Mechanical behavior of spiral stirrup reinforced concrete filled square steel tubular columns under compression

被引:51
作者
Chen, Zongping [1 ,2 ]
Zhou, Ji [1 ]
Jing, Chenggui [3 ]
Tan, Qiuhong [1 ]
机构
[1] Guangxi Univ, Coll Civil Engn & Architecture, Nanning 530004, Peoples R China
[2] Guangxi Univ, Key Lab Disaster Prevent & Struct Safety, Chinese Minist Educ, Nanning 530004, Peoples R China
[3] Guangxi Univ Sci & Techonol, Sch Civil Bldg Engn, Liuzhou 545006, Peoples R China
关键词
Concrete-filled square steel tube; Spiral stirrup; Compressive behavior; Composite confine model; Ultimate bearing capacity; AXIAL LOAD BEHAVIOR; STUB COLUMNS; BOX COLUMNS; STRENGTH;
D O I
10.1016/j.engstruct.2020.111377
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Stirrup-confined concrete-filled square steel tubular (CFSST) columns with spiral stirrup alleviates the local buckling of square steel tube, thereby improving both ultimate bearing capacity and ductility. This paper presents an experimental study on compressive behavior of spiral stirrup reinforced concrete-filled square steel tubular (SSRCFSST) columns. Twenty-nine axial compression specimens and eighteen eccentric compression specimens were tested for experimental investigation of the effects of the sample size, the concrete strength, the thickness of steel tube, the ratio of diameter to width, the spacing of spiral stirrup and the steel ratio. In addition, the effect of eccentricity ratio on the eccentric compression specimens was also investigated. The test results show that the spiral stirrup has excellent cooperation ability with square steel tube and concrete, can effectively improve the non-uniform confine of square steel tube and enhance the confine effect on concrete. Furthermore, decreasing the spacing of spiral stirrup can enhance the axial bearing capacity and ductility of SSRCFSST columns, but has little effect on the eccentric bearing capacity. A composite model confined by square steel tube and spiral stirrup is established, the calculation formulas to estimate the bearing capacity of SSRCFSST columns are developed and close correlations are found between the calculated results and the experimental results.
引用
收藏
页数:19
相关论文
共 39 条
[1]  
[Anonymous], 2013, 500812002 GBT
[2]  
[Anonymous], 2010, 5000102010 GB
[3]  
[Anonymous], 2014, GB 50936-2014
[4]   Dynamic analysis of concrete column reinforced with Sio2 nanoparticles subjected to blast load [J].
Azmi, Masoud ;
Kolahchi, Reza ;
Bidgoli, Mahmood Rabani .
ADVANCES IN CONCRETE CONSTRUCTION, 2019, 7 (01) :51-63
[5]   Axial load behavior of square CFT stub column with binding bars [J].
Cai, J ;
He, ZQ .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (05) :472-483
[6]  
Cao M, 2013, MECH ANAL SQUARE CON
[7]  
[陈志华 Chen Zhihua], 2015, [建筑结构, Building Structure], V45, P28
[8]  
China C., 2019, 1592004 CECS, V624
[9]   Behavior of steel-reinforced concrete-filled square steel tubular stub columns under axial loading [J].
Ding, Fa-xing ;
Zhang, Tao ;
Liu, Xue-mei ;
Lu, Zhao-Hui ;
Guo, Qiang ;
Jiang, Guo-shuai .
THIN-WALLED STRUCTURES, 2017, 119 :737-748
[10]   Mechanical performance of stirrup-confined concrete-filled steel tubular stub columns under axial loading [J].
Ding, Fa-xing ;
Fang, Changjing ;
Bai, Yu ;
Gong, Yong-zhi .