Dispersive micro solid-phase extraction of heavy metals as their complexes with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol using graphene oxide nanoparticles

被引:40
作者
Pytlakowska, Katarzyna [1 ]
机构
[1] Silesian Univ, Inst Chem, PL-40006 Katowice, Poland
关键词
Graphene oxide; Dispersive micro solid-phase extraction; Microextraction; Energy dispersive X-ray fluorescence spectrometry; Preconcentration; ATOMIC-ABSORPTION-SPECTROMETRY; MULTIWALLED CARBON NANOTUBES; RAY-FLUORESCENCE SPECTROMETRY; TRACE-ELEMENTS; EMISSION-SPECTROMETRY; WATER SAMPLES; FOOD SAMPLES; PRECONCENTRATION; IONS; SORBENT;
D O I
10.1007/s00604-015-1596-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article describes a new procedure for multi-element preconcentration of heavy metal ions, specifically of Cr(III), Co(II), Ni(II), Cu(II), Zn(II) and Pb(II) ions. The method is based on dispersive micro solid-phase extraction (DMSPE) of the metal complexes of 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) by graphene oxide nanoparticles prior to energy dispersive X-ray fluorescence spectrometric (EDXRF) determination. The effects of pH, amount of graphene oxide, concentration of complexing reagent, sample volume and sorption time were optimized. The influence of commonly encountered other ions was also investigated. Under optimal conditions, the calibration plots cover the 2 to 150 ng mL(-1) range for each element. The precision (at a 20 ng mL(-1) level for n = 10) is lower than 4.8 %, and the detection limits range is from 0.07 to 0.25 ng mL(-1). The DMSPE-EDXRF procedure was successfully applied to the determination of heavy metal ions in water and spiked water samples with recoveries between 94.4 and 103.5 %.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 36 条
  • [1] ALO ZA, 2012, MICROCHIM ACTA, V177, P397
  • [2] Anastassiades M, 2003, J AOAC INT, V86, P412
  • [3] [Anonymous], 11885 ISO
  • [4] A review on procedures for the preparation of coatings for solid phase microextraction
    Aziz-Zanjani, Mohammad Ovais
    Mehdinia, Ali
    [J]. MICROCHIMICA ACTA, 2014, 181 (11-12) : 1169 - 1190
  • [5] Application of graphene as a sorbent for preconcentration and determination of trace amounts of chromium(III) in water samples by flame atomic absorption spectrometry
    Chang, Qingyun
    Song, Shuangju
    Wang, Yukun
    Li, Jingci
    Ma, Jingjun
    [J]. ANALYTICAL METHODS, 2012, 4 (04) : 1110 - 1116
  • [6] Solid-phase extraction of Cu, Co and Pb on oxidized single-walled carbon nanotubes and their determination by inductively coupled plasma mass spectrometry
    Chen, Shizhong
    Liu, Cheng
    Yang, Ming
    Lu, Dengbo
    Zhu, Li
    Wang, Zhan
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2009, 170 (01) : 247 - 251
  • [7] Nanometer-sized ceria-coated silica-iron oxide for the reagentless microextraction/preconcentration of heavy metals in environmental and biological samples followed by slurry introduction to ICP-OES
    Dados, A.
    Paparizou, E.
    Eleftheriou, P.
    Papastephanou, C.
    Stalikas, C. D.
    [J]. TALANTA, 2014, 121 : 127 - 135
  • [8] Preconcentration of some trace elements via using multiwalled carbon nanotubes as solid phase extraction adsorbent
    Duran, Ali
    Tuzen, Mustafa
    Soylak, Mustafa
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2009, 169 (1-3) : 466 - 471
  • [9] A nanoparticle-based solid-phase extraction procedure followed by flow injection inductively coupled plasma-optical emission spectrometry to determine some heavy metal ions in water samples
    Faraji, Mohammad
    Yamini, Yadollah
    Saleh, Abolfazl
    Rezaee, Mohammad
    Ghambarian, Mahnaz
    Hassani, Rahim
    [J]. ANALYTICA CHIMICA ACTA, 2010, 659 (1-2) : 172 - 177
  • [10] Determination of trace elements in food samples by ICP-AES after preconcentration with p-toluenesulfonylamide immobilized on silica gel and nanometer SiO2
    He, Qun
    Chang, Xijun
    Huang, Xinping
    Hu, Zheng
    [J]. MICROCHIMICA ACTA, 2008, 160 (1-2) : 147 - 152