A total of 720 analyses on CBT screws with various diameters (4.5-6.5 mm) and lengths (25-40 mm) in simulations of 20 different lumbar vertebrae (mean age: 62.1 +/- 20.0 years, 8 males and 12 females) were performed using a finite element method. First, the fixation strength of a single screw was evaluated by measuring the axial pullout strength. Next, the vertebral fixation strength of a paired-screw construct was examined by applying forces simulating flexion, extension, lateral bending, and axial rotation to the vertebra. Lastly, the equivalent stress value of the bone-screw interface was calculated. Larger-diameter screws increased the pullout strength and vertebral fixation strength and decreased the equivalent stress around the screws; however, there were no statistically significant differences between 5.5-mm and 6.5-mm screws. The screw diameter was a factor more strongly affecting the fixation strength of CBT than the screw fit within the pedicle (%fill). Longer screws significantly increased the pullout strength and vertebral fixation strength in axial rotation. The amount of screw length within the vertebral body (%length) was more important than the actual screw length, contributing to the vertebral fixation strength and distribution of stress loaded to the vertebra. The fixation strength of CBT screws varied depending on screw size. The ideal screw size for CBT is a diameter larger than 5.5 mm and length longer than 35 mm, and the screw should be placed sufficiently deep into the vertebral body.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 30 条
[1]   Effect of Physiological Loads on Cortical and Traditional Pedicle Screw Fixation [J].
Baluch, Daniel A. ;
Patel, Alpesh A. ;
Lullo, Brett ;
Havey, Robert M. ;
Voronov, Leonard I. ;
Ngoc-Lam Nguyen ;
Carandang, Gerard ;
Ghanayem, Alexander J. ;
Patwardhan, Avinash G. .
SPINE, 2014, 39 (22) :E1297-E1302
[2]   Minimizing Pedicle Screw Pullout Risks A Detailed Biomechanical Analysis of Screw Design and Placement [J].
Bianco, Rohan-Jean ;
Arnoux, Pierre-Jean ;
Wagnac, Eric ;
Mac-Thiong, Jean-Marc ;
Aubin, Carl-Eric .
CLINICAL SPINE SURGERY, 2017, 30 (03) :E226-E232
[3]   THE EFFECTS OF PEDICLE SCREW FIT - AN IN-VITRO STUDY [J].
BRANTLEY, AGU ;
MAYFIELD, JK ;
KOENEMAN, JB ;
CLARK, KR .
SPINE, 1994, 19 (15) :1752-1758
[4]   Biomechanical investigation of pedicle screw-vertebrae complex: a finite element approach using bonded and contact interface conditions [J].
Chen, SI ;
Lin, RM ;
Chang, CH .
MEDICAL ENGINEERING & PHYSICS, 2003, 25 (04) :275-282
[5]   COMPUTED TOMOGRAPHIC OSTEOMETRY OF ASIAN LUMBAR PEDICLES [J].
CHEUNG, KMC ;
RUAN, D ;
CHAN, FL ;
FANG, D .
SPINE, 1994, 19 (13) :1495-1498
[6]   EFFECTS OF BONE-MINERAL DENSITY ON PEDICLE SCREW FIXATION [J].
HALVORSON, TL ;
KELLEY, LA ;
THOMAS, KA ;
WHITECLOUD, TS ;
COOK, SD .
SPINE, 1994, 19 (21) :2415-2420
[7]   Structural characteristics of the pedicle and its role in screw stability [J].
Hirano, T ;
Hasegawa, K ;
Takahashi, HE ;
Uchiyama, S ;
Hara, T ;
Washio, T ;
Sugiura, T ;
Yokaichiya, M ;
Ikeda, M .
SPINE, 1997, 22 (21) :2504-2509
[8]   Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses [J].
Hsu, CC ;
Chao, CK ;
Wang, JL ;
Hou, SM ;
Tsai, YT ;
Lin, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (04) :788-794
[9]   Nonlinear finite element model predicts vertebral bone strength and fracture site [J].
Imai, Kazuhiro ;
Ohnishi, Isao ;
Bessho, Masahiko ;
Nakamura, Kozo .
SPINE, 2006, 31 (16) :1789-1794
[10]  
Karami KJ, 2015, J SPINAL DISORD TECH, V28, pE133, DOI 10.1097/BSD.0000000000000178