An aggregation-induced emission (AIE) ratiometric fluorescent cysteine probe with an exceptionally large blue shift

被引:25
|
作者
Yan, Liqiang [1 ]
Kong, Zhineng [1 ]
Shen, Wei [1 ]
Du, Wenqi [1 ]
Zhou, Yan [1 ]
Qi, Zhengjian [1 ]
机构
[1] Southeast Univ, Coll Chem & Chem Engn, Nanjing 211189, Jiangsu, Peoples R China
来源
RSC ADVANCES | 2016年 / 6卷 / 07期
关键词
SELECTIVE DETECTION; HOMOCYSTEINE; MITOCHONDRIA; PLASMA; THIOLS; SENSOR; CELLS;
D O I
10.1039/c5ra22245a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, we developed a novel colorimetric and ratiometric fluorescence probe for the selective and sensitive monitoring of cysteine based on a coumarin Schiff-base platform. This probe exhibited remarkable AIE characteristics with an exceptionally large blue shift (125 nm), which showed low emission in DMSO but strong aggregation-induced emission in water solution. An excellent linear relationship of fluorescence intensity ratio (F-450/F-575) (R-2 = 0.9922) versus Cys concentration in the range of 1-13 mu M was obtained.
引用
收藏
页码:5636 / 5640
页数:5
相关论文
共 50 条
  • [1] A diazabenzoperylene derivative as ratiometric fluorescent probe for cysteine with super large Stokes shift
    Wang, Shuo
    Zhang, Qi
    Chen, Shaojin
    Wang, Kun-Peng
    Hu, Zhi-Qiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (11) : 2687 - 2696
  • [2] A highly sensitive ratiometric fluorescent probe with a large emission shift for imaging endogenous cysteine in living cells
    Zhu, Baocun
    Guo, Bingpeng
    Zhao, Yunzhou
    Zhang, Bing
    Du, Bin
    BIOSENSORS & BIOELECTRONICS, 2014, 55 : 72 - 75
  • [3] A fluorescent probe with aggregation-induced emission characteristics for distinguishing homocysteine over cysteine and glutathione
    Zhao, Na
    Gong, Qian
    Zhang, Rui Xue
    Yang, Jun
    Huang, Zhi Yan
    Li, Nan
    Tang, Ben Zhong
    JOURNAL OF MATERIALS CHEMISTRY C, 2015, 3 (32) : 8397 - 8402
  • [4] An endoplasmic reticulum-targeted ratiometric fluorescent probe for hypochlorite bioimaging based on aggregation-induced ratiometric emission
    Chang, Xiao-Chuang
    Zhang, Ling
    Liu, Bing-Jie
    Lou, Yan-Tao
    Xu, Wei-Fan
    Li, Xin-Ru
    Han, Xue-Feng
    Wu, Wei-Na
    Wang, Yuan
    Xu, Zhi-Hong
    MICROCHEMICAL JOURNAL, 2023, 191
  • [5] A novel ratiometric fluorescent probe through aggregation-induced emission and analyte-induced excimer dissociation
    Xie, Huafei
    Jiang, Xiaohui
    Zeng, Fang
    Yu, Changmin
    Wu, Shuizhu
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 203 : 504 - 510
  • [6] A responsive aggregation-induced emission fluorescent probe for the detection of cysteine in food, serum samples and oxidative stress environments
    Gong, Minggui
    Su, Jiajie
    Chen, Ying
    Zheng, Kaixin
    Yuan, Lijie
    Qin, Fangyuan
    Niu, Huawei
    Ye, Yong
    MICROCHEMICAL JOURNAL, 2024, 206
  • [7] Ratiometric fluorescent detection of hypochlorite in aqueous solution and living cells using an ionic probe with aggregation-induced emission feature
    Yuan, Yiyang
    Wang, Deqiang
    Long, Wei
    Deng, Fengjie
    Yu, Shengxian
    Tian, Jianwen
    Ouyang, Hui
    Lin, Sen
    Zhang, Xiaoyong
    Wei, Yen
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 330
  • [8] A highly selective ratiometric fluorescent probe for hydrogen peroxide displaying a large emission shift
    Zhu, Baocun
    Jiang, Houlin
    Guo, Bingpeng
    Shao, Changxiang
    Wu, Huifang
    Du, Bin
    Wei, Qin
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 186 : 681 - 686
  • [9] Aggregation-Induced Emission (AIE) Probes in Fluorescent Sensing: Progress and Applications for Pesticide Detection
    Zha, Bowen
    Li, Hui
    Ren, Susu
    Wu, Jia-Rui
    Wang, Haitao
    APPLIED SCIENCES-BASEL, 2024, 14 (19):
  • [10] An aggregation-induced emission (AIE) fluorescent chemosensor for the detection of Al(III) in aqueous solution
    Li, Yuanyuan
    Xu, Kui
    Si, Yue
    Yang, Cuiping
    Peng, Qiuchen
    He, Juan
    Hu, Qinggang
    Li, Kai
    DYES AND PIGMENTS, 2019, 171