Comparison of Thermal and Electrical Modalities in the Assessment of Temporal Summation of Pain and Conditioned Pain Modulation

被引:2
作者
Sean, Monica [1 ]
Coulombe-Leveque, Alexia [1 ]
Bordeleau, Martine [1 ]
Vincenot, Matthieu [1 ]
Gendron, Louis [2 ]
Marchand, Serge [3 ]
Leonard, Guillaume [1 ]
机构
[1] Univ Sherbrooke, Fac Med & Hlth Sci, Res Ctr Aging, Sch Rehabil, Sherbrooke, PQ, Canada
[2] Univ Sherbrooke, Fac Med & Hlth Sci, Dept Pharmacol Physiol, Sherbrooke, PQ, Canada
[3] Univ Sherbrooke, Fac Med & Hlth Sci, Dept Neurosurg, Sherbrooke, PQ, Canada
来源
FRONTIERS IN PAIN RESEARCH | 2021年 / 2卷
基金
加拿大健康研究院;
关键词
pain; transcutaneous electrical nerve stimulation; thermode; cold pressor test; conditioned pain modulation; temporal summation of pain; dynamic quantitative sensory testing; 2ND PAIN; FIBROMYALGIA; STIMULATION; SENSITIZATION; MECHANISMS;
D O I
10.3389/fpain.2021.659563
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Temporal summation of pain (TSP) and conditioned pain modulation (CPM) can be measured using a thermode and a cold pressor test (CPT). Unfortunately, these tools are complex, expensive, and are ill-suited for routine clinical assessments. Building on the results from an exploratory study that attempted to use transcutaneous electrical nerve stimulation (TENS) to measure CPM and TSP, the present study assesses whether a "new" TENS protocol can be used instead of the thermode and CPT to measure CPM and TSP. The objective of this study was to compare the thermode/CPT protocol with the new TENS protocol, by (1) measuring the association between the TSP evoked by the two protocols; (2) measuring the association between the CPM evoked by the two protocols; and by (3) assessing whether the two protocols successfully trigger TSP and CPM in a similar number of participants. We assessed TSP and CPM in 50 healthy participants, using our new TENS protocol and a thermode/CPT protocol (repeated measures and randomized order). In the TENS protocol, both the test stimulus (TS) and the conditioning stimulus (CS) were delivered using TENS; in the thermode/CPT protocol, the TS was delivered using a thermode and the CS consisted of a CPT. There was no association between the response evoked by the two protocols, neither for TSP nor for CPM. The number of participants showing TSP [49 with TENS and 29 with thermode (p < 0.001)] and CPM [16 with TENS and 30 with thermode (p = 0.01)] was different in both protocols. Our results suggest that response to one modality does not predict response to the other; as such, TENS cannot be used instead of a thermode/CPT protocol to assess TSP and CPM without significantly affecting the results. Moreover, while at first glance it appears that TENS is more effective than the thermode/CPT protocol to induce TSP, but less so to induce CPM, these results should be interpreted carefully. Indeed, TSP and CPM response appear to be modality-dependent as opposed to an absolute phenomenon, and the two protocols may tap into entirely different mechanisms, especially in the case of TSP.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] A possible mechanism underlying conditioned pain modulation
    King, Christopher D.
    [J]. PAIN, 2014, 155 (06) : 1047 - 1048
  • [32] Oxycodone alters temporal summation but not conditioned pain modulation: Preclinical findings and possible relations to mechanisms of opioid analgesia
    Suzan, Erica
    Midbari, Ayelet
    Treister, Roi
    Haddad, May
    Pud, Dorit
    Eisenberg, Elon
    [J]. PAIN, 2013, 154 (08) : 1413 - 1418
  • [33] Reliability and minimal detectable change of dynamic temporal summation and conditioned pain modulation using a single experimental paradigm
    Vincenot, Matthieu
    Beaulieu, Louis-David
    Gendron, Louis
    Marchand, Serge
    Leonard, Guillaume
    [J]. PLOS ONE, 2024, 19 (07):
  • [34] Electrical (Pain) Thresholds and Conditioned Pain Modulation in Patients with Low Back-Related Leg Pain and Patients with Failed Back Surgery Syndrome: A Cross-Sectional Pilot Study
    Goudman, Lisa
    Huysmans, Eva
    Coppieters, Iris
    Ickmans, Kelly
    Nijs, Jo
    Buyl, Ronald
    Putman, Koen
    Moens, Maarten
    [J]. PAIN MEDICINE, 2020, 21 (03) : 538 - 547
  • [35] Temporal stability of conditioned pain modulation in healthy women over four menstrual cycles at the follicular and luteal phases
    Wilson, Hilary
    Carvalho, Brendan
    Granot, Michal
    Landau, Ruth
    [J]. PAIN, 2013, 154 (12) : 2633 - 2638
  • [36] IMPACT OF MUSIC ON FIRST PAIN AND TEMPORAL SUMMATION OF SECOND PAIN: A PSYCHOPHYSICAL PILOT STUDY
    Cabon, Mathilde
    le Fur-Bonnabesse, Anais
    Genestet, Steeve
    Quinio, Bertrand
    Misery, Laurent
    Woda, Alain
    Bodere, Celine
    [J]. MUSIC PERCEPTION, 2021, 38 (03): : 267 - 281
  • [37] The Effect of Conditioned Pain Modulation on Tonic Heat Pain Assessed Using Participant-Controlled Temperature
    Sirucek, Laura
    Jutzeler, Catherine Ruth
    Rosner, Jan
    Schweinhardt, Petra
    Curt, Armin
    Kramer, John Lawrence Kipling
    Hubli, Michele
    [J]. PAIN MEDICINE, 2020, 21 (11) : 2839 - 2849
  • [38] Psychophysical testing of spatial and temporal dimensions of endogenous analgesia: conditioned pain modulation and offset analgesia
    Honigman, Liat
    Yarnitsky, David
    Sprecher, Elliot
    Weissman-Fogel, Irit
    [J]. EXPERIMENTAL BRAIN RESEARCH, 2013, 228 (04) : 493 - 501
  • [39] Conditioned pain modulation in temporomandibular disorders (TMD) pain patients
    Oono, Yuka
    Wang, Kelun
    Baad-Hansen, Lene
    Futarmal, Simple
    Kohase, Hikaru
    Svensson, Peter
    Arendt-Nielsen, Lars
    [J]. EXPERIMENTAL BRAIN RESEARCH, 2014, 232 (10) : 3111 - 3119
  • [40] Reference values of conditioned pain modulation
    Schliessbach, Juerg
    Luetolf, Christian
    Streitberger, Konrad
    Scaramozzino, Pasquale
    Arendt-Nielsen, Lars
    Curatolo, Michele
    [J]. SCANDINAVIAN JOURNAL OF PAIN, 2019, 19 (02) : 279 - 286